Guided SH-SAW sensors for liquid-phase detection

被引:13
作者
Josse, F [1 ]
Bender, F [1 ]
Cernosek, RW [1 ]
Zinszer, K [1 ]
机构
[1] Marquette Univ, Microsensor Res Lab, Milwaukee, WI 53233 USA
来源
PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION | 2001年
关键词
D O I
10.1109/FREQ.2001.956273
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design and performance of guided shear horizontal surface acoustic wave (guided SH-SAW) devices on Li-TaO3 substrates are investigated for high sensitivity biochemical sensor in liquids. The device sensitivity to mass and viscoelastic loading is increased using a thin guiding layer of (cross-linked or cured) poly(methyl methacrylate) (PMMA) or cyanoethylcellulose (CEC) on the device surface. The devices have been tested in biosensing and chemical sensing experiments. Suitable design principles for these applications are discussed with regard to wave guidance, electrical passivation of the interdigital transducers (IDT) from the liquid environments, acoustic loss and sensor signal distortion. In biosensing experiments, using optimal PMMA thickness of approximately 2 gm, mass sensitivity greater than 1500 Hz/(ng/mm(2)) is demonstrated, resulting in a minimum detection limit less than 20 pg/mm(2). For chemical sensor experiments, it is found that optimal waveguide thickness must be modified to account for the chemically sensitive layer.
引用
收藏
页码:454 / 461
页数:8
相关论文
共 20 条
[1]   IMPROVED ACOUSTIC-PLATE-MODE BIOSENSOR [J].
ANDLE, JC ;
WEAVER, JT ;
MCALLISTER, DJ ;
JOSSE, F ;
VETELINO, JF .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) :437-442
[2]   AN ACOUSTIC PLATE MODE BIOSENSOR [J].
ANDLE, JC ;
VETELINO, JF ;
LADE, MW ;
MCALLISTER, DJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (02) :191-198
[3]  
ANDLE JC, 1991, P IEEE ULTR S, P285
[4]  
[Anonymous], 1990, ACOUSTIC FIELDS WAVE
[5]  
Baer R., 1992, P IEEE ULTR S, P293
[6]  
Ballantine D.S., 1997, ACOUSTIC WAVE SENSOR
[7]   Love-wave biosensors using cross-linked polymer waveguides on LiTaO3 substrates [J].
Bender, F ;
Cernosek, RW ;
Josse, F .
ELECTRONICS LETTERS, 2000, 36 (19) :1672-1673
[8]   ACOUSTIC PLATE MODE SENSOR FOR IMMUNOCHEMICAL REACTIONS [J].
DAHINT, R ;
GRUNZE, M ;
JOSSE, F ;
RENKEN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2888-2892
[9]   A multilayer structure for Love-mode acoustic sensors [J].
Du, J ;
Harding, GL .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 65 (2-3) :152-159
[10]   A LOVE PLATE BIOSENSOR UTILIZING A POLYMER LAYER [J].
GIZELI, E ;
GODDARD, NJ ;
LOWE, CR ;
STEVENSON, AC .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :131-137