Energy-Dispersive X-ray Absorption Spectroscopy with an Inverse Compton Source

被引:13
|
作者
Huang, Juanjuan [1 ,2 ]
Guenther, Benedikt [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Cui, Yi-tao [3 ]
Gleich, Bernhard [2 ]
Dierolf, Martin [1 ,2 ]
Pfeiffer, Franz [1 ,2 ,4 ]
机构
[1] Tech Univ Munich, Dept Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch Bioengn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Japan Synchrotron Radiat Res Inst, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[4] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, D-81675 Munich, Germany
关键词
THOMSON-SCATTERING; EXAFS; TOMOGRAPHY; XAFS;
D O I
10.1038/s41598-020-65225-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Novel compact x-ray sources based on inverse Compton scattering can generate brilliant hard x-rays in a laboratory setting. Their collimated intense beams with tunable well-defined x-ray energies make them well suited for x-ray spectroscopy techniques, which are typically carried out at large facilities. Here, we demonstrate a first x-ray absorption spectroscopy proof-of-principle experiment using an inverse Compton x-ray source with a flux of >10(10) photons/s in <5% bandwidth. We measured x-ray absorption near edge structure and extended x-ray absorption fine structure at the silver K-edge (similar to 25.5 keV) for a series of silver samples. We propose an energy-dispersive geometry specifically adapted to the x-ray beam properties of inverse Compton x-ray sources together with a fast concentration correction method that corrects sample inhomogeneities very effectively. The combination of our setup with the inverse Compton source generates x-ray absorption spectra with high energy resolution in exposure times down to one minute. Our results unravel the great benefit of inverse Compton scattering sources for x-ray absorption techniques in a laboratory environment, especially in the hard x-ray regime, which allows to probe absorption edges of high Z materials.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Energy-dispersive X-ray-absorption edge spectrometry with spectrum filtration by X-ray mirrors
    A. G. Tur’yanskii
    S. S. Gizha
    V. M. Senkov
    S. K. Savel’ev
    Technical Physics Letters, 2014, 40 : 346 - 349
  • [32] CURVED CRYSTAL TRANSMISSION OPTICS FOR ENERGY-DISPERSIVE X-RAY-ABSORPTION SPECTROSCOPY
    HAGELSTEIN, M
    FERRERO, C
    HATJE, U
    RESSLER, T
    METZ, W
    JOURNAL OF SYNCHROTRON RADIATION, 1995, 2 : 174 - 180
  • [33] Energy-dispersive X-ray-absorption edge spectrometry with spectrum filtration by X-ray mirrors
    Tur'yanskii, A. G.
    Gizha, S. S.
    Senkov, V. M.
    Savel'ev, S. K.
    TECHNICAL PHYSICS LETTERS, 2014, 40 (04) : 346 - 349
  • [34] Automatic inverse pole figure measurement in steel by energy-dispersive X-ray diffraction
    Katayama, Michio
    Shimizu, Masato
    Maeda, Chizuko
    Kawasaki Steel Technical Report, 1988, (19): : 94 - 99
  • [35] High-focusing Bragg-crystal polychromator design for energy-dispersive X-ray absorption spectroscopy
    Europ. Synchrt. Radiation Facility, BP 220, F-38043 Grenoble CEDEX, France
    不详
    不详
    不详
    J. Synchrotron Radiat., 5 (1250-1257):
  • [36] High-focusing Bragg-crystal polychromator design for energy-dispersive X-ray absorption spectroscopy
    Pellicer-Porres, J
    San Miguel, A
    Fontaine, A
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1250 - 1257
  • [37] Synchrotron energy-dispersive X-ray diffraction tomography
    Hall, C
    Barnes, P
    Cockcroft, JK
    Colston, SL
    Hausermann, D
    Jacques, SDM
    Jupe, AC
    Kunz, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 140 (1-2): : 253 - 257
  • [38] OPTIMUM RESOLUTION IN X-RAY ENERGY-DISPERSIVE DIFFRACTOMETRY
    BURAS, B
    NIIMURA, N
    OLSEN, JS
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1978, 11 (APR) : 137 - 140
  • [39] Measuring performance of energy-dispersive X-ray systems
    Statham, PJ
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (06) : 605 - 615
  • [40] Gauge of an energy-dispersive X-ray fluorescence analyzer
    Bukin, KV
    Nakhabtsev, VS
    Romanova, NE
    Kirillov, VN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (03) : 393 - 397