A comparison of air displacement plethysmography with three other techniques to determine body fat in healthy adults

被引:86
|
作者
Levenhagen, DK
Borel, MJ
Welch, DC
Piasecki, JH
Piasecki, DP
Chen, KY
Flakoll, PJ
机构
[1] Vanderbilt Univ, Med Ctr, Dept Surg, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Med Ctr, Dept Biochem, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Dept Med, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Med Ctr, Clin Nutr Res Unit, Nashville, TN 37232 USA
关键词
D O I
10.1177/0148607199023005293
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: This study compared air displacement plethysmography (ADP), which relies on measurements of body density to estimate body fat, with three other techniques that measure body composition: (1) hydrostatic weighing (HW), which also measures body density; (2) bioelectrical impedance (BIA), which determines electrical resistance and total body water to estimate fat-free mass; and (3) dual-energy x-ray absorptiometry (DXA), which measures bone, fat, and fat-free soft tissue masses. Methods: ADP, HW, BIA, and DXA were performed on 20 healthy volunteers (10 males and 10 females). The subjects were within 20% of ideal body weight, 31.1 +/- 1.8 years of age, and 75.4 +/- 2.7 kg with body mass index values of 25.2 +/- 0.9 (kg/m(2)) and percent body fat by ADP ranging from 6.0% to 41.0%. Results: Percent body fat measurements by the four methods were highly correlated (r >.90, p <.0001). Mean body fat as determined by ADP, HW, BIA, and DXA were 23.4% +/- 2.3%, 23.9% +/- 1.8%, 23.1 +/- 1.9%, and 26.4% +/- 2.4%*, respectively (*p <.05 vs ADP). There was a significantly positive slope (+0.23) for the individual differences vs the average of ADP and HW percent body fat, demonstrating a slightly negative difference at lower body fat levels and a slightly positive difference at greater body fat levels. Although the average percent body fat determined by ADP was similar to that by HW for the entire population, there was a significant gender difference with the average body fat measured by ADP being 16% less in males and 7% greater in females than that determined by HW. Conclusions: Body fat measurements using ADP were highly correlated with those using KW, BLA, and DXA across a relatively wide range of body fat levels in healthy adults. These results support the utility of ADP as a relatively new technique in the estimation of percent body fat in healthy adults. However, the error associated with gender and the level of body fat is not negligible and requires further investigation.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 50 条
  • [41] Comparison of a 2D iPad application and 3D body scanner to air displacement plethysmography for measurement of body fat percentage
    Wagner, D. R.
    Castaneda, F.
    Bohman, B.
    Sterr, W.
    JOURNAL OF HUMAN NUTRITION AND DIETETICS, 2019, 32 (06) : 781 - 788
  • [42] Comparison of Various Body Condition Measurements to Air Displacement Plethysmography in Female Collegiate Athletes
    Lawless, Ryan Z.
    Langford, Emily L.
    Eisenman, Michelle L.
    Snarr, Ronald L.
    Ryan, Greg A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06) : 287 - 287
  • [43] A comparison of bioelectrical impedance analysis and air displacement plethysmography to assess body composition in children
    Chen, Fangfang
    Wu, Lijun
    Chen, Yiren
    Wang, Jing
    Liu, Junting
    Huang, Guimin
    Hou, Dongqing
    Liao, Zijun
    Zhang, Ting
    Xie, Xianghui
    Liu, Gongshu
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [44] Comparison of air displacement plethysmography to hydrostatic weighing for estimating total body density in children
    Claros G.
    Hull H.R.
    Fields D.A.
    BMC Pediatrics, 5 (1)
  • [45] Accuracy of Air Displacement Plethysmography Body Composition Measure in Estimating Resting Metabolic Rate in Adults
    Faciana, Chris
    O'Driscoll, Kelsey F.
    McElrath, Laura
    Pence, Stephanie
    Mendel, Ronald W.
    Otterstetter, Ronald
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 796 - 796
  • [46] Body Composition Comparisons Using A Self-Testing Air Displacement Plethysmography Unit In Adults
    King, Jason T.
    Clasey, Jody L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S298 - S298
  • [47] Interaction of clothing and body mass index affects validity of air-displacement plethysmography in adults
    Shafer, Kimberly J.
    Siders, William A.
    Johnson, LuAnn K.
    Lukaski, Henry C.
    NUTRITION, 2008, 24 (02) : 148 - 154
  • [48] Can air-displacement plethysmography replace hydrodensitometry for body composition analysis in children and adults?
    Ellis, KJ
    Pratt, L
    Puyau, M
    Shypailo, R
    Butte, NF
    FASEB JOURNAL, 2001, 15 (05) : A1004 - A1004
  • [49] Body-composition assessment via air-displacement plethysmography in adults and children: a review
    Fields, DA
    Goran, MI
    McCrory, MA
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2002, 75 (03) : 453 - 467
  • [50] Comparison of body adiposity index (BAI) and air displacement plethysmograph with estimations of % body fat in adults with Down’s syndrome
    M Rossato
    R A Dellagrana
    E de Souza Bezerra
    R M da Costa
    J O L dos Santos
    D A S Silva
    F Diefenthaeler
    European Journal of Clinical Nutrition, 2017, 71 : 1341 - 1344