摘要
Contrast-enhanced ultrasound (CEUS) imaging has great potential for use in new ultrasound clinical applications such as myocardial perfusion imaging and abdominal lesion characterization. In CEUS imaging, contrast agents (i.e., microbubbles) are used to improve contrast between blood and tissue because of their high nonlinearity under low ultrasound pressure. However, the quality of CEUS imaging sometimes suffers from a low signal-to-noise ratio (SNR) in deeper imaging regions when a low mechanical index (MI) is used to avoid microbubble disruption, especially for imaging at off-resonance transmit frequencies. In this paper, we propose a new strategy of combining CEUS sequences with the recently proposed multiplane-wave (MW) compounding method to improve the SNR of CEUS in deeper imaging regions without increasing MI or sacrificing frame rate. The MW-CEUS method emits multiple Hadamard-coded CEUS pulses in each transmission event (i.e.,pulse-echo event). The received echo signals first undergo fundamental bandpass filtering (i.e., the filter is centered on the transmit frequency) to eliminate the microbubble's second-harmonic signals because they cannot be encoded by pulse inversion. The filtered signals are then Hadamard decoded and realigned in fast time to recover the signals as they would have been obtained using classic CEUS pulses, followed by designed recombination to cancel the linear tissue responses. The MW-CEUS method significantly improved contrast-to-tissue ratio and SNR of CEUS imaging by transmitting longer coded pulses. The image resolution was also preserved. The microbubble disruption ratio and motion artifacts in MW-CEUS were similar to those of classic CEUS imaging. In addition, the MW-CEUS sequence can be adapted to other transmission coding formats. These properties of MW-CEUS can potentially facilitate CEUS imaging for many clinical applications, especially assessing deep abdominal organs or the heart.
引用
收藏
页码:178 / 187
页数:10
相关论文
共 24 条
[1]   Pulse inversion imaging of liver blood flow - Improved method for characterizing focal masses with microbubble contrast [J].
Burns, PN ;
Wilson, SR ;
Simpson, DH .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :58-71
[2]  
Cobbold R. S. C., 2007, Foundations of biomedical ultrasound
[3]   Ultrasound Contrast Plane Wave Imaging [J].
Couture, Olivier ;
Fink, Mathias ;
Tanter, Mickael .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (12) :2676-2683
[4]   ULTRAFAST IMAGING OF ULTRASOUND CONTRAST AGENTS [J].
Couture, Olivier ;
Bannouf, Souad ;
Montaldo, Gabriel ;
Aubry, Jean-Francois ;
Fink, Mathias ;
Tanter, Mickael .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (11) :1908-1916
[5]   Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power [J].
Eckersley, RJ ;
Chin, CT ;
Burns, PN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (02) :213-219
[6]   Microbubble contrast agent detection using binary coded pulses [J].
Eckersley, Robert J. ;
Tang, Meng-Xing ;
Chetty, Kevin ;
Hajnal, Joseph V. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (11) :1787-1795
[7]   Characterization and evaluation of tissue-mimicking gelatin phantoms for use with MRgFUS [J].
Farrer, Alexis I. ;
Odeen, Henrik ;
de Bever, Joshua ;
Coats, Brittany ;
Parker, Dennis L. ;
Payne, Allison ;
Christensen, Douglas A. .
JOURNAL OF THERAPEUTIC ULTRASOUND, 2015, 3
[8]   Arbitrary Waveforms using a Tri-State Transmit Pulser [J].
Flynn, John A. ;
Kaczkowski, Peter ;
Linkhart, Ken ;
Daigle, Ronald E. .
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, :41-44
[9]   Ultrafast Synthetic Transmit Aperture Imaging Using Hadamard-Encoded Virtual Sources With Overlapping Sub-Apertures [J].
Gong, Ping ;
Song, Pengfei ;
Chen, Shigao .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (06) :1372-1381
[10]   Delay-Encoded Harmonic Imaging (DE-HI) in Multiplane-Wave Compounding [J].
Gong, Ping ;
Song, Pengfei ;
Chen, Shigao .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (04) :952-959