Transcatheter Aortic Valve Replacement Imaging Techniques for Aortic Root Sizing

被引:11
|
作者
Wichmann, Julian L. [1 ,3 ]
Varga-Szemes, Akos [1 ]
Suranyi, Pal [1 ]
Bayer, Richard R., II [1 ,2 ]
Litwin, Sheldon E. [1 ,2 ]
De Cecco, Carlo N. [1 ,5 ]
Mangold, Stefanie [1 ,4 ]
Muscogiuri, Giuseppe [1 ,6 ]
Fuller, Stephen R. [1 ]
Vogl, Thomas J. [3 ]
Steinberg, Daniel H. [2 ]
Schoepf, U. Joseph [1 ,2 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[3] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[4] Univ Tubingen Hosp, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[5] Univ Rome Sapienza Polo Pontino, Dept Radiol Sci Oncol & Pathol, Latina, Italy
[6] Univ Roma La Sapienza, Dept Med Surg Sci & Translat Med, I-00185 Rome, Italy
关键词
transcatheter aortic valve replacement; transcatheter aortic valve implantation; aortic stenosis; computed tomography; magnetic resonance imaging; CARDIOVASCULAR MAGNETIC-RESONANCE; MULTIDETECTOR COMPUTED-TOMOGRAPHY; DUAL-ENERGY CT; REDUCED IODINE LOAD; PULMONARY ANGIOGRAPHY; ANNULUS DIMENSIONS; PARAVALVULAR LEAK; IMPLANTATION; STENOSIS; ACCURACY;
D O I
10.1097/RTI.0000000000000167
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Transcatheter aortic valve replacement (TAVR) is an increasingly used alternative to surgical aortic valve replacement in patients with severe aortic stenosis and prohibitive perioperative risk. Several studies have shown an improved clinical outcome and lower rate of complications with TAVR in this patient population. Furthermore, TAVR has shown promising results in patients at elevated risk from surgical aortic valve replacement. Because of the endovascular nature of this technique, comprehensive preprocedural assessment of the aortic root and vascular access path is crucial. Although echocardiography is still commonly performed to assess the aortic root, cross-sectional imaging modalities are increasingly used given their superior results in the diagnostic accuracy of TAVR measurements. In particular, computed tomography (CT) is gaining an increasing role in pre-TAVR imaging because of fast 3-dimensional assessment of aortic root anatomy and improvements in clinical outcome after TAVR when CT is used for pre-TAVR planning. However, different algorithms exist for matching valve size to the aortic root and left ventricular outflow tract, and these measurements may substantially impact valve prosthesis selection and postinterventional complication rates. Cardiac magnetic resonance may play a role especially in post-TAVR assessment, as it provides both anatomic information and blood flow dynamics. This article reviews multimodality imaging approaches to pre-TAVR aortic root size assessment, provides an overview of the impact on post-TAVR complications and clinical outcome, and describes recent techniques to reduce contrast material volume in TAVR assessment with CT.
引用
收藏
页码:349 / 358
页数:10
相关论文
共 50 条
  • [31] Transcatheter Aortic Valve Replacement With Different Valve Types in Elliptic Aortic Annuli
    Maeno, Yoshio
    Abramowitz, Yigal
    Yoon, Sung-Han
    Jilaihawi, Hasan
    Raul, Sharma
    Israr, Sharjeel
    Miyasaka, Masaki
    Kawamori, Hiroyuki
    Kazuno, Yoshio
    Rami, Tanya
    Takahashi, Nobuyuki
    Mangat, Geeteshwar
    Kashif, Mohammad
    Chakravarty, Tarun
    Nakamura, Mamoo
    Cheng, Wen
    Makkar, Raj R.
    CIRCULATION JOURNAL, 2017, 81 (07) : 1036 - 1042
  • [32] Echocardiographic Imaging for Transcatheter Aortic Valve Replacement
    Hahn, Rebecca T.
    Nicoara, Alina
    Kapadia, Samir
    Svensson, Lars
    Martin, Randolph
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2018, 31 (04) : 405 - 433
  • [33] Transcatheter aortic valve replacement in bicuspid aortic valve disease
    Kochman, Janusz
    Rymuza, Bartosz
    Huczek, Zenon
    CURRENT OPINION IN CARDIOLOGY, 2015, 30 (06) : 594 - 602
  • [34] Role of Imaging in Transcatheter Aortic Valve Replacement
    Storz C.
    Geisler T.
    Notohamiprodjo M.
    Nikolaou K.
    Bamberg F.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (10)
  • [35] Bicuspid Aortic Valve Morphology and Outcomes After Transcatheter Aortic Valve Replacement
    Yoon, Sung-Han
    Kim, Won-Keun
    Dhoble, Abhijeet
    Pio, Stephan Milhorini
    Babaliaros, Vasilis
    Jilaihawi, Hasan
    Pilgrim, Thomas
    De Backer, Ole
    Bleiziffer, Sabine
    Vincent, Flavien
    Schmidit, Tobias
    Butter, Christian
    Kamioka, Norihiko
    Eschenbach, Lena
    Renker, Matthias
    Asami, Masahiko
    Lazkani, Mohamad
    Fujita, Buntaro
    Birs, Antoinette
    Barbanti, Marco
    Pershad, Ashish
    Landes, Uri
    Oldemeyer, Brad
    Kitamura, Mitusnobu
    Oakley, Luke
    Ochiai, Tomoki
    Chakravarty, Tarun
    Nakamura, Mamoo
    Ruile, Philip
    Deuschl, Florian
    Berman, Daniel
    Modine, Thomas
    Ensminger, Stephan
    Kornowski, Ran
    Lange, Rudiger
    McCabe, James M.
    Williams, Mathew R.
    Whisenant, Brian
    Delgado, Victoria
    Windecker, Stephan
    Van Belle, Eric
    Sondergaard, Lars
    Chevalier, Bernard
    Mack, Michael
    Bax, Jeroen J.
    Leon, Martin B.
    Makkar, Raj R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (09) : 1018 - 1030
  • [36] Use of imaging for procedural guidance during transcatheter aortic valve replacement
    Hahn, Rebecca T.
    CURRENT OPINION IN CARDIOLOGY, 2013, 28 (05) : 512 - 517
  • [37] Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Stenosis
    Vincent, Flavien
    Ternacle, Julien
    Denimal, Tom
    Shen, Mylene
    Redfors, Bjorn
    Delhaye, Cedric
    Simonato, Matheus
    Debry, Nicolas
    Verdier, Basile
    Shahim, Bahira
    Pamart, Thibault
    Spillemaeker, Hugues
    Schurtz, Guillaume
    Pontana, Francois
    Thourani, Vinod H.
    Pibarot, Philippe
    Van Belle, Eric
    CIRCULATION, 2021, 143 (10) : 1043 - 1061
  • [38] Transcatheter aortic valve replacement in patients with quadricuspid aortic valve in a single center
    Liu, Yang
    Zhai, Mengen
    Mao, Yu
    Xu, Chennian
    Ma, Yanyan
    Li, Lanlan
    Jin, Ping
    Yang, Jian
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [39] Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation
    Jilaihawi, Hasan
    Kashif, Mohammad
    Fontana, Gregory
    Furugen, Azusa
    Shiota, Takahiro
    Friede, Gerald
    Makhija, Rakhee
    Doctor, Niraj
    Leon, Martin B.
    Makkar, Raj R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) : 1275 - 1286
  • [40] Aortic Root Intussusception During Transcatheter Aortic Valve Replacement
    Jubran, Ayman
    Flugelman, Moshe Y.
    Khader, Nader
    Jaffe, Ronen
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (19) : E195 - E196