A transesophageal echocardiographic and cine-fluoroscopic evaluation of an ATS prosthetic valve opening

被引:4
作者
Sezai, Akira [1 ]
Umeda, Tomofumi [1 ]
Hata, Mitsumasa [1 ]
Niino, Tetsuya [1 ]
Unosawa, Satoshi [1 ]
Tokai, Kotaro [2 ]
Kasamaki, Yuji [2 ]
Minami, Kazutomo [1 ]
机构
[1] Nihon Univ, Sch Med, Dept Cardiovasc Surg, Itabashi Ku, Tokyo 1738610, Japan
[2] Nihon Univ, Sch Med, Dept Cardiol, Itabashi Ku, Tokyo 1738610, Japan
关键词
Prosthetic valve; Valve replacement; Transesophageal echocardiography; HEART-VALVE; AORTIC POSITION; EXPERIENCE; THROMBOSIS;
D O I
10.1007/s00595-008-3895-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
The effectiveness of the ATS valves includes their durability and the quietness of the valve sound. However, a cine-fluoroscopic study revealed an incomplete opening of the valve leaflet. An overall evaluation of the ATS valve was conducted by transesophageal echocardiography. The patients were divided into two groups based on the opening angle (OA): Group A, with a maximum OA of 80A degrees or greater and Group B, with a maximum OA of under 80A degrees. In Group A, the peak pressure gradient (PPG) sites of the anterior, central and posterior mitral commissure were 8.17, 8.05, and 8.09 mmHg, respectively, with no significant differences among the three sites. Similar results were obtained for Group B; the PPG at the three respective measurement sites were 8.59, 8.43, and 8.51 mmHg, and the differences were not statistically significant. No statistically significant differences were observed in the mean pressure gradient or pressure half time among the three measurement sites or between the two patient groups. Although, in many cases, the ATS valves did not open completely, the incomplete valve opening did not pose any problems in the valve function itself or in the cardiac functions of the patients.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 14 条
[1]  
Aoyagi S, 1997, J HEART VALVE DIS, V6, P258
[2]   Leaflet movement of the ATS valve in the aortic position: Unique behavior observed in 19-mm valves [J].
Aoyagi, Shigeaki ;
Arinaga, Koichi ;
Fukunaga, Shuji ;
Tayama, Eiki ;
Kosuga, Tomokazu ;
Akashi, Hidetoshi .
ANNALS OF THORACIC SURGERY, 2006, 82 (03) :853-857
[3]  
Bach David S., 2000, Cardiology Clinics, V18, P751, DOI 10.1016/S0733-8651(05)70178-8
[4]   Eleven-year single-center experience with the ATS Open Pivot bileaflet heart valve [J].
Baykut, Doan ;
Grize, Leticia ;
Schindler, Christian ;
Keil, Angelika S. ;
Bernet, Franziska ;
Zerkowski, Hans-Reinhard .
ANNALS OF THORACIC SURGERY, 2006, 82 (03) :847-852
[5]  
Emery RW, 2004, J HEART VALVE DIS, V13, P231
[6]  
Hasegawa M, 2000, Ann Thorac Cardiovasc Surg, V6, P247
[7]  
Jazayeri S, 2003, J HEART VALVE DIS, V12, P628
[8]   Role of cine-fluoroscopy, transthoracic, and transesophageal echocardiography in patients with suspected prosthetic heart valve thrombosis [J].
Montorsi, P ;
De Bernardi, F ;
Muratori, M ;
Cavoretto, D ;
Pepi, M .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (01) :58-64
[9]   Evaluation of valve sound and its effects on ATS prosthetic valves in patients' quality of life [J].
Sezai, A ;
Shiono, M ;
Orime, Y ;
Hata, H ;
Yagi, S ;
Negishi, N ;
Sezai, Y .
ANNALS OF THORACIC SURGERY, 2000, 69 (02) :507-512
[10]  
Sezai Akira, 2006, Ann Thorac Cardiovasc Surg, V12, P249