The relationship between the Young's modulus of the stratum corneum and age: a pilot study

被引:46
作者
Hara, Yusuke [1 ]
Masuda, Yuji [1 ]
Hirao, Tetsuji [1 ]
Yoshikawa, Nobuhiro [2 ]
机构
[1] Shiseido Res Ctr, Yokohama, Kanagawa 2248558, Japan
[2] Univ Tokyo, Inst Ind Sci, Tokyo, Japan
关键词
age; Cutometer((R)); Dermal Torque Meter((R)); stratum corneum; Young's modulus; NOVA DPM 9003; SKICON; 200; CM; 825; SKIN; THICKNESS;
D O I
10.1111/srt.12054
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background/purpose: The mechanical properties of the stratum corneum play an important role in protecting the body from external physical stimuli and excessive sensitivity. However, it is difficult to analyze these mechanical properties in vivo. To resolve this problem, we carried out a numerical analysis to calculate the Young's modulus of the stratum corneum. We then investigated the relationship between the Young's modulus of the stratum corneum and age. Methods: We used a Cutometer (R) and a Dermal Torque Meter (R) for measuring skin mechanical parameters, and optical coherence tomography and an ultrasonic imaging system for measuring skin thickness. Based on these non-invasive results, liner elastic analysis was performed by the finite element method, and the Young's moduli of the stratum corneum and the dermis were calculated by solving an inverse problem. Using these techniques, we analyzed the correlation between the Young's modulus of the stratum corneum for the cheeks of seventy-eight Japanese women aged from 20 to 68 years. Results: In the group study, the mean Young's moduli of the stratum corneum and dermis were calculated 1.993 MPa and 0.066 MPa, respectively. While carrying out individual analyses, there was a weak relationship between the Young's modulus of the stratum corneum and age (r = 0.337). Conclusion: We calculated the Young's modulus of the stratum corneum in vivo, with commercially available systems, and found that it is a weak correlation with age in this group of subjects. Future developments of our method would be beneficial in the characterization of facial skin aging and the validation of cosmetic and medical applications.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 23 条
[1]  
AGACHE PG, 1995, HDB NONINVASIVE METH, P319
[2]  
Barel AO., 1995, HDB NONINVASIVE METH, P335
[3]   Comparison of the depth profiles of water and water-binding substances in the stratum corneum determined in vivo by Raman spectroscopy between the cheek and volar forearm skin:: effects of age, seasonal changes and artificial forced hydration [J].
Egawa, M. ;
Tagami, H. .
BRITISH JOURNAL OF DERMATOLOGY, 2008, 158 (02) :251-260
[4]   Effect of exposure of human skin to a dry environment [J].
Egawa, M ;
Oguri, M ;
Kuwahara, T ;
Takahashi, M .
SKIN RESEARCH AND TECHNOLOGY, 2002, 8 (04) :212-218
[5]   In vivo estimation of stratum corneum thickness from water concentration profiles obtained with Raman spectroscopy [J].
Egawa, Mariko ;
Hirao, Tetsuji ;
Takahashi, Motoji .
ACTA DERMATO-VENEREOLOGICA, 2007, 87 (01) :4-8
[6]   Intrinsic aging vs. photoaging: a comparative histopathological, immunohistochemical, and ultrastructural study of skin [J].
El-Domyati, M ;
Attia, S ;
Saleh, F ;
Brown, D ;
Birk, DE ;
Gasparro, F ;
Ahmad, H ;
Uitto, J .
EXPERIMENTAL DERMATOLOGY, 2002, 11 (05) :398-405
[7]   Stratum corneum defensive functions: An integrated view [J].
Elias, PM .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2005, 125 (02) :183-200
[8]   AGE-RELATED MECHANICAL-PROPERTIES OF HUMAN-SKIN - AN INVIVO STUDY [J].
ESCOFFIER, C ;
DERIGAL, J ;
ROCHEFORT, A ;
VASSELET, R ;
LEVEQUE, JL ;
AGACHE, PG .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1989, 93 (03) :353-357
[9]   Comparative study of five instruments measuring stratum corneurn hydration (Comeometer CM 820 and CM 825, Skicon 200, Nova DPM 9003, DermaLab). Part I. In vitro [J].
Fluhr, Joachim W. ;
Gloor, Max ;
Lazzerini, Sabrina ;
Kleesz, Peter ;
Grieshaber, Romano ;
Berardesca, Enzo .
SKIN RESEARCH AND TECHNOLOGY, 1999, 5 (03) :161-170
[10]   Comparative study of five instruments measuring stratum corneum hydration (Corneometer CM 820 and CM 825, Skicon 200, Nova DPM 9003, DermaLab). Part II. In vivo [J].
Fluhr, Joachim W. ;
Gloor, Max ;
Lazzerini, Sabrina ;
Kleesz, Peter ;
Grieshaber, Romano ;
Berardesca, Enzo .
SKIN RESEARCH AND TECHNOLOGY, 1999, 5 (03) :171-178