Comparison of liquid chromatography-tandem mass spectrometry-based targeted proteomics and conventional analytical methods for the determination of P-glycoprotein in human breast cancer cells

被引:16
作者
Yang, Ting [1 ]
Xu, Feifei [1 ]
Xu, Jinhui [1 ]
Fang, Danjun [1 ]
Yu, Ying [1 ]
Chen, Yun [1 ]
机构
[1] Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2013年 / 936卷
基金
高等学校博士学科点专项科研基金;
关键词
P-glycoprotein; Liquid chromatography-tandem mass spectrometry; Targeted proteomics; Stable isotope labeling; Methods comparison; RESISTANCE-ASSOCIATED PROTEIN-2; MULTIDRUG-RESISTANCE; ABSOLUTE QUANTIFICATION; MEMBRANE-PROTEINS; TRANSPORTER; RESIDUES;
D O I
10.1016/j.jchromb.2013.07.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
P-glycoprotein (P-gp) is the most frequently proposed factor for multi-drug resistance. It is traditionally measured using antibody-based methods. While these techniques can provide relative quantification values for P-gp levels, the important information that is usually missing is its amount in the biological system. In this study, a novel and advanced liquid chromatography-tandem mass spectrometry (LC/MS/MS)-based targeted proteomics assay was developed and validated for the determination of P-gp in the breast cancer drug sensitive cell line MCF-7/WT and the drug resistant cell line MCF-7/ADR. Three tryptic peptides (434STTVQLMQR442, 674GSQAQDR680 and 368IIDNKPSIDSYSK380) can specifically represent P-gp. Among these peptides, 434STTVQLMQR442 was selected as the surrogate analyte for quantification, and a stable isotope-labeled synthetic peptide with the same sequence was used as an internal standard. The calibration range was validated from 10 to 1000 ng/mL. The intra- and inter-day precisions were within 5.9% and 3.7%, respectively. The accuracy for the quality control (QC) samples was within 8.0%. Using this assay, the amounts of P-gp were accurately quantified as 3.53 fg/cell (similar to 2.08 x 10(-2) amol/cell) in the MCF-7/WT cells and 34.5 fg/cell (similar to 2.02 x 10(-1) amol/cell) in the MCF-7/ADR cells. This outcome was then compared with those obtained by conventional analytical methods including confocal microscopy, western blotting and flow cytometry. The comparative results show that not only is the LC/MS/MS-based targeted proteomics assay able to monitor the protein levels in a more accurate manner, but the large discrepancy observed between the other methods was most likely due to the lack of specificity and the semi-quantitative nature of the conventional assays (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 50 条
[11]   Determination of Cefotiam in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry [J].
Du Ping ;
Li Peng-Fei ;
Liu Hong-Chuan ;
Yu Wei-Yue ;
Liu Li-Hong .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (06) :876-881
[12]   Determination of tandospirone in human plasma by a liquid chromatography-tandem mass spectrometry method [J].
Jin, Fengdan .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) :2881-2887
[13]   Determination of arotinoid acid in human plasma by liquid chromatography-tandem mass spectrometry [J].
Deng, Pan ;
Chen, Xiaoyan ;
Tang, Yunbiao ;
Wang, Yongqing ;
Zhang, Hongwen ;
Zhong, Dafang .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27) :2983-2988
[14]   Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry [J].
Bai, Nan ;
Cui, Xiang-Yong ;
Wang, Jin ;
Sun, Chun-Guang ;
Mei, He-Kun ;
Liang, Bei-Bei ;
Cai, Yun ;
Song, Xiu-Jie ;
Gu, Jing-Kai ;
Wang, Rui .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (02) :626-630
[15]   Abundance of P-glycoprotein and Breast Cancer Resistance Protein Measured by Targeted Proteomics in Human Epileptogenic Brain Tissue [J].
Brukner, Aniv Mann ;
Billington, Sarah ;
Benifla, Mony ;
Tot Bui Nguyen ;
Han, Hadas ;
Bennett, Odeya ;
Gilboa, Tal ;
Blatch, Dana ;
Fellig, Yakov ;
Volkov, Olga ;
Unadkat, Jashvant D. ;
Ekstein, Dana ;
Eyal, Sara .
MOLECULAR PHARMACEUTICS, 2021, 18 (06) :2263-2273
[16]   Comparison of gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry methods to quantify α-tocopherol and α-tocopherolquinone levels in human plasma [J].
Mottier, P ;
Gremaud, E ;
Guy, PA ;
Turesky, RJ .
ANALYTICAL BIOCHEMISTRY, 2002, 301 (01) :128-135
[17]   Validation of Liquid Chromatography-Tandem Mass Spectrometry-Based 5-Plex Assay for Mucopolysaccharidoses [J].
Oguni, Tsubasa ;
Tomatsu, Shunji ;
Tanaka, Misa ;
Orii, Kenji ;
Fukao, Toshiyuki ;
Watanabe, Jun ;
Fukuda, Seiji ;
Notsu, Yoshitomo ;
Dung Chi Vu ;
Thi Bich Ngoc Can ;
Nagai, Atsushi ;
Yamaguchi, Seiji ;
Taketani, Takeshi ;
Gelb, Michael H. ;
Kobayashi, Hironori .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (06)
[18]   Determination of the active metabolite of prulifloxacin in human plasma by liquid chromatography-tandem mass spectrometry [J].
Guo, LX ;
Qi, ML ;
Jin, X ;
Wang, P ;
Zhao, HQ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (02) :280-285
[19]   Simultaneous determination of phytoestrogens and key metabolites in breast cancer patients' urine by liquid chromatography-tandem mass spectrometry [J].
Yu, Jing ;
Wu, Qian ;
Qiao, Shanlei ;
Yu, Zeping ;
Jin, Nianzu ;
Yu, Boyang .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) :939-946
[20]   Determination of p-aminohippuric acid in rat plasma by liquid chromatography-tandem mass spectrometry [J].
Fan, Hsien-Yuan ;
Lin, Chang-Ching ;
Pao, Li-Heng .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19) :1643-1646