Transcatheter Aortic Valve Replacement Imaging Techniques for Aortic Root Sizing

被引:11
|
作者
Wichmann, Julian L. [1 ,3 ]
Varga-Szemes, Akos [1 ]
Suranyi, Pal [1 ]
Bayer, Richard R., II [1 ,2 ]
Litwin, Sheldon E. [1 ,2 ]
De Cecco, Carlo N. [1 ,5 ]
Mangold, Stefanie [1 ,4 ]
Muscogiuri, Giuseppe [1 ,6 ]
Fuller, Stephen R. [1 ]
Vogl, Thomas J. [3 ]
Steinberg, Daniel H. [2 ]
Schoepf, U. Joseph [1 ,2 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[3] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[4] Univ Tubingen Hosp, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[5] Univ Rome Sapienza Polo Pontino, Dept Radiol Sci Oncol & Pathol, Latina, Italy
[6] Univ Roma La Sapienza, Dept Med Surg Sci & Translat Med, I-00185 Rome, Italy
关键词
transcatheter aortic valve replacement; transcatheter aortic valve implantation; aortic stenosis; computed tomography; magnetic resonance imaging; CARDIOVASCULAR MAGNETIC-RESONANCE; MULTIDETECTOR COMPUTED-TOMOGRAPHY; DUAL-ENERGY CT; REDUCED IODINE LOAD; PULMONARY ANGIOGRAPHY; ANNULUS DIMENSIONS; PARAVALVULAR LEAK; IMPLANTATION; STENOSIS; ACCURACY;
D O I
10.1097/RTI.0000000000000167
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Transcatheter aortic valve replacement (TAVR) is an increasingly used alternative to surgical aortic valve replacement in patients with severe aortic stenosis and prohibitive perioperative risk. Several studies have shown an improved clinical outcome and lower rate of complications with TAVR in this patient population. Furthermore, TAVR has shown promising results in patients at elevated risk from surgical aortic valve replacement. Because of the endovascular nature of this technique, comprehensive preprocedural assessment of the aortic root and vascular access path is crucial. Although echocardiography is still commonly performed to assess the aortic root, cross-sectional imaging modalities are increasingly used given their superior results in the diagnostic accuracy of TAVR measurements. In particular, computed tomography (CT) is gaining an increasing role in pre-TAVR imaging because of fast 3-dimensional assessment of aortic root anatomy and improvements in clinical outcome after TAVR when CT is used for pre-TAVR planning. However, different algorithms exist for matching valve size to the aortic root and left ventricular outflow tract, and these measurements may substantially impact valve prosthesis selection and postinterventional complication rates. Cardiac magnetic resonance may play a role especially in post-TAVR assessment, as it provides both anatomic information and blood flow dynamics. This article reviews multimodality imaging approaches to pre-TAVR aortic root size assessment, provides an overview of the impact on post-TAVR complications and clinical outcome, and describes recent techniques to reduce contrast material volume in TAVR assessment with CT.
引用
收藏
页码:349 / 358
页数:10
相关论文
共 50 条
  • [21] Advances in transcatheter aortic valve replacement
    Ando, Tomo
    Briasoulis, Alexandros
    Panaich, Sidakpal
    JOURNAL OF GERIATRIC CARDIOLOGY, 2019, 16 (09) : 724 - 732
  • [22] Transcatheter Aortic Valve Replacement: A Review
    Braxton, John H.
    Rasmussen, Kelly S.
    Shah, Milind S.
    SURGICAL CLINICS OF NORTH AMERICA, 2017, 97 (04) : 899 - +
  • [23] Aortic Annular Sizing for Transcatheter Aortic Valve Replacement Using Cross-Sectional 3-Dimensional Transesophageal Echocardiography
    Jilaihawi, Hasan
    Doctor, Niraj
    Kashif, Mohammad
    Chakravarty, Tarun
    Rafique, Asim
    Makar, Moody
    Furugen, Azusa
    Nakamura, Mamoo
    Mirocha, James
    Gheorghiu, Mitch
    Stegic, Jasminka
    Okuyama, Kazuaki
    Sullivan, Daniel J.
    Siegel, Robert
    Min, James K.
    Gurudevan, Swaminatha V.
    Fontana, Gregory P.
    Cheng, Wen
    Friede, Gerald
    Shiota, Takahiro
    Makkar, Raj R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (09) : 908 - 916
  • [24] Role of Multimodality Imaging in Transcatheter Aortic Valve Replacement
    Ramineni, Rajesh
    Almomani, Ahmed
    Kumar, Arnav
    Ahmad, Masood
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (04): : 677 - 698
  • [25] Transapical transcatheter aortic valve replacement with a novel transcatheter aortic valve replacement system in high-risk patients with severe aortic valve diseases
    Zhu, Liming
    Guo, Yingqiang
    Wang, Wei
    Liu, Huan
    Yang, Ye
    Wei, Lai
    Wang, Chunsheng
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (02) : 588 - 597
  • [26] Balloon Versus Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement and the Impact of Left Ventricular Outflow Tract Calcification and Morphology on Sizing
    Condado, Jose F.
    Lerakis, Stamatios
    Stewart, James
    Jensen, Hanna
    Henry, Travis S.
    Ko, Sung Min
    Stillman, Arthur
    Rajaei, Mohammad H.
    Mavromatis, Kreton
    Devireddy, Chandan
    Sarin, Eric
    Leshnower, Brad
    Guyton, Robert
    Kaebnick, Brian
    Thourani, Vinod H.
    Block, Peter C.
    Babaliaros, Vasilis
    JOURNAL OF INVASIVE CARDIOLOGY, 2016, 28 (07) : 295 - 304
  • [27] Conformational Pulsatile Changes of the Aortic Annulus Impact on Prosthesis Sizing by Computed Tomography for Transcatheter Aortic Valve Replacement
    Blanke, Philipp
    Russe, Maximillian
    Leipsic, Jonathon
    Reinoehl, Jochen
    Ebersberger, Ullrich
    Suranyi, Pal
    Siepe, Matthias
    Pache, Gregor
    Langer, Mathias
    Schoepf, U. Joseph
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (09) : 984 - 994
  • [28] Potential impact of dynamic automated CT aortic annular measurements on outcomes for transcatheter aortic valve replacement sizing
    Subramanyam, Pritha
    Legasto, Alan C.
    Al'Aref, Subhi J.
    Wong, Shing Chiu
    Truong, Quynh A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (11) : 2291 - 2297
  • [29] Potential impact of dynamic automated CT aortic annular measurements on outcomes for transcatheter aortic valve replacement sizing
    Pritha Subramanyam
    Alan C. Legasto
    Subhi J. Al’Aref
    Shing Chiu Wong
    Quynh A. Truong
    The International Journal of Cardiovascular Imaging, 2020, 36 : 2291 - 2297
  • [30] Successful Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve
    Maeda, Koichi
    Kuratani, Toru
    Torikai, Kei
    Shimamura, Kazuo
    Ueno, Takayoshi
    Toda, Koichi
    Sawa, Yoshiki
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 : 705 - 708