A comparison of air displacement plethysmography with three other techniques to determine body fat in healthy adults

被引:86
|
作者
Levenhagen, DK
Borel, MJ
Welch, DC
Piasecki, JH
Piasecki, DP
Chen, KY
Flakoll, PJ
机构
[1] Vanderbilt Univ, Med Ctr, Dept Surg, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Med Ctr, Dept Biochem, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Dept Med, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Med Ctr, Clin Nutr Res Unit, Nashville, TN 37232 USA
关键词
D O I
10.1177/0148607199023005293
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: This study compared air displacement plethysmography (ADP), which relies on measurements of body density to estimate body fat, with three other techniques that measure body composition: (1) hydrostatic weighing (HW), which also measures body density; (2) bioelectrical impedance (BIA), which determines electrical resistance and total body water to estimate fat-free mass; and (3) dual-energy x-ray absorptiometry (DXA), which measures bone, fat, and fat-free soft tissue masses. Methods: ADP, HW, BIA, and DXA were performed on 20 healthy volunteers (10 males and 10 females). The subjects were within 20% of ideal body weight, 31.1 +/- 1.8 years of age, and 75.4 +/- 2.7 kg with body mass index values of 25.2 +/- 0.9 (kg/m(2)) and percent body fat by ADP ranging from 6.0% to 41.0%. Results: Percent body fat measurements by the four methods were highly correlated (r >.90, p <.0001). Mean body fat as determined by ADP, HW, BIA, and DXA were 23.4% +/- 2.3%, 23.9% +/- 1.8%, 23.1 +/- 1.9%, and 26.4% +/- 2.4%*, respectively (*p <.05 vs ADP). There was a significantly positive slope (+0.23) for the individual differences vs the average of ADP and HW percent body fat, demonstrating a slightly negative difference at lower body fat levels and a slightly positive difference at greater body fat levels. Although the average percent body fat determined by ADP was similar to that by HW for the entire population, there was a significant gender difference with the average body fat measured by ADP being 16% less in males and 7% greater in females than that determined by HW. Conclusions: Body fat measurements using ADP were highly correlated with those using KW, BLA, and DXA across a relatively wide range of body fat levels in healthy adults. These results support the utility of ADP as a relatively new technique in the estimation of percent body fat in healthy adults. However, the error associated with gender and the level of body fat is not negligible and requires further investigation.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 50 条
  • [31] Air Displacement Plethysmography Versus Bioelectrical Impedance to Determine Body Composition in Pediatric Hemodialysis Patients
    Vega, Molly Wong
    Srivaths, Poyyapakkam R.
    JOURNAL OF RENAL NUTRITION, 2017, 27 (06) : 439 - 444
  • [32] Comparison of Body Composition Measurement With Whole Body Multifrequency Bioelectrical Impedance and Air Displacement Plethysmography in Healthy Middle-Aged Women
    Benton, Melissa J.
    Swan, Pamela D.
    Schlairet, Maura C.
    Sanderson, Sonya
    HEALTH CARE FOR WOMEN INTERNATIONAL, 2011, 32 (12) : 1068 - 1078
  • [33] Body Composition Analysis by Air Displacement Plethysmography in Normal Weight to Extremely Obese Adults
    Hames, Kazanna C.
    Anthony, Steven J.
    Thornton, John C.
    Gallagher, Dympna
    Goodpaster, Bret H.
    OBESITY, 2014, 22 (04) : 1078 - 1084
  • [34] Hand-to-foot bioelectrical impedance analysis to measure fat mass in healthy children: A comparison with air-displacement plethysmography
    Foucart, Lisa
    De Decker, Annelies
    Sioen, Isabelle
    De Henauw, Stefaan
    Michels, Nathalie
    NUTRITION & DIETETICS, 2017, 74 (05) : 516 - 520
  • [35] Validation of air-displacement plethysmography to measure body fat - Reply to JS']JS Garrow
    McCrory, MA
    Goran, MI
    Fields, DA
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2003, 77 (05): : 1339 - 1340
  • [36] Effect of body hair on air-displacement plethysmography
    Potter, C
    King, GA
    Thompson, DL
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S72 - S72
  • [37] A Comparison Of Body Fat Percentage Estimates Between Dual-energy X-ray Absorptiometry And Air Displacement Plethysmography
    Nowak, Kathryn M.
    Kaminsky, Leonard A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S299 - S300
  • [38] Validation of air displacement plethysmography for assessing body composition
    Wagner, DR
    Heyward, VH
    Gibson, AL
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (07): : 1339 - 1344
  • [39] Comparison of a 2D iPad application and 3D body scanner to air displacement plethysmography for measurement of body fat percentage
    Wagner, D. R.
    Castaneda, F.
    Bohman, B.
    Sterr, W.
    JOURNAL OF HUMAN NUTRITION AND DIETETICS, 2019, 32 (06) : 781 - 788
  • [40] COMPARISON OF BODY FAT ESTIMATION USING SKIN FOLD THICKNESS MEASUREMENT AND SIMULTANEOUS AIR-DISPLACEMENT PLETHYSMOGRAPHY AT 8 WEEKS
    Liu, N. Hou
    Hourihane, J. O.
    Kenny, L.
    Kiely, M.
    Irvine, A. D.
    Murray, D. M.
    PEDIATRIC RESEARCH, 2010, 68 : 208 - 208