Effect of LVAD Outlet Graft Anastomosis Angle on the Aortic Valve, Wall, and Flow

被引:30
作者
Inci, Gizem [1 ]
Sorguven, Esra [1 ]
机构
[1] Yeditepe Univ, Dept Mech Engn, TR-34755 Istanbul, Turkey
关键词
VENTRICULAR ASSIST DEVICE; BLOOD PUMP; SIMULATION; LOCATION; PATTERNS; CANNULA;
D O I
10.1097/MAT.0b013e3182578b6a
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Left ventricular assist devices (LVADs), which pump blood from the left ventricle to the aorta are an important therapy option for patients with end-stage cardiovascular diseases. Recent publications show that even with optimized LVADs fatal complications can occur because of the blood deformations around the inflow cannula or through the LVAD outlet graft-aorta anastomosis. This study investigates the effects of the anastomosis geometry on the flow through the aorta, on the pressure and wall shear stress (WSS) distributions on the aortic wall and on the total entropy generation in the anastomosis region. Anastomosis geometry is defined with two angles, one on the coronal plane and the other on the transversal plane. Turbulent flow simulations are performed for each geometry. Results indicate that 3% to 5% of the work given by the LVAD is dissipated because of the viscous losses in the anastomosis region. The entropy generation, as well as the maximum WSS, increases as the inclination angle decreases. Some portion of the blood streaming out of the LVAD conduit flows toward the aortic valve; therefore the reverse-flow region extends up to the aortic valve in some cases, which may be one of the causes of aortic-valve dysfunction. Results of this study provide insight on the importance of the anastomosis geometry on the hemodynamics in the aorta and downstream the aortic valve, stresses on the aortic wall, and viscous losses. ASAIO Journal 2012;58:373-381.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 24 条
[11]  
Kar B, 2005, TEX HEART I J, V32, P294
[12]  
Kaufmann F, 2006, BRUSS INT SOC ROT BL
[13]   Effects of left ventricular assist device support and outflow graft location upon aortic blood flow [J].
Litwak, KN ;
Koenig, SC ;
Tsukui, H ;
Kihara, S ;
Wu, ZJ ;
Pantalos, GM .
ASAIO JOURNAL, 2004, 50 (05) :432-437
[14]   Flow through an outlet cannula of a rotary ventricular assist device [J].
Manning, KB ;
Miller, GE .
ARTIFICIAL ORGANS, 2002, 26 (08) :714-723
[15]   Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta [J].
May-Newman, K ;
Hillen, B ;
Dembitsky, W .
ASAIO JOURNAL, 2006, 52 (02) :132-139
[16]  
Newman K. D. May, 2004, Journal of Medical Engineering & Technology, V28, P105, DOI 10.1080/0309190042000193865
[17]  
Muthiah K, 2011, HEART LUNG CIRC, V20, pS63
[18]   Neonatal Aortic Arch Hemodynamics and Perfusion During Cardiopulmonary Bypass [J].
Pekkan, Kerem ;
Dur, Onur ;
Sundareswaran, Kartik ;
Kanter, Kirk ;
Fogel, Mark ;
Yoganathan, Ajit ;
Undar, Akif .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (06)
[19]   Influence of inflow cannula length in axial-flow pumps on neurologic adverse event rate:: Results from a multi-center analysis [J].
Schmid, Christof ;
Jurmann, Michael ;
Birnbaum, Dietrich ;
Colombo, Tiziano ;
Falk, Volkmar ;
Feltrin, Giuseppe ;
Garatti, Andrea ;
Genoni, Michele ;
Gerosa, Gino ;
Goettel, Peter ;
Gummert, Jan ;
Halfmann, Robert ;
Hammel, Dieter ;
Hennig, Ewald ;
Kaufmann, Friedrich ;
Lanfranconi, Marco ;
Meyns, Bart ;
Mohr, Friedrich ;
Mueller, Johannes ;
Nikolov, Dimitar ;
Rucinskas, Kestutis ;
Scheld, Hans-Heinrich ;
Schmid, Franz-Xaver ;
Schneider, Michael ;
Sirvydis, Vytautas ;
Tandler, Rene ;
Vitali, Ettore ;
Vlasselaers, Dirk ;
Weyand, Michael ;
Wilhelm, Markus ;
Hetzer, Roland .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (03) :253-260
[20]  
Stewart SFC, 2010, NOZZLE MODEL