Comparison of breath-hold 2D phase-contrast with non breath-hold cine phase-contrast MRA in the assessment of azygos venous blood flow in portal hypertension

被引:20
作者
Ng, WH [1 ]
Chan, YL
Sung, JY
Lee, YT
Lee, SF
Chung, SSC
机构
[1] Prince Wales Hosp, Dept Diagnost Radiol & Organ Imaging, Shatin, Hong Kong, Peoples R China
[2] Prince Wales Hosp, Dept Med & Therapeut, Shatin, Hong Kong, Peoples R China
[3] Prince Wales Hosp, Dept Surg, Shatin, Hong Kong, Peoples R China
关键词
MRA; azygos venous flow; cirrhosis varices;
D O I
10.1007/s10334-003-0026-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Azygos venous blood flow as an index of blood flow through the gastroesophageal collaterals and varices is of value in the prediction of gastrointestinal bleeding. Measurement of azygos venous blood flow has been achieved by non breath-hold (NBH) cine phase-contrast magnetic resonance imaging. The objective of this study was to compare the faster breath-hold (BH) phase-contrast technique with the standard (NBH) cine phase-contrast technique in the measurement of azygos blood flow. Thirty-two cirrhotic patients with esophageal varices were examined by magnetic resonance imaging using a BH technique and a NBH cine phase-contrast technique to measure the flow velocity, flow volume and calibre of the azygos vein at the mid-right atrial level. The flow values were obtained on the velocity image of the phase-contrast study. Values obtained from the two methods were evaluated statistically for the strength and significance of correlation by the Pearson test. Measurement by the BH method performed at full-inspiration as well as end-expiration was also obtained in 15 healthy volunteers. The breath-hold phase-contrast method has significant but weak correlation with non BH cine phase-contrast method in the measurement of azygos venous blood flow volume (r = 0.55 p<0.01) and flow velocity (r = 0.43, p = 0.01). However, the calibre of the azygos vein gave a strong correlation in these two methods (0.82). In the subgroup of patients whose azygos blood flow velocity was greater than 7.4 cm/s, the correlation of azygos blood flow volume is strong (r = 0.80, p<0.01). The azygos vein calibre remains highly correlated between the BH and NBH method, in both high flow velocity (r = 0.73) and low flow velocity (r = 0.83) groups. Breath-hold sequence leads to higher values for flow velocity and flow volume in the cirrhotic patients and also the control group. In patients with portal hypertension, BH 2D phase-contrast (PC) magnetic resonance angiography (MRA) could give a comparable estimation of the calibre of the azygos vein as the NBH 2D cine PC MRA but not for azygos flow volume. In patients with high azygos flow velocity, the strong correlation in flow volume between the BH and NBH method suggests that the BH method may be a time-saving alternative to the NBH method.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 14 条
[1]  
AHMED G, 1996, JMRI-J MAGN RESON IM, V1, P90
[2]  
AMY K, 1996, JMRI-J MAGN RESON IM, V1, P94
[3]   ULTRASONOGRAPHY IN THE DIAGNOSIS OF PORTAL-HYPERTENSION - DIMINISHED RESPONSE OF PORTAL VESSELS TO RESPIRATION [J].
BOLONDI, L ;
GANDOLFI, L ;
ARIENTI, V ;
CALETTI, GC ;
CORCIONI, E ;
GASBARRINI, G ;
LABO, G .
RADIOLOGY, 1982, 142 (01) :167-172
[4]   PORTAL-HYPERTENSION [J].
BOSCH, J ;
NAVASA, M ;
GARCIAPAGAN, JC ;
DELACY, AM ;
RODES, J .
MEDICAL CLINICS OF NORTH AMERICA, 1989, 73 (04) :931-953
[5]   MEASUREMENT OF AZYGOUS VENOUS-BLOOD FLOW IN THE EVALUATION OF PORTAL-HYPERTENSION IN PATIENTS WITH CIRRHOSIS - CLINICAL AND HEMODYNAMIC CORRELATIONS IN 100 PATIENTS [J].
BOSCH, J ;
MASTAI, R ;
KRAVETZ, D ;
BRUIX, J ;
RIGAU, J ;
RODES, J .
JOURNAL OF HEPATOLOGY, 1985, 1 (02) :125-139
[6]  
DAVID J, 1995, RADILOGY, V195, P101
[7]  
DAVID J, 1993, RADIOLOGY, V187, P407
[8]  
Debatin JF, 1996, HEPATOLOGY, V24, P1109
[9]   Use of color Doppler EUS in assessing azygos blood flow for patients with portal hypertension [J].
Lee, YT ;
Sung, JJY ;
Yung, MY ;
Yu, ALM ;
Chung, SCS .
GASTROINTESTINAL ENDOSCOPY, 1999, 50 (01) :47-52
[10]   NONINVASIVE MEASUREMENT OF AZYGOS VENOUS-BLOOD FLOW USING MAGNETIC-RESONANCE [J].
LOMAS, DJ ;
HAYBALL, MP ;
JONES, DP ;
SIMS, C ;
ALLISON, MED ;
ALEXANDER, GJM .
JOURNAL OF HEPATOLOGY, 1995, 22 (04) :399-403