Gradient Calibration for the RCBHT Cantilever Snap Verification System.

被引:0
作者
Rojas, J. [1 ]
Harada, K. [1 ]
Onda, H. [1 ]
Yamanobe, N. [1 ]
Yoshida, E. [1 ]
Nagata, K. [1 ]
Kawai, Y. [1 ]
机构
[1] AIST, Intelligent Sys Res Inst, Tsukuba, Ibaraki 3058568, Japan
来源
2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2012) | 2012年
关键词
D O I
暂无
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
In this work a gradient calibration method was presented as part of the Relative-Change-Based-Hierarchical Taxonomy (RCBHT) cantilever-snap verification system and the Pivot Approach control strategy for the automation of cantilever-snaps. As part of a relative-change based force signal interpretation scheme, an effective gradient calibration process is needed to increase the RCBHT's system robustness. Prior to this work, all gradient classification schemes were derived on an intuitive trial and error basis. Statistical measures were used to derive contact and constant gradient thresholds in contextually sensitive ways. The method requires training assemblies to identify a minimum contact gradient which serves as a marker for all other gradient thresholds. Experimental procedures verified that our calibration method was effective. Assemblies with supervised successful outcomes were used in experimentation. The RCBHT assessed out assemblies as successful using the calibration method. Even two snaps that where classified falsely as unsuccessful when using a previously non-calibrated version of the RCBHT.
引用
收藏
页数:7
相关论文
共 50 条
[21]   PORTABLE AUTOMATED, INEXPENSIVE MASS AND BALANCE CALIBRATION SYSTEM. [J].
Maxwell III, S.L. ;
Clark, J.P. .
Nuclear materials management, 1987, 16 :670-677
[22]   Transducer Calibration Supported by a Computer and a Data Bank System. [J].
Happe, A. ;
Krull, O. .
TM. Technisches Messen, 1985, 52 (12) :453-458
[23]   Integrated calibration of magnetic gradient tensor system [J].
Yin, Gang ;
Zhang, Yingtang ;
Fan, Hongbo ;
Guo, Quan Ren ;
Li, Zhining .
Journal of Magnetism and Magnetic Materials, 2015, 374 (01) :289-297
[24]   Integrated calibration of magnetic gradient tensor system [J].
Gang, Yin ;
Yingtang, Zhang ;
Hongbo, Fan ;
GuoQuan, Ren ;
Zhining, Li .
Journal of Magnetism and Magnetic Materials, 2015, 374 (0C) :289-297
[25]   Integrated calibration of magnetic gradient tensor system [J].
Yin Gang ;
Zhang Yingtang ;
Fan Hongbo ;
Ren GuoQuan ;
Li Zhining .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2015, 374 :289-297
[26]   Integrated calibration of magnetic gradient tensor system [J].
Gang, Yin ;
Yingtang, Zhang ;
Hongbo, Fan ;
Guoquan, Ren ;
Zhining, Li .
Journal of Magnetism and Magnetic Materials, 2015, 374 :289-297
[27]   Developing a self-applicable verification system. Theory and practice [J].
Kondratyev D.A. ;
Promsky A.V. .
Automatic Control and Computer Sciences, 2015, 49 (07) :445-452
[28]   Enhanced fluid delivery verification on the VITROS ECi immunodiagnostic system. [J].
Van Brunt, N ;
Contestable, P ;
Jacobs, M ;
Potter, R ;
Raymond, M ;
Simon, M .
CLINICAL CHEMISTRY, 2001, 47 (06) :A85-A86
[29]   The uBVI photometric system.: I.: Motivation, implementation, and calibration [J].
Bond, HE .
ASTRONOMICAL JOURNAL, 2005, 129 (06) :2914-2923
[30]   INDEPENDENT VERIFICATION OF THE SENTINEL-1A SYSTEM CALIBRATION [J].
Schwerdt, M. ;
Schmidt, K. ;
Ramon, N. Tous ;
Alfonzo, G. Castellanos ;
Doering, B. ;
Zink, M. ;
Prats, P. .
2014 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2014, :1097-1100