Hyperpolarized 129Xe MRI of the human lung

被引:292
作者
Mugler, John P. [1 ]
Altes, Talissa A. [1 ]
机构
[1] Univ Virginia, Sch Med, Ctr In Vivo Hyperpolarized Gas MR Imaging, Dept Radiol & Med Imaging, Charlottesville, VA 22908 USA
基金
美国国家卫生研究院;
关键词
hyperpolarized gas; lung imaging; pulmonary disease; xenon-129; helium-3; LASER-POLARIZED XE-129; HE-3 DIFFUSION MRI; TO-NOISE RATIO; NUCLEAR-MAGNETIC-RESONANCE; OXYGEN PARTIAL-PRESSURE; SINGLE BREATH-HOLD; IN-VIVO; EMPHYSEMATOUS CHANGES; GAS-EXCHANGE; AIR SPACES;
D O I
10.1002/jmri.23844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
By permitting direct visualization of the airspaces of the lung, magnetic resonance imaging (MRI) using hyperpolarized gases provides unique strategies for evaluating pulmonary structure and function. Although the vast majority of research in humans has been performed using hyperpolarized 3He, recent contraction in the supply of 3He and consequent increases in price have turned attention to the alternative agent, hyperpolarized 129Xe. Compared to 3He, 129Xe yields reduced signal due to its smaller magnetic moment. Nonetheless, taking advantage of advances in gas-polarization technology, recent studies in humans using techniques for measuring ventilation, diffusion, and partial pressure of oxygen have demonstrated results for hyperpolarized 129Xe comparable to those previously demonstrated using hyperpolarized 3He. In addition, xenon has the advantage of readily dissolving in lung tissue and blood following inhalation, which makes hyperpolarized 129Xe particularly attractive for exploring certain characteristics of lung function, such as gas exchange and uptake, which cannot be accessed using 3He. Preliminary results from methods for imaging 129Xe dissolved in the human lung suggest that these approaches will provide new opportunities for quantifying relationships among gas delivery, exchange, and transport, and thus show substantial potential to broaden our understanding of lung disease. Finally, recent changes in the commercial landscape of the hyperpolarized-gas field now make it possible for this innovative technology to move beyond the research laboratory. J. Magn. Reson. Imaging 2013;37:313331. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:313 / 331
页数:19
相关论文
共 107 条
[1]   Measurement of xenon diffusing capacity in the rat lung by hyperpolarized 129Xe MRI and dynamic spectroscopy in a single breath-hold [J].
Abdeen, Nishard ;
Cross, Albert ;
Cron, Gregory ;
White, Steven ;
Rand, Thomas ;
Miller, David ;
Santyr, Giles .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) :255-264
[2]   SOLUBILITY PROPERTIES IN POLYMERS AND BIOLOGICAL MEDIA .2. THE CORRELATION AND PREDICTION OF THE SOLUBILITIES OF NONELECTROLYTES IN BIOLOGICAL TISSUES AND FLUIDS [J].
ABRAHAM, MH ;
KAMLET, MJ ;
TAFT, RW ;
DOHERTY, RM ;
WEATHERSBY, PK .
JOURNAL OF MEDICINAL CHEMISTRY, 1985, 28 (07) :865-870
[3]  
ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
[4]   Hyperpolarized 3He MR lung ventilation imaging in asthmatics:: Preliminary findings [J].
Altes, TA ;
Powers, PL ;
Knight-Scott, J ;
Rakes, G ;
Platts-Mills, TAE ;
de Lange, EE ;
Alford, BA ;
Mugler, JP ;
Brookeman, JR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) :378-384
[5]  
Altes TA, 2012, P 20 ANN M ISMRM MEL, P1354
[6]  
Altes TA., 2010, P 18 ANN M ISMRM STO, P2529
[7]   Assessment of lung development using hyperpolarized helium-3 diffusion MR imaging [J].
Altes, Talissa A. ;
Mata, Jaime ;
de lange, Eduard E. ;
Brookeman, James R. ;
Mugler, John P., III .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) :1277-1283
[8]   In vivo He-3 MR images of guinea pig lungs [J].
Black, RD ;
Middleton, HL ;
Cates, GD ;
Cofer, GP ;
Driehuys, B ;
Happer, W ;
Hedlund, LW ;
Johnson, GA ;
Shattuck, MD ;
Swartz, JC .
RADIOLOGY, 1996, 199 (03) :867-870
[9]   Simultaneous T-2* and diffusion measurements with He-3 [J].
Bock, M .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :890-895
[10]   NUCLEAR POLARIZATION IN HE-3 GAS INDUCED BY OPTICAL PUMPING AND DIPOLAR EXCHANGE [J].
BOUCHIAT, MA ;
CARVER, TR ;
VARNUM, CM .
PHYSICAL REVIEW LETTERS, 1960, 5 (08) :373-375