Evaluation of anterior segment parameters with two anterior segment optical coherence tomography systems: Visante and Casia, in primary angle closure disease

被引:10
作者
Angmo, Dewang [1 ]
Singh, Reena [1 ]
Chaurasia, Shweta [1 ]
Yadav, Suresh [1 ]
Dada, Tanuj [1 ]
机构
[1] All India Inst Med Sci, Dept Ophthalmol, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Res & Clin Facil, New Delhi, India
关键词
Angle parameters; anterior segment optical coherence tomography machines; Casia ASOCT; comparison; FD-OCT; primary angle closure disease; Visante ASOCTSS-OCT; SCLERAL SPUR; GLAUCOMA; EYES;
D O I
10.4103/ijo.IJO_641_18
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To determine the comparability of anterior chamber biometric measurements in primary angle closure disease (PACD) patients using two commercially available anterior segment optical coherence tomography machines (ASOCT): Visante and Casia. Methods: This was a cross-sectional observational study, which included clinically, diagnosed cases of PACD. Anterior segment biometric measurements were done using Casia and Visante ASOCT. Parameters studied were central corneal thickness (CCT), anterior chamber depth (ACD), nasal (N) and temporal (1) angle opening distance at 500 mu m (AOD500) and 750 mu m (AOD750), and N and T trabecular iris space area at 500 mu m (TISA500) and 750 mu m (TIM 750). Results. Total 36 PACD patients (72 eyes) with average age of 59.48 +/- 7.95 years were recruited, out of which 25 were females (69.44%) and 11 males (30.56%). The mean measurements of CCT, ACD, AOD500, and TISA on Casia and Visante machines were 522.5 +/- 34.75 mu m and 539.55 +/- 29.56 mu m (P = 0.00); ACD- 2.144 +/- 0.38 mu m and 2.133 +/- 0.39 mu m (P = 0.487); AOD500-0.27 +/- 0.16 mu m and 0.21 +/- 0.10 mu m (P = 0.04); and TISA500-0.100 +/- 0.07 mu m and 0.063 +/- 0.03 mu m (P = 0.00), respectively. A statistically significant difference was noted in CCT, N and T AOD, and TISA. A good corelation for ACD and CCT (ACD = 0.9816 and CCT = 0.772) only were noted between the two machines. The Bland-Altman plot analysis of different parameters between two machines has revealed good agreement of measurement of ACD and CCT but poor agreement for rest of the parameters. Conclusion: It is advisable not use the two machines interchangeably because of the wide limits of agreement and poor correlation of angle measurement values of Casia and Visante ASOCT.
引用
收藏
页码:500 / 504
页数:5
相关论文
共 50 条
  • [21] Evaluation of the effects of selective laser trabeculoplasty on anterior segment parameters by anterior segment optical coherence tomography
    Murat Atabey Özer
    Tevfik Oğurel
    Serkan Özen
    Yaşar Küçüksümer
    Lasers in Medical Science, 2020, 35 : 1271 - 1275
  • [22] Comparison of Anterior Segment-Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes
    Moghimi, Sasan
    Ramezani, Farshid
    He, Mingguang
    Coleman, Anne L.
    Lin, Shan C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (13) : 7611 - 7617
  • [23] Outcomes of Laser Peripheral Iridotomy in Angle Closure Subgroups According to Anterior Segment Optical Coherence Tomography Parameters
    Han, Seungbong
    Sung, Kyung Rim
    Lee, Kyoung Sub
    Hong, Ji Wook
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) : 6795 - 6801
  • [24] Deep Learning-Based Classification of Subtypes of Primary Angle-Closure Disease With Anterior Segment Optical Coherence Tomography
    Eslami, Yadollah
    Mousavi Kouzahkanan, Zahra
    Farzinvash, Zahra
    Safizadeh, Mona
    Zarei, Reza
    Fakhraie, Ghasem
    Vahedian, Zakieh
    Mahmoudi, Tahereh
    Fadakar, Kaveh
    Beikmarzehei, Alireza
    Tabatabaei, Seyed Mehdi
    JOURNAL OF GLAUCOMA, 2023, 32 (06) : 540 - 547
  • [25] Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography
    Khor, Wei-Boon
    Sakata, Lisandro M.
    Friedman, David S.
    Narayanaswamy, Arun
    Lavanya, Raghavan
    Perera, Shamira A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2010, 19 (06) : 365 - 368
  • [26] The anterior and posterior biometric characteristics in primary angle-closure disease: Data based on anterior segment optical coherence tomography and swept-source optical coherence tomography
    Huang, Wenbin
    Li, Xingyi
    Gao, Xinbo
    Zhang, Xiulan
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (04) : 865 - 870
  • [27] Evaluation of meridional scans for angle closure assessment with anterior segment swept-source optical coherence tomography
    Porporato, Natalia
    Baskaran, Mani
    Perera, Shamira
    Tun, Tin A.
    Sultana, Rehena
    Tan, Marcus
    Quah, Joanne HuiMin
    Allen, John C.
    Friedman, David
    Cheng, Ching Yu
    Aung, Tin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (01) : 131 - 134
  • [28] Assessment of angle closure spectrum disease as a continuum of change using gonioscopy and anterior segment optical coherence tomography
    Phu, Jack
    Wong, Brian
    Lim, Thalia
    Kalloniatis, Michael
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2020, 40 (05) : 617 - 631
  • [29] Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma
    Palanisamy, Sreeramyaa
    Raja, Vidya
    Senthilkumar, Vijayalakshmi A.
    Mani, Iswarya
    Krishnadas, R.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2895 - 2901
  • [30] Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure
    Mansouri, K.
    Sommerhalder, J.
    Shaarawy, T.
    EYE, 2010, 24 (02) : 233 - 239