Comparison of liquid chromatography-tandem mass spectrometry-based targeted proteomics and conventional analytical methods for the determination of P-glycoprotein in human breast cancer cells

被引:16
|
作者
Yang, Ting [1 ]
Xu, Feifei [1 ]
Xu, Jinhui [1 ]
Fang, Danjun [1 ]
Yu, Ying [1 ]
Chen, Yun [1 ]
机构
[1] Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2013年 / 936卷
基金
高等学校博士学科点专项科研基金;
关键词
P-glycoprotein; Liquid chromatography-tandem mass spectrometry; Targeted proteomics; Stable isotope labeling; Methods comparison; RESISTANCE-ASSOCIATED PROTEIN-2; MULTIDRUG-RESISTANCE; ABSOLUTE QUANTIFICATION; MEMBRANE-PROTEINS; TRANSPORTER; RESIDUES;
D O I
10.1016/j.jchromb.2013.07.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
P-glycoprotein (P-gp) is the most frequently proposed factor for multi-drug resistance. It is traditionally measured using antibody-based methods. While these techniques can provide relative quantification values for P-gp levels, the important information that is usually missing is its amount in the biological system. In this study, a novel and advanced liquid chromatography-tandem mass spectrometry (LC/MS/MS)-based targeted proteomics assay was developed and validated for the determination of P-gp in the breast cancer drug sensitive cell line MCF-7/WT and the drug resistant cell line MCF-7/ADR. Three tryptic peptides (434STTVQLMQR442, 674GSQAQDR680 and 368IIDNKPSIDSYSK380) can specifically represent P-gp. Among these peptides, 434STTVQLMQR442 was selected as the surrogate analyte for quantification, and a stable isotope-labeled synthetic peptide with the same sequence was used as an internal standard. The calibration range was validated from 10 to 1000 ng/mL. The intra- and inter-day precisions were within 5.9% and 3.7%, respectively. The accuracy for the quality control (QC) samples was within 8.0%. Using this assay, the amounts of P-gp were accurately quantified as 3.53 fg/cell (similar to 2.08 x 10(-2) amol/cell) in the MCF-7/WT cells and 34.5 fg/cell (similar to 2.02 x 10(-1) amol/cell) in the MCF-7/ADR cells. This outcome was then compared with those obtained by conventional analytical methods including confocal microscopy, western blotting and flow cytometry. The comparative results show that not only is the LC/MS/MS-based targeted proteomics assay able to monitor the protein levels in a more accurate manner, but the large discrepancy observed between the other methods was most likely due to the lack of specificity and the semi-quantitative nature of the conventional assays (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 50 条
  • [1] A liquid chromatography-tandem mass spectrometry-based targeted proteomics assay for monitoring P-glycoprotein levels in human breast tissue
    Yang, Ting
    Chen, Fei
    Xu, Feifei
    Wang, Fengliang
    Xu, Qingqing
    Chen, Yun
    CLINICA CHIMICA ACTA, 2014, 436 : 283 - 289
  • [2] An investigation of heat shock protein 27 and P-glycoprotein mediated multi-drug resistance in breast cancer using liquid chromatography-tandem mass spectrometry-based targeted proteomics
    Xu, Feifei
    Yang, Ting
    Fang, Danjun
    Xu, Qingqing
    Chen, Yun
    JOURNAL OF PROTEOMICS, 2014, 108 : 188 - 197
  • [3] A liquid chromatography-tandem mass spectrometry-based targeted proteomics approach for the assessment of transferrin receptor levels in breast cancer
    Yang, Ting
    Xu, Feifei
    Zhao, Yi
    Wang, Shui
    Yang, Mi
    Chen, Yun
    PROTEOMICS CLINICAL APPLICATIONS, 2014, 8 (9-10) : 773 - 782
  • [4] Quantification of human serum transferrin using liquid chromatography-tandem mass spectrometry based targeted proteomics
    Yu, Ying
    Xu, Jinhui
    Liu, Yuan
    Chen, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 902 : 10 - 15
  • [5] Liquid chromatography/tandem mass spectrometry based targeted proteomics quantification of P-glycoprotein in various biological samples
    Zhang, Yiqun
    Li, Na
    Brown, Paul W.
    Ozer, Josef S.
    Lai, Yurong
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (12) : 1715 - 1724
  • [6] Simultaneous Quantification of Protein Phosphorylation Sites using Liquid Chromatography-Tandem Mass Spectrometry-Based Targeted Proteomics: A Linear Algebra Approach for Isobaric Phosphopeptides
    Xu, Feifei
    Yang, Ting
    Sheng, Yuan
    Zhong, Ting
    Yang, Mi
    Chen, Yun
    JOURNAL OF PROTEOME RESEARCH, 2014, 13 (12) : 5452 - 5460
  • [7] Determination of tropisetron in human plasma by liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Zhong, Dafang
    Chen, Xiaoyan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) : 848 - 852
  • [8] Determination of captopril in human plasma by liquid chromatography-tandem mass spectrometry
    Zhao Limei
    Hu Ligang
    Jiang Yao
    Wang Jiang
    Wang Ling
    Gu Jingkai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (11) : 1599 - 1602
  • [9] Membrane proteomics by high performance liquid chromatography-tandem mass spectrometry: Analytical approaches and challenges
    Vuckovic, Dajana
    Dagley, Laura F.
    Purcell, Anthony W.
    Emili, Andrew
    PROTEOMICS, 2013, 13 (3-4) : 404 - 423
  • [10] Comparison of commercial nanoliquid chromatography columns for fast, targeted mass spectrometry-based proteomics
    Vehus, Tore
    Seterdal, Kristina Erikstad
    Krauss, Stefan
    Lundanes, Elsa
    Wilson, Steven R.