Rapid duplex immunoassay for wound biomarkers at the point-of-care

被引:40
|
作者
Worsley, G. J. [1 ]
Attree, S. L. [1 ]
Noble, J. E. [1 ]
Horgan, A. M. [1 ]
机构
[1] Natl Phys Lab, Biotechnol Grp, Qual Life Div, Teddington TW11 0LW, Middx, England
关键词
Diagnosis; Lateral flow; Multiplexing; Interleukin; 6; Tumour necrosis factor alpha; LATERAL FLOW ASSAY; LEG ULCERS; CYTOKINES; LABELS; SERS;
D O I
10.1016/j.bios.2012.02.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study we describe a novel method of sampling and quantifying wound biomarkers for clinical settings. We believe the chosen format will allow rapid assessments of wound healing and provide biomarker evidence-based decision points for treatment of the wound at the time of presentation. The wound monitoring principle uses a proprietary sample collection tool (a thermally reversible hydrogel) to sample and isolate biomarkers within a wound environment without further sample extraction/preparation steps. We show how gel samples can be analysed in a lateral flow assay format utilising fluorescent microspheres with optically discrete emission characteristics and demonstrate quantitative detection of two analytes (duplexing) achieved in a single test line. As a model assay, the chronic wound biomarkers interleukin 6 (IL6) and tumour necrosis factor alpha (TNF alpha) are used. Limits of detection of 48.5 pg/mL and 55.5 pg/mL respectively in hydrogel samples and 7.15 pg/mL and 10.7 pg/mL respectively in plasma are reported. We believe this is the first literature example of quantitative detection of multiple analytes within a single test line using spectral separation to distinguish the analytes. Crown Copyright (c) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 220
页数:6
相关论文
共 50 条
  • [1] Point-of-Care Fluorescence Immunoassay for Cardiac Panel Biomarkers
    Kim, Tae Kyum
    Oh, Sang Wook
    Hong, Soon Cheol
    Mok, Young Joon
    Choi, Eui Yul
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2014, 28 (06) : 419 - 427
  • [2] An enhanced centrifugation-assisted lateral flow immunoassay for the point-of-care detection of protein biomarkers
    Shen, Minjie
    Li, Nan
    Lu, Ying
    Cheng, Jing
    Xu, Youchun
    LAB ON A CHIP, 2020, 20 (15) : 2626 - 2634
  • [3] Evaluation of a point-of-care immunoassay test kit 'StrongStep' for cryptococcal antigen detection
    Mpoza, Edward
    Mukaremera, Liliane
    Kundura, Didas Atwebembere
    Akampurira, Andrew
    Luggya, Tonny
    Tadeo, Kiiza Kandole
    Pastick, Katelyn A.
    Bridge, Sarah C.
    Tugume, Lillian
    Kiggundu, Reuben
    Musubire, Abdu K.
    Williams, Darlisha A.
    Muzoora, Conrad
    Nalintya, Elizabeth
    Rajasingham, Radha
    Rhein, Joshua
    Boulware, David R.
    Meya, David B.
    Abassi, Mahsa
    PLOS ONE, 2018, 13 (01):
  • [4] Magnetic bead fluorescent immunoassay for the rapid detection of the novel inflammation marker YKL40 at the point-of-care
    Schmalenberg, Michael
    Beaudoin, Christopher
    Bulst, Ludwig
    Steubl, Dominik
    Luppa, Peter B.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2015, 427 : 36 - 41
  • [5] Point-of-care wound visioning technology: Reproducibility and accuracy of a wound measurement app
    Wang, Sheila C.
    Anderson, John A. E.
    Evans, Robyn
    Woo, Kevin
    Beland, Benjamin
    Sasseville, Denis
    Moreau, Linda
    PLOS ONE, 2017, 12 (08):
  • [6] Label-Free SERS and MD Analysis of Biomarkers for Rapid Point-of-Care Sensors Detecting Head and Neck Cancer and Infections
    Farnesi, Edoardo
    Rinaldi, Silvia
    Liu, Chen
    Ballmaier, Jonas
    Guntinas-Lichius, Orlando
    Schmitt, Michael
    Cialla-May, Dana
    Popp, Juergen
    SENSORS, 2023, 23 (21)
  • [7] Point-of-care rapid immunoassay performed on voided urine, refrigerated up to 24 hours, accurately detects bacteriuria
    Grant, David C.
    Keebaugh, Audrey E.
    Werre, Stephen
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2024, 262 (01): : 88 - 92
  • [8] Ultrasensitive and Robust Point-of-Care Immunoassay for the Detection of Plasmodium falciparum Malaria
    Salminen, Teppo
    Mehdi, Farha
    Rohila, Deepak
    Kumar, Manjit
    Talha, Sheikh M.
    Prakash, John Antony Jude
    Khanna, Navin
    Pettersson, Kim
    Batra, Gaurav
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 15766 - 15772
  • [9] Evaluation of the Multidimensional Enhanced Lateral Flow Immunoassay in Point-of-Care Nanosensors
    Liu, Sijie
    Liao, Yangjun
    Shu, Rui
    Sun, Jing
    Zhang, Daohong
    Zhang, Wentao
    Wang, Jianlong
    ACS NANO, 2024, 18 (40) : 27167 - 27205
  • [10] Point-of-care breath test for biomarkers of active pulmonary tuberculosis
    Phillips, Michael
    Basa-Dalay, Victoria
    Blais, Jaime
    Bothamley, Graham
    Chaturvedi, Anirudh
    Modi, Kinjal D.
    Pandya, Mauli
    Natividad, Maria Piedad R.
    Patel, Urvish
    Ramraje, Nagsen N.
    Schmitt, Peter
    Udwadia, Zarir F.
    TUBERCULOSIS, 2012, 92 (04) : 314 - 320