Transcranial doppler: Technique and common findings (Part 1)

被引:61
作者
Bathala, Lokesh [1 ]
Mehndiratta, Man Mohan [2 ]
Sharma, Vijay K. [3 ]
机构
[1] Narayana Med Coll & Hosp, Dept Neurol, Nellore 524001, Andhra Pradesh, India
[2] GB Pant Hosp, Dept Neurol, Delhi, India
[3] Natl Univ Singapore Hosp, Div Neurol, Singapore 117548, Singapore
关键词
Ischemic stroke; intracranial stenosis; transcranial doppler; ULTRASOUND; STROKE; FLOW; THROMBOLYSIS; VELOCITY;
D O I
10.4103/0972-2327.112460
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Transcranial Doppler (TCD) can be aptly called as the doctors stethoscope of the brain. Since its introduction in 1982, by Rune Aaslid, TCD has evolved as a diagnostic, monitoring, and therapeutic tool. During evaluation of patients with acute ischemic stroke, TCD combined with cervical duplex ultrasonography provides physiological information on the cerebral hemodynamics, which is often complementary to structural imaging. Currently, TCD is the only diagnostic tool that can provide real time information about cerebral hemodynamics and can detect embolization to the cerebral vessels. TCD is a noninvasive, cost-effective, and bedside tool for obtaining information regarding the collateral flow across various branches of the circle of Willis in patients with cerebrovascular disorders. Advanced applications of TCD help in the detection of right-to-left shunts, vasomotor reactivity, diagnosis, and monitoring of vasospasm in subarachnoid hemorrhage and as a supplementary test for confirmation of brain death. This article describes the basic ultrasound physics pertaining to TCD insonation methods, for detecting the flow in intracranial vessels in addition to the normal and abnormal spectral flow patterns.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 21 条
  • [1] NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES
    AASLID, R
    MARKWALDER, TM
    NORNES, H
    [J]. JOURNAL OF NEUROSURGERY, 1982, 57 (06) : 769 - 774
  • [2] THE USE OF TRANSCRANIAL ULTRASONOGRAPHY TO PREDICT STROKE IN SICKLE-CELL DISEASE
    ADAMS, R
    MCKIE, V
    NICHOLS, F
    CARL, E
    ZHANG, DL
    MCKIE, K
    FIGUEROA, R
    LITAKER, M
    THOMPSON, W
    HESS, D
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (09) : 605 - 610
  • [3] Alexandrov AA, 2011, CEREBROVASCULAR ULTR, p[13, 81], DOI [10.1002/9781444327373.ch2, DOI 10.1002/9781444327373.CH2]
  • [4] A pilot randomized clinical safety study of sonothrombolysis augmentation with ultrasound-activated perflutren-lipid microspheres for acute ischemic stroke
    Alexandrov, Andrei V.
    Mikulik, Robert
    Ribo, Marc
    Sharma, Vijay K.
    Lao, Annabelle Y.
    Tsivgoulis, Georgios
    Sugg, Rebecca M.
    Barreto, Andrew
    Sierzenski, Paul
    Malkoff, Marc D.
    Grotta, James C.
    [J]. STROKE, 2008, 39 (05) : 1464 - 1469
  • [5] Practice standards for transcranial Doppler ultrasound: Part I - Test performance
    Alexandrov, Andrei V.
    Sloan, Michael A.
    Wong, Lawrence K. S.
    Douville, Colleen
    Razumovsky, Alexander Y.
    Koroshetz, Walter J.
    Kaps, Manfred
    Tegeler, Charles H.
    [J]. JOURNAL OF NEUROIMAGING, 2007, 17 (01) : 11 - 18
  • [6] Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke
    Alexandrov, AV
    Molina, CA
    Grotta, JC
    Garami, Z
    Ford, SR
    Alvarez-Sabin, J
    Montaner, J
    Saqqur, M
    Demchuk, AM
    Moye, LA
    Hill, MD
    Wojner, AW
    Al-Senani, F
    Burgin, S
    Calleja, S
    Campbell, M
    Chen, CI
    Chernyshev, O
    Choi, J
    El-Mitwalli, A
    Felberg, R
    Ford, S
    Garami, Z
    Irr, W
    Grotta, J
    Hall, C
    Iguchi, Y
    Ireland, J
    Labiche, L
    Malkoff, M
    Morgenstern, L
    Noser, E
    Okon, N
    Piriyawat, P
    Robinson, D
    Shaltoni, H
    Shaw, S
    Uchino, K
    Yatsu, F
    Alvarez-Sabín, J
    Arenillas, JF
    Huertas, R
    Molina, C
    Montaner, J
    Ribó, M
    Rubiera, M
    Santamarina, E
    Saqqur, M
    Alchtar, N
    O'Rourke, F
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (21) : 2170 - 2178
  • [7] Insonation method and diagnostic flow signatures for transcranial power motion (M-mode) Doppler
    Alexandrov, AV
    Demchuk, AM
    Burgin, WS
    [J]. JOURNAL OF NEUROIMAGING, 2002, 12 (03) : 236 - 244
  • [8] Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts
    Belvís, R
    Leta, RG
    Martí-Fàbregas, J
    Cocho, D
    Carreras, F
    Pons-Lladó, G
    Martí-Vilalta, JL
    [J]. JOURNAL OF NEUROIMAGING, 2006, 16 (02) : 133 - 138
  • [9] Yield and accuracy of urgent combined carotid/transcranial ultrasound testing in acute cerebral ischemia
    Chernyshev, OY
    Garami, Z
    Calleja, S
    Song, J
    Campbell, MS
    Noser, EA
    Shaltoni, H
    Chen, CI
    Iguchi, Y
    Grotta, JC
    Alexandrov, AV
    [J]. STROKE, 2005, 36 (01) : 32 - 37
  • [10] Edelman SK, 2007, DOPPLER UNDERSTANDIN, P293