Assessment of Bacterial Aerosol in a Preschool, Primary School and High School in Poland

被引:50
作者
Bragoszewska, Ewa [1 ]
Mainka, Anna [1 ]
Pastuszka, Jozef S. [1 ]
Lizonczyk, Katarzyna [2 ]
Desta, Yitages Getachew [1 ,3 ]
机构
[1] Silesian Tech Univ, Dept Air Protect, 22B Konarskiego St, PL-44100 Gliwice, Poland
[2] Adam Mickiewicz High Sch, Mickiewicza St 11, PL-40092 Katowice, Poland
[3] Jimma Univ, Dept Environm Hlth Sci & Technol, Jimma 251, Ethiopia
关键词
bioaerosol; size distribution; monitoring; indoor air quality; preschool; primary school; high school; INDOOR AIR-QUALITY; IN-HOUSE DUST; BIOAEROSOL CONCENTRATIONS; FUNGAL AEROSOLS; UPPER SILESIA; URBAN; ENVIRONMENTS; BUILDINGS; CHILDREN; UNIVERSITY;
D O I
10.3390/atmos9030087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The issue of healthy educational buildings is a global concern because children are particularly at risk of lung damage and infection caused by poor indoor air quality (IAQ). This article presents the results of a preliminary study of the concentration and size distribution of bacterial aerosol in three educational buildings: a preschool, primary school, and high school. Sampling was undertaken in the classrooms with an Andersen six-stage impactor (with aerodynamic cut-off diameters of 7.0, 4.7, 3.3, 2.1, 1.1 and 0.65 mu m) during spring 2016 and 2017, as well as the outside of the buildings. After incubation, bioaerosol particles captured on nutrient media on Petri dishes were quantitatively evaluated and qualitatively identified. The highest average concentration of bacterial aerosol was inside the primary school building (2205 CFU/m(3)), whereas the lowest average concentration of indoor culturable bacteria was observed in the high school building (391 CFU/m(3)). Using the obtained data, the exposure dose (ED) of the bacterial aerosol was estimated for children attending each educational level. The most frequently occurring species in the sampled bacterial aerosol were Gram-positive cocci in the indoor environment and Gram-positive rod-forming endospores in the outdoor environment.
引用
收藏
页数:15
相关论文
共 71 条
[1]   Sinus Microbiome Diversity Depletion and Corynebacterium tuberculostearicum Enrichment Mediates Rhinosinusitis [J].
Abreu, Nicole A. ;
Nagalingam, Nabeetha A. ;
Song, Yuanlin ;
Roediger, Frederick C. ;
Pletcher, Steven D. ;
Goldberg, Andrew N. ;
Lynch, Susan V. .
SCIENCE TRANSLATIONAL MEDICINE, 2012, 4 (151)
[2]   Chamber Bioaerosol Study: Outdoor Air and Human Occupants as Sources of Indoor Airborne Microbes [J].
Adams, Rachel I. ;
Bhangar, Seema ;
Pasut, Wilmer ;
Arens, Edward A. ;
Taylor, John W. ;
Lindow, Steven E. ;
Nazaroff, William W. ;
Bruns, Thomas D. .
PLOS ONE, 2015, 10 (05)
[3]   Children exposure to atmospheric particles in indoor of Lisbon primary schools [J].
Almeida, Susana Marta ;
Canha, Nuno ;
Silva, Ana ;
Freitas, Maria do Carmo ;
Pegas, Priscilla ;
Alves, Celia ;
Evtyugina, Margarita ;
Pio, Casimiro Adriao .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (40) :7594-7599
[4]  
[Anonymous], 2005, 12322 PNEN
[5]  
[Anonymous], E3S WEB C
[6]  
[Anonymous], BEZPIECZENSTWO PRACY
[7]  
[Anonymous], 2016, AIR WATER BOURNE DIS, DOI DOI 10.4172/2167-7719.1000131
[8]  
[Anonymous], BIOAEROSOLS WORKPLAC
[9]  
[Anonymous], P 2 INT C ENV SCI TE
[10]  
[Anonymous], ED 2015 2016 SCH YEA