The substitution of R134a with R744: An exergetic analysis based on experimental data

被引:39
作者
Aprea, Ciro [1 ]
Greco, Adriana [2 ]
Maiorino, Angelo [1 ]
机构
[1] Univ Salerno, Dipartimento Ingn Ind, I-84084 Salerno, Italy
[2] Univ Naples Federico II, DETEC, I-80125 Naples, Italy
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2013年 / 36卷 / 08期
关键词
CO2; R134a; Transcritical cycle; E.xergetic analysis; Exergy loss; INTERNAL HEAT-EXCHANGER; CARBON-DIOXIDE CYCLE; REFRIGERATION CYCLE; EXPANSION DEVICE; SYSTEM-DESIGN; PRESSURE;
D O I
10.1016/j.ijrefrig.2013.06.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with the problem of R314a substitution with a natural refrigerant fluid. A comparison is performed between R134a and R744 (CO2). R134a is a hydrofluorocarbon with a large direct warming impact (GWP), whereas the R744 contribution is negligible. A comparative exergetic analysis, carried out with experimental tests, has been presented. This paper compares a commercial R134a refrigeration plant and a prototype R744 system working in a trans-critical cycle. Based on the experimental data an exergetic analysis has been carried out on the overall plant and on each device. The overall exergetic performances of the classical vapour compression plant working with R134a are consistently better than that of R744 (from a minimum of 20 to a maximum of 44%). The performance of the individual components of the plant has been analyzed, in order to pinpoint those contributing most to the decrease in the exergetic performance of R744. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:2148 / 2159
页数:12
相关论文
共 47 条
[1]  
[Anonymous], 2000, 4 IIR GUST LOR C NAT
[2]  
[Anonymous], 1997, UN FRAM CONV CLIM CH
[3]   An experimental evaluation of the greenhouse effect in the substitution of R134a with CO2 [J].
Aprea, C. ;
Greco, A. ;
Maiorino, A. .
ENERGY, 2012, 45 (01) :753-761
[4]   Refrigeration plant exergetic analysis varying the compressor capacity [J].
Aprea, C ;
de Rossi, F ;
Greco, A ;
Renno, C .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (07) :653-669
[5]   An exergetic analysis of R22 substitution [J].
Aprea, C ;
Greco, A .
APPLIED THERMAL ENGINEERING, 2002, 22 (13) :1455-1469
[6]  
Aprea C., 1997, Measurement, V21, P65, DOI 10.1016/S0263-2241(97)00040-7
[7]   An experimental evaluation of the transcritical CO2 refrigerator performances using an internal heat exchanger [J].
Aprea, Ciro ;
Maiorino, Angelo .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (06) :1006-1011
[8]   Transcritical CO2 refrigerator and sub-critical R134a refrigerator: A comparison of the experimental results [J].
Aprea, Ciro ;
Maiorino, Angelo .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (12) :1040-1047
[9]   Heat rejection pressure optimization for a carbon dioxide split system: An experimental study [J].
Aprea, Ciro ;
Maiorino, Angelo .
APPLIED ENERGY, 2009, 86 (11) :2373-2380
[10]   Piston-cylinder work producing expansion device in a transcritical carbon dioxide cycle. Part II: theoretical model [J].
Baek, JS ;
Groll, EA ;
Lawless, PB .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02) :152-164