Evaluation of anterior segment parameters with two anterior segment optical coherence tomography systems: Visante and Casia, in primary angle closure disease

被引:10
作者
Angmo, Dewang [1 ]
Singh, Reena [1 ]
Chaurasia, Shweta [1 ]
Yadav, Suresh [1 ]
Dada, Tanuj [1 ]
机构
[1] All India Inst Med Sci, Dept Ophthalmol, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Res & Clin Facil, New Delhi, India
关键词
Angle parameters; anterior segment optical coherence tomography machines; Casia ASOCT; comparison; FD-OCT; primary angle closure disease; Visante ASOCTSS-OCT; SCLERAL SPUR; GLAUCOMA; EYES;
D O I
10.4103/ijo.IJO_641_18
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To determine the comparability of anterior chamber biometric measurements in primary angle closure disease (PACD) patients using two commercially available anterior segment optical coherence tomography machines (ASOCT): Visante and Casia. Methods: This was a cross-sectional observational study, which included clinically, diagnosed cases of PACD. Anterior segment biometric measurements were done using Casia and Visante ASOCT. Parameters studied were central corneal thickness (CCT), anterior chamber depth (ACD), nasal (N) and temporal (1) angle opening distance at 500 mu m (AOD500) and 750 mu m (AOD750), and N and T trabecular iris space area at 500 mu m (TISA500) and 750 mu m (TIM 750). Results. Total 36 PACD patients (72 eyes) with average age of 59.48 +/- 7.95 years were recruited, out of which 25 were females (69.44%) and 11 males (30.56%). The mean measurements of CCT, ACD, AOD500, and TISA on Casia and Visante machines were 522.5 +/- 34.75 mu m and 539.55 +/- 29.56 mu m (P = 0.00); ACD- 2.144 +/- 0.38 mu m and 2.133 +/- 0.39 mu m (P = 0.487); AOD500-0.27 +/- 0.16 mu m and 0.21 +/- 0.10 mu m (P = 0.04); and TISA500-0.100 +/- 0.07 mu m and 0.063 +/- 0.03 mu m (P = 0.00), respectively. A statistically significant difference was noted in CCT, N and T AOD, and TISA. A good corelation for ACD and CCT (ACD = 0.9816 and CCT = 0.772) only were noted between the two machines. The Bland-Altman plot analysis of different parameters between two machines has revealed good agreement of measurement of ACD and CCT but poor agreement for rest of the parameters. Conclusion: It is advisable not use the two machines interchangeably because of the wide limits of agreement and poor correlation of angle measurement values of Casia and Visante ASOCT.
引用
收藏
页码:500 / 504
页数:5
相关论文
共 50 条
  • [1] Qualitative evaluation of anterior segment in angle closure disease using anterior segment optical coherence tomography
    Moghimi, Sasan
    Chen, Rebecca
    Hamzeh, Nikoo
    Khatibi, Nassim
    Lin, Shan C.
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (04): : 170 - 175
  • [2] Quantitative evaluation of anterior chamber parameters using anterior segment optical coherence tomography in primary angle closure mechanisms
    Shabana, Noor
    Aquino, Maria C. D.
    See, Jovina
    Ce, Zheng
    Tan, Anna M.
    Nolan, Winifred P.
    Hitchings, Roger
    Young, Stephanie M.
    Loon, Seng Chee
    Sng, Chelvin C.
    Wong, Wanling
    Chew, Paul T. K.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (08) : 792 - 801
  • [3] Anterior Segment Optical Coherence Tomography Parameters in Subtypes of Primary Angle Closure
    Guzman, Celeste P.
    Gong, Tianxia
    Nongpiur, Monisha E.
    Perera, Shamira A.
    How, Alicia C.
    Lee, Hwee Kuan
    Cheng, Li
    He, Mingguang
    Baskaran, Mani
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) : 5281 - 5286
  • [4] Anterior Segment Optical Coherence Tomography: Is There a Clinical Role in the Management of Primary Angle Closure Disease?
    Nongpiur, Monisha E.
    Tun, Tin A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2020, 29 (01) : 60 - 66
  • [5] Anterior segment optical coherence tomography of acute primary angle closure
    Zhang, Hai Tao
    Xu, Liang
    Cao, Wei Fang
    Wang, Ya Xing
    Jonas, Jost B.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) : 825 - 831
  • [6] Anterior segment optical coherence tomography of acute primary angle closure
    Hai Tao Zhang
    Liang Xu
    Wei Fang Cao
    Ya Xing Wang
    Jost B. Jonas
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 825 - 831
  • [7] Evaluation of Anterior Segment Parameters in Pseudoexfoliation Disease Using Anterior Segment Optical Coherence Tomography
    Mohammadi, Massood
    Johari, Mohammadkarim
    Eslami, Yadollah
    Moghimi, Sasan
    Zarei, Reza
    Fakhraie, Ghasem
    Safizadeh, Mona
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 234 : 199 - 204
  • [8] Acute angle closure: qualitative and quantitative evaluation of the anterior segment using anterior segment optical coherence tomography
    Moghimi, Sasan
    Zandvakil, Narges
    Vahedian, Zakieh
    Mohammadi, Massood
    Fakhraie, Ghasem
    Coleman, Anne L.
    Lin, Shan C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07) : 615 - 622
  • [9] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [10] Role of anterior segment optical coherence tomography in angle-closure disease: a review
    Porporato, Natalia
    Baskaran, Mani
    Aung, Tin
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (02) : 147 - 157