Effect of electric vehicles on load frequency control in interconnected thermal and hydrothermal power systems utilising CF-FOIDF controller

被引:121
|
作者
Arya, Yogendra [1 ]
机构
[1] Maharaja Surajmal Inst Technol, Dept Elect & Elect Engn, New Delhi, India
关键词
electric vehicles; hydrothermal power systems; power system control; three-term control; robust control; frequency control; control system synthesis; load regulation; power generation control; cascade control; thermal power stations; fuzzy control; power system interconnection; optimal control; load frequency control; interconnected thermal power systems; CF-FOIDF controller; modern-complex-uncertain power systems; robust controllers; robust behaviour; changed operating condition; two-loops cascade fuzzy structured controllers; significant robust performance; filter controller; hydrothermal PSs; physical constraints; energy storage system; power plants; system frequency; load demands; control areas; robustness; control strategy; fuzzy-fractional order integral derivative with filter controller; EV fleets; AUTOMATIC-GENERATION CONTROL; FUZZY PID CONTROLLER; INTEGRAL DERIVATIVE CONTROLLER; CONTROL STRATEGY; ALGORITHM; SEARCH; DESIGN; AGC; OPTIMIZATION; FILTER;
D O I
10.1049/iet-gtd.2019.1217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Load frequency control in modern-complex-uncertain power systems (PSs) assumes significance due to their challenging nature of the operation and hence utilisation of robust controllers is indispensable. In the industry, conventional single-loop controllers may not offer robust behaviour under changed operating conditions. Alternatively, two-loop cascade fuzzy structured controllers can show significant robust performance in dynamic conditions and best suited in systems having non-linearities. Hence, a novel optimal cascade fuzzy-fractional order integral derivative with filter (CF-FOIDF) controller is utilised for 2-area thermal and hydrothermal PSs considering various physical constraints from a practical point of view. As physical constraints mandate an energy storage system, hence in this study, batteries of electric vehicles (EVs) are employed to assist power plants to swiftly arrest oscillations in the system frequency following load demands. A combined model of EV fleets is incorporated in the control areas of PSs. Numerous simulations are conducted to authenticate the robustness and excellence of EVs and the suggested control strategy over existing methods.
引用
收藏
页码:2666 / 2675
页数:10
相关论文
共 50 条
  • [1] Maiden application of cascade tilt-integral-tilt-derivative controller for performance analysis of load frequency control of interconnected multi-source power system
    Kumari, Sandhya
    Shankar, Gauri
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (23) : 5326 - 5338
  • [2] Water cycle algorithm-based load frequency controller for interconnected power systems comprising non-linearity
    El-Hameed, Mohammed A.
    El-Fergany, Attia A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (15) : 3950 - 3961
  • [3] Utilisation of plug-in electric vehicles for frequency regulation of multi-area thermal interconnected power systemInspec keywordsOther keywords
    Gaur, Pushpa
    Bhowmik, Debashish
    Soren, Nirmala
    IET ENERGY SYSTEMS INTEGRATION, 2019, 1 (02) : 88 - 96
  • [4] Maiden application of SSA-optimised CC-TID controller for load frequency control of power systems
    Guha, Dipayan
    Roy, Provas Kumar
    Banerjee, Subrata
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (07) : 1110 - 1120
  • [5] Load frequency control of interconnected hydrothermal power system based on FOPI? plus ?FOPD controller
    Cui, Mingyong
    Zhao, Yue
    Cao, Peng
    Tang, Yinggan
    Lu, Yao
    INTERNATIONAL JOURNAL OF DYNAMICS AND CONTROL, 2023, 12 (4) : 1073 - 1085
  • [6] A Robust Cascade Controller for Load Frequency Control of a Standalone Microgrid Incorporating Electric Vehicles
    Khokhar, Bhuvnesh
    Dahiya, Surender
    Singh Parmar, K. P.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2020, 48 (6-7) : 711 - 726
  • [7] Utilisation of ultra-capacitor in load frequency control under restructured STPP-thermal power systems using WOA optimised PIDN-FOPD controller
    Saha, Arindita
    Saikia, Lalit Chandra
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (13) : 3318 - 3331
  • [8] Inertia-adaptive model predictive control-based load frequency control for interconnected power systems with wind power
    Yang, Deyou
    Wang, Bo
    Cai, Guowei
    Ma, Jin
    Tian, Jie
    Chen, Zhe
    Wang, Lixin
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (22) : 5029 - 5036
  • [9] A novel adaptive load frequency control in single and interconnected power systems
    Mohamed, Tarek Hassan
    Alamin, Mohamed Abdelhamid Mohamed
    Hassan, Ammar M.
    AIN SHAMS ENGINEERING JOURNAL, 2021, 12 (02) : 1763 - 1773
  • [10] Optimum Modified Fractional Order Controller for Future Electric Vehicles and Renewable Energy-Based Interconnected Power Systems
    Ahmed, Emad M.
    Mohamed, Emad A.
    Elmelegi, Ahmed
    Aly, Mokhtar
    Elbaksawi, Osama
    IEEE ACCESS, 2021, 9 : 29993 - 30010