Strategies for monitoring the emerging polar organic contaminants in water with emphasis on integrative passive sampling

被引:65
作者
Soderstrom, Hanna [1 ]
Lindberg, Richard H. [1 ]
Fick, Jerker [1 ]
机构
[1] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
关键词
Environmental monitoring; Water analysis; Passive sampling; Time-integrative sampling; Polar organic contaminants; Emerging contaminants; Pharmaceuticals; SEMIPERMEABLE-MEMBRANE DEVICES; SEWAGE-TREATMENT PLANTS; PERSONAL-CARE PRODUCTS; AQUATIC ENVIRONMENTS; WASTE-WATER; ANTIBIOTIC SUBSTANCES; MASS-SPECTROMETRY; RIVER WATER; CAGED FISH; IN-SITU;
D O I
10.1016/j.chroma.2008.08.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although polar organic contaminants (POCs) Such as pharmaceuticals are considered as some of today's most emerging contaminants few of them are regulated or included in on-going monitoring programs. However, the growing concern among the public and researchers together with the new legislature within the European Union, the registration, evaluation and authorisation of chemicals (REACH) system will increase the future need of simple, low cost strategies for monitoring and risk assessment of POCs in aquatic environments. In this article, we overview the advantages and shortcomings of traditional and novel sampling techniques available for monitoring the emerging POCs in water. The benefits and drawbacks of using active and biological sampling were discussed and the principles of organic passive samplers (PS) presented. A detailed overview of type of polar organic PS available, and their classes of target compounds and Held of applications were given, and the considerations involved in using them such as environmental effects and quality control were discussed. The usefulness of biological sampling of POCs in water was found to be limited. Polar organic PS was considered to be the only available, but nevertheless, an efficient alternative to active water sampling due to its simplicity, low cost, no need of power supply or maintenance, and the ability of collecting time-integrative samples with one sample collection. However, the polar organic PS need to be further developed before they can be used as standard in water quality monitoring programs. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:623 / 630
页数:8
相关论文
共 50 条
  • [31] Optimization of the polar organic chemical integrative sampler for the sampling of acidic and polar herbicides
    Fauvelle, Vincent
    Mazzella, Nicolas
    Belles, Angel
    Moreira, Aurelie
    Allan, Ian J.
    Budzinski, Helene
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (13) : 3191 - 3199
  • [32] Monitoring for contaminants of emerging concern in drinking water using POCIS passive samplers
    Metcalfe, Chris
    Hoque, M. Ehsanul
    Sultana, Tamanna
    Murray, Craig
    Helm, Paul
    Kleywegt, Sonya
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2014, 16 (03) : 473 - 481
  • [33] In situ calibration of polar organic chemical integrative sampler (POCIS) for monitoring of pharmaceuticals in surface waters
    Vrana, Branislav
    Urik, Jakub
    Fedorova, Ganna
    Svecova, Helena
    Grabicova, Katerina
    Golovko, Oksana
    Randak, Tomas
    Grabic, Roman
    ENVIRONMENTAL POLLUTION, 2021, 269 (269)
  • [34] Use of Mixed-Mode Ion Exchange Sorbent for the Passive Sampling of Organic Acids by Polar Organic Chemical Integrative Sampler (POCIS)
    Fauvelle, Vincent
    Mazzella, Nicolas
    Delmas, Francois
    Madarassou, Karine
    Eon, Melissa
    Budzinski, Helene
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (24) : 13344 - 13353
  • [35] A new configuration of polar organic chemical integrative sampler with nylon membranes to monitor emerging organophosphate ester contaminants in urban surface water
    Xiong, Jingjing
    Li, Huizhen
    Ma, Xue
    Tan, Baoxiang
    You, Jing
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2020, 202
  • [36] Estimating pesticide sampling rates by the polar organic chemical integrative sampler (POCIS) in the presence of natural organic matter and varying hydrodynamic conditions
    Charlestra, Lucner
    Amirbahman, Aria
    Courtemanch, David L.
    Alvarez, David A.
    Patterson, Howard
    ENVIRONMENTAL POLLUTION, 2012, 169 : 98 - 104
  • [37] Evaluation of ceramic passive samplers using a mixed-mode strong cation-exchange sorbent to monitor polar contaminants in river water
    Cliville-Cabre, Pol
    Lacorte, Silvia
    Borrull, Francesc
    Fontanals, Nuria
    Marce, Rosa Maria
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1708
  • [38] Control of organic contaminants in groundwater by passive sampling and multivariate statistical analysis
    Korosa, A.
    Mali, N.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 318
  • [39] Aquatic passive sampling of perfluorinated chemicals with polar organic chemical integrative sampler and environmental factors affecting sampling rate
    Li, Ying
    Yang, Cunman
    Bao, Yijun
    Ma, Xueru
    Lu, Guanghua
    Li, Yi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (16) : 16096 - 16103
  • [40] Passive sampling techniques for monitoring pollutants in water
    Vrana, B
    Mills, GA
    Allan, IJ
    Dominiak, E
    Svensson, K
    Knutsson, J
    Morrison, G
    Greenwood, R
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (10) : 845 - 868