ANN Based Data Integration for Multi-Path Ultrasonic Flowmeter

被引:33
|
作者
Zhao, Huichao [1 ]
Peng, Lihui [1 ]
Takahashi, Tsuyoshi
Hayashi, Takuya [2 ]
Shimizu, Kazuyoshi [2 ]
Yamamoto, Toshihiro [2 ]
机构
[1] Tsinghua Univ, Tsinghua Natl Lab Informat Sci & Technol, Dept Automat, Beijing 100084, Peoples R China
[2] Tokyo Keiso Ltd, Tokyo 1058558, Japan
关键词
Multipath ultrasonic flowmeter; ANN; CFD; flow profile; LASER-DOPPLER ANEMOMETRY; PIPE FLOWS; TOMOGRAPHY; PROFILES; METER;
D O I
10.1109/JSEN.2013.2282466
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an artificial neural network (ANN) based data integration method for a four-path ultrasonic flowmeter to improve its performance under complex flow profiles. Computational fluid dynamics (CFD) has been used to obtain the flow profiles inside a single elbow and an out-plane double-elbow pipeline, respectively, to extract the flow velocities on different individual sound paths and the corresponding mean flow velocities on the cross-sections located at 5 and 10 times pipe diameter downstream the elbow. The results from the CFD simulation for Reynolds number in the range from 3.25 x 10(3) to 3.25 x 10(5) were used to construct the data set. A three-layer ANN was designed, in which the flow velocities on individual sound paths and the cross-sectional mean flow velocity are taken as the input and output, respectively. Part of the data set is used to train the ANN. The other part of the data set is used to test the feasibility of the ANN. It was found that the error of the estimated cross-sectional mean flow velocity based on the ANN is within +/- 0.3% without the requirement of any flow conditioner for Reynolds number in the range from 3.25 x 10(3) to 3.25 x 10(5), which is significantly better than the results from the traditional weighted integration method. The proposed ANN based data integration method is of extending the limitation of straight pipe length for the installation of multi-path ultrasonic flowmeter and promoting its practical applications under complex flow profiles.
引用
收藏
页码:362 / 370
页数:9
相关论文
共 50 条
  • [1] Data Integration Method for Multipath Ultrasonic Flowmeter
    Peng, Lihui
    Zhang, Bowen
    Zhao, Huichao
    Stephane, Sonh Aubin
    Ishikawa, Hiroaki
    Shimizu, Kazuyoshi
    IEEE SENSORS JOURNAL, 2012, 12 (09) : 2866 - 2874
  • [2] Support Vector Regression-Based Data Integration Method for Multipath Ultrasonic Flowmeter
    Zhao, Huichao
    Peng, Lihui
    Takahashi, Tsuyoshi
    Hayashi, Takuya
    Shimizu, Kazuyoshi
    Yamamoto, Toshihiro
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (12) : 2717 - 2725
  • [3] Model simulation and experimental research of acoustic-plane installation angle of multi-path ultrasonic gas flowmeter
    Tang X.
    Zhang H.
    Xie X.
    Zhou H.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2017, 48 (07): : 1923 - 1929
  • [4] Integration method of multipath ultrasonic flowmeter based on velocity distribution
    Guo, Suna
    Xiang, Nuolin
    Li, Baonan
    Wang, Fan
    Zhao, Ning
    Zhang, Tao
    MEASUREMENT, 2023, 207
  • [5] An adaptive weighted integration method for multipath ultrasonic flowmeter
    Guo, Suna
    Han, Jiawen
    Li, Baonan
    Fang, Lide
    Zhang, Tao
    Wang, Fan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (11)
  • [6] CFD-Aided Investigation of Sound Path Position and Orientation for a Dual-Path Ultrasonic Flowmeter With Square Pipe
    Zhao, Huichao
    Peng, Lihui
    Takahashi, Tsuyoshi
    Hayashi, Takuya
    Shimizu, Kazuyoshi
    Yamamoto, Toshihiro
    IEEE SENSORS JOURNAL, 2015, 15 (01) : 128 - 137
  • [7] Accuracy of a multipath ultrasonic flowmeter with deep learning based on the velocity profile
    Xu, Zhijia
    Li, Minghai
    SENSOR REVIEW, 2024, 44 (01) : 13 - 21
  • [8] Performance of novel multipath ultrasonic phased array flowmeter using Gaussian quadrature integration
    Sakhavi, Noureddin
    Nouri, Nowrouz Mohammad
    APPLIED ACOUSTICS, 2022, 199
  • [9] Gas Flow-Rate Measurement Using A Transit-Time Multi-Path Ultrasonic Flow Meter Based on PSO-SVM
    Tang, Xiaoyu
    Yang, Qinmin
    Sun, Youxian
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1794 - 1799
  • [10] Optimization of ultrasound beam transmission path within measurement channel of ultrasonic flowmeter
    Ragauskas, A.
    Petkus, V.
    Borodicas, P.
    Bansevicius, R.
    Raisutis, R.
    Barauskas, R.
    Pamakstis, V.
    JOURNAL OF VIBROENGINEERING, 2010, 12 (04) : 582 - 588