Molecularly imprinted electrochemical sensor based on poly (o-phenylenediamine-co-o-aminophenol) incorporated with poly (styrenesulfonate) doped poly(3,4-ethylenedioxythiophene) ferrocene composite modified screen-printed carbon electrode for highly sensitive and selective detection of prostate cancer biomarker

被引:19
作者
Khumngern, Suntisak [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,3 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Bejrananda, Tanan [4 ]
Numnuam, Apon [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Ctr Excellence Trace Anal & Biosensor, Hat Yai 90110, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Div Phys Sci, Hat Yai 90110, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90110, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Med, Dept Surg, Urol Unit, Hat Yai 90110, Songkhla, Thailand
关键词
Molecularly imprinted polymer; Electrochemical sensor; Prostate-specific antigen; Ferrocene; Poly(o-phenylenediamine-co-o-aminophenol); ANTIGEN PSA; ACID; COPOLYMERIZATION; IMMUNOSENSOR; ELISA; ASSAY;
D O I
10.1016/j.microc.2022.107311
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A molecularly imprinted polymer (MIP) of o-phenylenediamine (o-PD) and o-aminophenol (o-AP), electropolymerized in the presence of prostate specific antigen (PSA), was deposited on a screen-printed carbon electrode (SPCE) modified with a poly(styrenesulfonate) doped poly(3,4-ethylenedioxythiophene) ferrocene composite (PEDOT:PSS@Fc) to create a MIP/PEDOT:PSS@Fc/SPCE electrochemical sensor. The MIP layer was characterized by scanning electron microscopy (SEM). PSA was determined using differential pulse voltammetry by measuring the change in the oxidation peak current of Fc. At the optimal monomer molar ratio, electro-polymerization condition, phosphate buffer pH and rebinding time, the MIP sensor produced a linear response over a concentration range of 1.0 x 10(-7)-1.0 x 10(-4) ng mL(-1) PSA. The detection limit was (8.3 +/- 1.3) x 10(-8) ng mL(-1) and selectivity, reproducibility, reusability over 12 cycles and long-term stability over 7 weeks were good. Using the Langmuir adsorption isotherm, the dissociation constant (K-D) of the MIP sensor was 1.91 x 10(-6) ng mL(-1). PSA levels detected in blood serum with the present sensor were consistent with the data from the electrochemiluminescence immunoassay (P > 0.05).
引用
收藏
页数:10
相关论文
共 47 条
  • [1] Development of a reliable bioanalytical method based on prostate specific antigen trapping on the cavity of molecular imprinted polymer towards sensing of PSA using binding affinity of PSA-MIP receptor: A novel biosensor
    Abbasy, Leila
    Mohammadzadeh, Arezoo
    Hasanzadeh, Mohammad
    Razmi, Nasrin
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 188
  • [2] Development and validation of a quantitative ELISA for the measurement of PSA concentration
    Acevedo, B
    Perera, Y
    Ruiz, M
    Rojas, G
    Benítez, J
    Ayala, M
    Gavilondo, J
    [J]. CLINICA CHIMICA ACTA, 2002, 317 (1-2) : 55 - 63
  • [3] Synthesis and characterization of molecularly imprinted polymer of N-maleoylchitosan-grafted-2-acrylamido-2-methylpropanesulfonic acid and its controlled delivery and recognition of bovine serum albumin
    Anirudhan, T. S.
    Sandeep, S.
    [J]. POLYMER CHEMISTRY, 2011, 2 (09) : 2052 - 2061
  • [4] AOAC International, 2016, APP F GUID STAND MET
  • [5] Single chip SPR and fluorescent ELISA assay of prostate specific antigen
    Breault-Turcot, J.
    Poirier-Richard, H. -P.
    Couture, M.
    Pelechacz, D.
    Masson, J. -F.
    [J]. LAB ON A CHIP, 2015, 15 (23) : 4433 - 4440
  • [6] RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994)
    BUCK, RP
    LINDNER, E
    [J]. PURE AND APPLIED CHEMISTRY, 1994, 66 (12) : 2527 - 2536
  • [7] Electrochemical sensor based on molecularly imprinted poly(ortho-phenylenediamine) for determination of hexahydrofarnesol in aviation biokerosene
    Buffon, Edervaldo
    Stradiotto, Nelson Ramos
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 287 : 371 - 379
  • [8] A novel electrochemical immunosensor for highly sensitive detection of prostate-specific antigen using 3D open-structured PtCu nanoframes for signal amplification
    Chen, Yao
    Yuan, Pei-Xin
    Wang, Ai-Jun
    Luo, Xiliang
    Xue, Yadong
    Zhang, Lu
    Feng, Jiu-Ju
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 126 : 187 - 192
  • [9] An ultrasensitive label-free electrochemical immunosensor based on 3D porous chitosan-graphene-ionic liquid-ferrocene nanocomposite cryogel decorated with gold nanoparticles for prostate-specific antigen
    Choosang, Jittima
    Khumngern, Suntisak
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    [J]. TALANTA, 2021, 224
  • [10] Ultrasensitive electrochemical detection of prostate-specific antigen (PSA) using gold-coated magnetic nanoparticles as 'dispersible electrodes'
    Chuah, Kyloon
    Lai, Leo M. H.
    Goon, Ian Y.
    Parker, Stephen G.
    Amal, Rose
    Gooding, J. Justin
    [J]. CHEMICAL COMMUNICATIONS, 2012, 48 (29) : 3503 - 3505