Ambient temperature detection of PCR amplicons with a novel sequence-specific nucleic acid lateral flow biosensor

被引:47
作者
Ang, Geik Yong [1 ]
Yu, Choo Yee [1 ]
Yean, Chan Yean [1 ]
机构
[1] Univ Sains Malaysia, Sch Med Sci, Dept Med Microbiol & Parasitol, Kubang Kerian 16150, Kelantan, Malaysia
关键词
DNA biosensor; LATE-PCR; Dipstick; Cholera toxin; Sequence-specific detection; Vibrio cholerae; THE-EXPONENTIAL (LATE)-PCR; VISUAL DETECTION; DNA BIOSENSOR; DIPSTICK-TYPE; AMPLIFICATION; DIAGNOSIS; DESIGN; O1;
D O I
10.1016/j.bios.2012.05.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the field of diagnostics, molecular amplification targeting unique genetic signature sequences has been widely used for rapid identification of infectious agents, which significantly aids physicians in determining the choice of treatment as well as providing important epidemiological data for surveillance and disease control assessment. We report the development of a rapid nucleic acid lateral flow biosensor (NALFB) in a dry-reagent strip format for the sequence-specific detection of single-stranded polymerase chain reaction (PCR) amplicons at ambient temperature (22-25 degrees C). The NALFB was developed in combination with a linear-after-the-exponential PCR assay and the applicability of this biosensor was demonstrated through detection of the cholera toxin gene from diarrheal-causing toxigenic Vibrio cholerae. Amplification using the advanced asymmetric PCR boosts the production of fluorescein-labeled single-stranded amplicons, allowing capture probes immobilized on the NALFB to hybridize specifically with complementary targets in situ on the strip. Subsequent visual formation of red lines is achieved through the binding of conjugated gold nanoparticles to the fluorescein label of the captured amplicons. The visual detection limit observed with synthetic target DNA was 0.3 ng and 1 pg with pure genomic DNA. Evaluation of the NALFB with 164 strains of V. cholerae and non-V. cholerae bacteria recorded 100% for both sensitivity and specificity. The whole procedure of the low-cost NALFB, which is performed at ambient temperature, eliminates the need for preheated buffers or additional equipment, greatly simplifying the protocol for sequence-specific PCR amplicon analysis. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 30 条
[1]   Detection of schistosomes polymerase chain reaction amplified DNA by oligochromatographic dipstick [J].
Akinwale, O. P. ;
Laurent, T. ;
Mertens, P. ;
Leclipteux, T. ;
Rollinson, D. ;
Kane, R. ;
Emery, A. ;
Ajayi, M. B. ;
Akande, D. O. ;
Fesobi, T. W. .
MOLECULAR AND BIOCHEMICAL PARASITOLOGY, 2008, 160 (02) :167-170
[2]   Molecular Evidence of Cholera Outbreak Caused by a Toxigenic Vibrio cholerae O1 El Tor Variant Strain in Kelantan, Malaysia [J].
Ang, Geik Yong ;
Yu, Choo Yee ;
Balqis, Kamarudin ;
Elina, Husni Tan ;
Azura, Hussin ;
Hani, Mat Hussin ;
Yean, Chan Yean .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (11) :3963-3969
[3]   Immunochromatographic strip test for detection of genus Cronobacter [J].
Blazkova, Martina ;
Javurkova, Barbora ;
Fukal, Ladislav ;
Rauch, Pavel .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (06) :2828-2834
[4]   Development of a nucleic acid lateral flow immunoassay for simultaneous detection of Listeria spp. and Listeria monocytogenes in food [J].
Blazkova, Martina ;
Koets, Marjo ;
Rauch, Pavel ;
van Amerongen, Aart .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2009, 229 (06) :867-874
[5]   A rapid DNA biosensor for the molecular diagnosis of infectious disease [J].
Chua, AngLim ;
Yean, Chan Yean ;
Ravichandran, Manickam ;
Lim, BoonHuat ;
Lalitha, Pattabhiraman .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (09) :3825-3831
[6]  
Chun P, 2009, LATERAL FLOW IMMUNOASSAY, P75, DOI 10.1007/978-1-59745-240-3_5
[7]   A Simplified and Standardized Polymerase Chain Reaction Format for the Diagnosis of Leishmaniasis [J].
Deborggraeve, Stijn ;
Laurent, Thierry ;
Espinosa, Diego ;
Van der Auwera, Gert ;
Mbuchi, Margaret ;
Wasunna, Monique ;
El-Safi, Sayda ;
Al-Basheer, Ahmed Almustafa ;
Arevalo, Jorge ;
Miranda-Verastegui, Cesar ;
Leclipteux, Thierry ;
Mertens, Pascal ;
Dujardin, Jean-Claude ;
Herdewijn, Piet ;
Buescher, Philippe .
JOURNAL OF INFECTIOUS DISEASES, 2008, 198 (10) :1565-1572
[8]   Oligonucleotide-functionalized gold nanoparticles as probes in a dry-reagent strip biosensor for DNA analysis by hybridization [J].
Glynou, K ;
Ioannou, PC ;
Christopoulos, TK ;
Syriopoulou, V .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4155-4160
[9]   Practical considerations in design of internal amplification controls for diagnostic PCR assays [J].
Hoorfar, J ;
Malorny, B ;
Abdulmawjood, A ;
Cook, N ;
Wagner, M ;
Fach, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (05) :1863-1868
[10]   Dry-reagent disposable dipstick test for visual screening of seven leukemia-related chromosomal translocations [J].
Kalogianni, Despina P. ;
Bravou, Vasiliki ;
Christopoulos, Theodore K. ;
Ioannou, Penelope C. ;
Zoumbos, Nicholas C. .
NUCLEIC ACIDS RESEARCH, 2007, 35 (04)