Thermal design guidelines of solar power towers

被引:164
作者
Rodriguez-Sanchez, M. R. [1 ]
Soria-Verdugo, Antonio [1 ]
Antonio Almendros-Ibanez, Jose [2 ,3 ]
Acosta-Iborra, Antonio [1 ]
Santana, Domingo [1 ]
机构
[1] Univ Carlos III Madrid, Dept Thermal & Fluid Engn, Madrid 28911, Spain
[2] Univ Castilla La Mancha, Escuela Ingn Ind Albacete, Dept Appl Mech & Projects Engn, Albacete 02071, Spain
[3] Renewable Energy Res Inst, Sect Solar & Energy Efficiency, Albacete 02071, Spain
关键词
Solar power tower; Molten-salt central-receiver; Film temperature; Radiation effective temperature; Tube corrosion; Thermal stress; RECEIVER; SIMULATION; TUBE;
D O I
10.1016/j.applthermaleng.2013.11.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of the main problems of solar power tower plants with molten salt as heat transfer fluid is the reliability of central receivers. The receiver must withstand high working temperatures, molten salt corrosion and important solar flux transients that lead to thermal stresses and fatigue. Despite these difficulties, it is necessary an estimation of the receiver thermal efficiency in order to have an accurate estimation of the investment cost of the solar plant and to assure the lifetime estimation of the receiver. A thermal, mechanical and hydrodynamic analysis of these receivers has been developing in this work, assuming constant heat flux in each axial discretized section of the tube wall but considering circumferential temperature variations in the perimeter of the tubes caused by the difference between the heat flux received by the front part of the tubes and by the rear part. The thermal analysis shows that the radiation losses are higher than in literature, and consequently the thermal efficiency is lower too. This is due to the fact that the effective tube wall temperature for radiation is higher than the mean tube wall temperature, especially if the rear temperature of the tubes is considered. Besides, it has been found that the highest temperatures and thermal stresses are sited on the eastern and western panels of the receivers. Film temperature is the most limiting parameter for the receiver design due to it is responsible for salt decomposition and tube corrosion. Therefore, once the tube material is chosen, the film temperature cannot exceed a critical value over which the corrosion ratio raises rapidly. Small tube diameters and low number of panels results in low film temperatures, although this kind of design increases the pressure drop. Therefore, a compromise between film temperature and pressure drop can lead to a receiver design that ensures its lifetime, and at the same time, optimizes the investment and operational cost of the receiver. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:428 / 438
页数:11
相关论文
共 50 条
  • [31] Integration between supercritical CO2 Brayton cycles and molten salt solar power towers: A review and a comprehensive comparison of different cycle layouts
    Wang, Kun
    He, Ya-Ling
    Zhu, Han-Hui
    APPLIED ENERGY, 2017, 195 : 819 - 836
  • [32] Design analysis of solar parabolic trough thermal collectors
    Hafez, A. Z.
    Attia, A. M.
    Eltwab, H. S.
    ElKousy, A. O.
    Afifi, A. A.
    AbdElhamid, A. G.
    AbdElqader, A. N.
    Fateen, S-E. K.
    El-Metwally, K. A.
    Soliman, A.
    Ismail, I. M.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 : 1215 - 1260
  • [33] Influence of sunshape and optical error on spillover of concentrated flux in solar thermal power tower plant
    Song, Jifeng
    Yang, Genben
    Wang, Haiyu
    Niu, Yisen
    Hou, Hongjuan
    Su, Ying
    Wang, Qian
    Zou, Zubing
    ENERGY, 2022, 256
  • [34] DESIGN AND MODELING CONTROL SYSTEM FOR A SOLAR POWER PLANT
    Jahromi, M. Hosein Mehraban
    Dehghan, Bahram
    Jahromi, Ali Mehraban
    Zarie, S. Faride
    SECOND INTERNATIONAL CONFERENCE ON COMPUTER AND ELECTRICAL ENGINEERING, VOL 2, PROCEEDINGS, 2009, : 27 - +
  • [35] High-temperature liquid-fluoride-salt closed-Brayton-cycle solar power towers
    Forsberg, Charles W.
    Peterson, Per F.
    Zhao, Haihua
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (02): : 141 - 146
  • [36] Urban Design Guidelines for Improvement of Outdoor Thermal Comfort in Tropical Cities
    Ruefenacht, Lea A.
    Adelia, Ayu S.
    Acero, Juan A.
    Nevat, Ido
    CYBERGEO-EUROPEAN JOURNAL OF GEOGRAPHY, 2022,
  • [37] Modeling of Dish-Stirling Solar Thermal Power Generation
    Howard, Dustin
    Harley, Ronald G.
    IEEE PES GENERAL MEETING, 2010,
  • [38] Testing the thermal performance of water cooling towers
    El-Morshedy, Salah El-Din
    Shouman, Loula
    KERNTECHNIK, 2024, 89 (05) : 683 - 689
  • [39] Transient simulation for developing a combined solar thermal power plant
    Niknia, Iman
    Yaghoubi, Mahmood
    APPLIED THERMAL ENGINEERING, 2012, 37 : 196 - 207
  • [40] Simulations in Development of Nonlinear Control for a Solar Thermal Power Plant
    Juuso, Esko K.
    Yebra, Luis J.
    IFAC PAPERSONLINE, 2024, 58 (13): : 302 - 307