Emphysema Quantification by Low-Dose CT: Potential Impact of Adaptive Iterative Dose Reduction Using 3D Processing

被引:40
作者
Nishio, Mizuho [1 ]
Matsumoto, Sumiaki [1 ]
Ohno, Yoshiharu [1 ]
Sugihara, Naoki [2 ]
Inokawa, Hiroyasu [2 ]
Yoshikawa, Takeshi [1 ]
Sugimura, Kazuro [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Radiol, Chuo Ku, Kobe, Hyogo 6500017, Japan
[2] Toshiba Med Syst Corp, Otawara, Tochigi, Japan
关键词
emphysema; low-dose CT; quantification; PULMONARY-FUNCTION TESTS; COMPUTED-TOMOGRAPHY; CHEST CT; MICROSCOPIC MORPHOMETRY; OBJECTIVE QUANTIFICATION; RADIATION-EXPOSURE; MULTIDETECTOR CT; DENSITY MASK; LUNG; IMAGES;
D O I
10.2214/AJR.11.8174
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to investigate the effect of a novel reconstruction algorithm, adaptive iterative dose reduction using 3D processing, on emphysema quantification by low-dose CT. MATERIALS AND METHODS. Twenty-six patients who had undergone standard-dose (150 mAs) and low-dose (25 mAs) CT scans were included in this retrospective study. Emphysema was quantified by several quantitative measures, including emphysema index given by the percentage of lung region with low attenuation (lower than -950 HU), the 15th percentile of lung density, and size distribution of low-attenuation lung regions, on standard-dose CT images reconstructed without adaptive iterative dose reduction using 3D processing and on low-dose CT images reconstructed both without and with adaptive iterative dose reduction using 3D processing. The Bland-Altman analysis was used to assess whether the agreement between emphysema quantifications on low-dose CT and on standard-dose CT was improved by the use of adaptive iterative dose reduction using 3D processing. RESULTS. For the emphysema index, the mean differences between measurements on low-dose CT and on standard-dose CT were 1.98% without and -0.946% with the use of adaptive iterative dose reduction using 3D processing. For 15th percentile of lung density, the mean differences without and with adaptive iterative dose reduction using 3D processing were -6.67 and 1.28 HU, respectively. For the size distribution of low-attenuation lung regions, the ranges of the mean relative differences without and with adaptive iterative dose reduction using 3D processing were 21.4-85.5% and -14.1% to 11.2%, respectively. For 15th percentile of lung density and the size distribution of low-attenuation lung regions, the agreement was thus improved by the use of adaptive iterative dose reduction using 3D processing. CONCLUSION. The use of adaptive iterative dose reduction using 3D processing resulted in greater consistency of emphysema quantification by low-dose CT, with quantification by standard-dose CT.
引用
收藏
页码:595 / 601
页数:7
相关论文
共 34 条
[1]   Pulmonary emphysema: Subjective visual grading versus objective quantification with macroscopic morphometry and thin-section CT densitometry [J].
Bankier, AA ;
De Maertelaer, V ;
Keyzer, C ;
Gevenois, PA .
RADIOLOGY, 1999, 211 (03) :851-858
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Automated CT image evaluation of the lung:: A morphology-based concept [J].
Blechschmidt, RA ;
Werthschützky, R ;
Lörcher, U .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (05) :434-442
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[6]   Comparison of computed density and microscopic morphometry in pulmonary emphysema [J].
Gevenois, PA ;
DeVuyst, P ;
deMaertelaer, V ;
Zanen, J ;
Jacobvitz, D ;
Cosio, MG ;
Yernault, JC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (01) :187-192
[7]   Comparison of standard- and low-radiation-dose CT for quantification of emphysema [J].
Gierada, David S. ;
Pilgram, Thomas K. ;
Whiting, Bruce R. ;
Hong, Cheng ;
Bierhals, Andrew J. ;
Kim, Jin Hwan ;
Bae, Kyongtae T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :42-47
[8]   Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images [J].
Hu, SY ;
Hoffman, EA ;
Reinhardt, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (06) :490-498
[9]   Lung cancer screening: Minimum tube current required for helical CT [J].
Itoh, S ;
Ikeda, M ;
Arahata, S ;
Kodaira, T ;
Isomura, T ;
Kato, T ;
Yamakawa, K ;
Maruyama, K ;
Ishigaki, T .
RADIOLOGY, 2000, 215 (01) :175-183
[10]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628