Duration of Systole and Diastole for Hydrodynamic Testing of Prosthetic Heart Valves: Comparison Between ISO 5840 Standards and in vivo Studies

被引:8
作者
Bazan, Ovandir [1 ]
Ortiz, Jayme Pinto [1 ]
机构
[1] EPUSP, Dept Mech Engn, Av Prof Mello de Moraes 2231, BR-05508030 Sao Paulo, SP, Brazil
关键词
Ventricular Function; Left; Heart valve prosthesis; In Vitro Techniques; Heart Rate; IMAGE-RECONSTRUCTION; FLOW; PHASES; VITRO; CT;
D O I
10.5935/1678-9741.20160036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To complement the ISO 5840 standards concerning the duration of left ventricular systole and diastole as a function of changes in heart rates according to in vivo studies from the physiologic literature review. Methods: The systolic and diastolic durations from three in vivo studies were compared with the durations of systole proposed by the ISO 5840:2010 and ISO 5840-2:2015 for hydrodynamic performance assessment of prosthetic heart valves. Results: Based on the in vivo studies analyzed, the systolic durations proposed by the ISO 5840 standard seemed consistent for 45 and 120 beats per minute (bpm), and showed diverse results for the 70 bpm condition. Conclusion: Information on the realistic validation of the operation of left ventricular models for different heart rates were obtained.
引用
收藏
页码:171 / 173
页数:3
相关论文
共 14 条
  • [1] Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device
    Akagawa, Eiki
    Lee, Hwansung
    Tatsumi, Eisuke
    Homma, Akihiko
    Tsukiya, Tomonori
    Katagiri, Nobumasa
    Kakuta, Yukihide
    Nishinaka, Tomohiro
    Mizuno, Toshihide
    Ota, Kei
    Kansaku, Rei
    Taenaka, Yoshiyuki
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2007, 10 (02) : 85 - 91
  • [2] American National Standard, 2010, 58402005R2010 ANSIAA
  • [3] Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation
    Azadani, Ali N.
    Jaussaud, Nicolas
    Matthews, Peter B.
    Ge, Liang
    Guy, T. Sloane
    Chuter, Timothy A. M.
    Tseng, Elaine E.
    [J]. ANNALS OF THORACIC SURGERY, 2009, 88 (06) : 1857 - 1863
  • [4] Diastolic time - frequency relation in the stress echo lab: filling timing and flow at different heart rates
    Bombardini, Tonino
    Gemignani, Vincenzo
    Bianchini, Elisabetta
    Venneri, Lucia
    Petersen, Christina
    Pasanisi, Emilio
    Pratali, Lorenza
    Alonso-Rodriguez, David
    Pianelli, Mascia
    Faita, Francesco
    Giannoni, Massimo
    Arpesella, Giorgio
    Picano, Eugenio
    [J]. CARDIOVASCULAR ULTRASOUND, 2008, 6 (1)
  • [5] LINEAR RELATIONSHIP BETWEEN ELECTRICAL SYSTOLE, MECHANICAL SYSTOLE, AND HEART-RATE
    BOUDOULAS, H
    GELERIS, P
    LEWIS, RP
    RITTGERS, SE
    [J]. CHEST, 1981, 80 (05) : 613 - 618
  • [6] Duration of diastole and its phases as a function of heart rate during supine bicycle exercise
    Chung, CS
    Karamanoglu, M
    Kovács, SJ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (05): : H2003 - H2008
  • [7] In vitro evaluation of aortic valve prosthesis in a novel valved conduit with pseudosinuses of Valsalva
    De Paulis, R
    Schmitz, C
    Scaffa, R
    Nardi, P
    Chiariello, L
    Reul, H
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (04) : 1016 - 1021
  • [8] Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality
    Herzog, C
    Abolmaali, N
    Balzer, JO
    Baunach, S
    Ackermann, H
    Dogan, S
    Britten, MB
    Vogl, TJ
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2670 - 2678
  • [9] Coronary artery motion and cardiac phases: Dependency on heart rate - Implications for CT image reconstruction
    Husmann, Lars
    Leschka, Sebastian
    Desbiolles, Lotus
    Schepis, Tiziano
    Gaemperli, Oliver
    Seifert, Burkhardt
    Cattin, Philippe
    Frauenfelder, Thomas
    Flohr, Thomas G.
    Marincek, Borut
    Kaufmann, Philipp A.
    Alkadhi, Hatem
    [J]. RADIOLOGY, 2007, 245 (02) : 567 - 576
  • [10] International Standard, 2015, 584012015E ISO