Prevalence and Clinical Consequences of Fracture and Fragment Migration of the Bard G2 Filter: Imaging and Clinical Follow-up in 684 Implantations

被引:25
作者
An, Tianzhi [1 ]
Moon, Eunice [1 ]
Bullen, Jennifer [2 ,3 ]
Kapoor, Baljendra [1 ]
Wu, Alex [1 ]
Sands, Mark [1 ]
Wang, Weiping [1 ]
机构
[1] Cleveland Clin, Imaging Inst, Cleveland, OH 44195 USA
[2] Cleveland Clin, Sect Intervent Radiol, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Quantitat Hlth Sci, Cleveland, OH 44195 USA
关键词
VENA-CAVA FILTERS; RIGHT-VENTRICULAR MIGRATION; RECOVERY FILTER; TECHNICAL SUCCESS; VEIN THROMBOSIS; OUTCOMES; REMOVAL; PERFORATION; RETRIEVAL; SAFETY;
D O I
10.1016/j.jvir.2014.01.035
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the prevalence and clinical sequelae of G2 filter (Bard Peripheral Vascular, Tempe, Arizona) fractures and fragment migration. Materials and Methods: Patients who underwent G2 filter placement between October 2005 and February 2010 were assessed for filter fractures and complications. Fracture prevalence was estimated at various time points based On data from patients with known fracture status. Results: Among 829 patients who underwent G2 filter placement, 684 had follow-up imaging and qualified for the study (381 men and 303 women; average age, 60.3 y; range, 15.8-95.2 y). For 541 (79%) patients, at least one image was available that contained the filter (imaging follow-up interval, 14.9 mo +/- 20.0; range, 0-78.6 mo); images that did not include the filter but may have shown the migrated fracture fragment were available for 143 (21%) patients (follow-up interval, 11.2 mo +/- 19.3; range, 0-83.4 mo). There were 16 fractured limbs identified in 13 patients (incidence, 1.9%; follow-up interval, 30.4 mo +/- 18.7; range, 5.5-76.5 mo). Fracture fragments were identified in the pulmonary arteries (n = 4); right ventricle (n = 2); pericardium (n = 1), iliac vein (n = 1), and kidney (n = 1). Four fracture limbs remained near the filter; the remaining three could not be located. All patients with filter fracture were asymptomatic. The estimated 5-year fracture prevalence was 38% (95% confidence interval, 22.9%, 54.8%), Conclusions: The early occurrence of G2 filter fractures was low, but the incidence increased over time. No life-threatening events occurred in patients with filter fracture during the study time frame.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 30 条
[1]   Approximate is better than "exact" for interval estimation of binomial proportions [J].
Agresti, A ;
Coull, BA .
AMERICAN STATISTICIAN, 1998, 52 (02) :119-126
[2]   Systematic Review of the Use of Retrievable Inferior Vena Cava Filters [J].
Angel, Luis F. ;
Tapson, Victor ;
Galgon, Richard E. ;
Restrepo, Marcos I. ;
Kaufman, John .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (11) :1522-1530
[3]   Technical Success and Safety of Retrieval of the G2 Filter in a Prospective, Multicenter Study [J].
Binkert, Christoph A. ;
Drooz, Alain T. ;
Caridi, James G. ;
Sands, Mark J. ;
Bjarnason, Haraldur ;
Lynch, Frank C. ;
Rilling, William S. ;
Zambuto, Domenic A. ;
Stavropoulos, S. William ;
Venbrux, Anthony C. ;
Kaufman, John A. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (11) :1449-1453
[4]   Right ventricular migration and endovascular removal of an inferior vena cava filter [J].
Bui, James T. ;
West, Derek L. ;
Pinto, Christina ;
Gramling-Babb, Patricia ;
Owens, Charles A. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (01) :141-144
[5]   Aortic Penetration by Temporary Inferior Vena Cava Filters: Report of an Interesting Case and Review of the Literature [J].
Caceres, Manuel ;
Braud, Rebecca ;
Weiman, Darryl .
VASCULAR AND ENDOVASCULAR SURGERY, 2012, 46 (02) :181-186
[6]   Caudal migration of a G2 filter during carbon dioxide cavography [J].
Cantwell, Colin P. ;
Lynch, Frank C. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (06) :814-815
[7]   Comparison of the Recovery and G2 Filter as Retrievable Inferior Vena Cava Filters [J].
Cantwell, Colin P. ;
Pennypacker, Jason ;
Singh, Harjit ;
Scorza, Leslie B. ;
Waybill, Peter N. ;
Lynch, Frank C. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (09) :1193-1199
[8]   G2 Inferior Vena Cava Filter: Retrievability and Safety [J].
Charles, Hearns W. ;
Black, Michelle ;
Kovacs, Sandor ;
Gohari, Arash ;
Arampulikan, Joseph ;
McCann, Jeffrey W. ;
Clark, Timothy W. I. ;
Bashar, Mona ;
Steiger, David .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (08) :1046-1051
[9]   Use of a Retrievable Vena Cava Filter with Low-intensity Anticoagulation for Prevention of Pulmonary Embolism in Patients with Cancer: An Observational Study in 106 Cases [J].
Damascelli, Bruno ;
Ticha, Vladimira ;
Patelli, Gianluigi ;
Lanocita, Rodolfo ;
Morosi, Carlo ;
Civelli, Enrico ;
Di Tolla, Giuseppe ;
Frigerio, Laura Francesca ;
Ciceri, Elisa ;
Garbagnati, Francesco ;
Spreafico, Carlo ;
Amadeo, Paola ;
Marchiano, Alfonso .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (09) :1312-1319
[10]   Fragmentation, Embolization, and Left Ventricular Perforation of a Recovery Filter [J].
Desjardins, Benoit ;
Kamath, Sadashiv H. ;
Williams, David .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (08) :1293-1296