Strategies for monitoring the emerging polar organic contaminants in water with emphasis on integrative passive sampling

被引:65
作者
Soderstrom, Hanna [1 ]
Lindberg, Richard H. [1 ]
Fick, Jerker [1 ]
机构
[1] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
关键词
Environmental monitoring; Water analysis; Passive sampling; Time-integrative sampling; Polar organic contaminants; Emerging contaminants; Pharmaceuticals; SEMIPERMEABLE-MEMBRANE DEVICES; SEWAGE-TREATMENT PLANTS; PERSONAL-CARE PRODUCTS; AQUATIC ENVIRONMENTS; WASTE-WATER; ANTIBIOTIC SUBSTANCES; MASS-SPECTROMETRY; RIVER WATER; CAGED FISH; IN-SITU;
D O I
10.1016/j.chroma.2008.08.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although polar organic contaminants (POCs) Such as pharmaceuticals are considered as some of today's most emerging contaminants few of them are regulated or included in on-going monitoring programs. However, the growing concern among the public and researchers together with the new legislature within the European Union, the registration, evaluation and authorisation of chemicals (REACH) system will increase the future need of simple, low cost strategies for monitoring and risk assessment of POCs in aquatic environments. In this article, we overview the advantages and shortcomings of traditional and novel sampling techniques available for monitoring the emerging POCs in water. The benefits and drawbacks of using active and biological sampling were discussed and the principles of organic passive samplers (PS) presented. A detailed overview of type of polar organic PS available, and their classes of target compounds and Held of applications were given, and the considerations involved in using them such as environmental effects and quality control were discussed. The usefulness of biological sampling of POCs in water was found to be limited. Polar organic PS was considered to be the only available, but nevertheless, an efficient alternative to active water sampling due to its simplicity, low cost, no need of power supply or maintenance, and the ability of collecting time-integrative samples with one sample collection. However, the polar organic PS need to be further developed before they can be used as standard in water quality monitoring programs. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:623 / 630
页数:8
相关论文
共 47 条
[11]   Environmental exposure assessment of fluoroquinolone antibacterial agents from sewage to soil [J].
Golet, EM ;
Xifra, I ;
Siegrist, H ;
Alder, AC ;
Giger, W .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (15) :3243-3249
[12]  
Greenwood R., 2006, TRENDS ANAL CHEM, V25, P751
[13]   Occurrence, fate and effects of pharmaceutical substances in the environment - A review [J].
Halling-Sorensen, B ;
Nielsen, SN ;
Lanzky, PF ;
Ingerslev, F ;
Lutzhoft, HCH ;
Jorgensen, SE .
CHEMOSPHERE, 1998, 36 (02) :357-394
[14]  
Heberer T, 1998, ACTA HYDROCH HYDROB, V26, P272, DOI 10.1002/(SICI)1521-401X(199809)26:5<272::AID-AHEH272>3.0.CO
[15]  
2-O
[16]   Occurrence of antibiotics in the aquatic environment [J].
Hirsch, R ;
Ternes, T ;
Haberer, K ;
Kratz, KL .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 225 (1-2) :109-118
[17]   SEMIPERMEABLE-MEMBRANE DEVICES CONTAINING MODEL LIPID - A NEW APPROACH TO MONITORING THE BIOAVAILABILITY OF LIPOPHILIC CONTAMINANTS AND ESTIMATING THEIR BIOCONCENTRATION POTENTIAL [J].
HUCKINS, JN ;
TUBERGEN, MW ;
MANUWEERA, GK .
CHEMOSPHERE, 1990, 20 (05) :533-552
[18]   Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices [J].
Huckins, JN ;
Petty, JD ;
Lebo, JA ;
Almeida, FV ;
Booij, K ;
Alvarez, DA ;
Clark, RC ;
Mogensen, BB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (01) :85-91
[19]   Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water [J].
Huckins, JN ;
Petty, JD ;
Orazio, CE ;
Lebo, JA ;
Clark, RC ;
Gibson, VL ;
Gala, WR ;
Echols, KR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (21) :3918-3923
[20]   LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANIC CONTAMINANTS IN WATER [J].
HUCKINS, JN ;
MANUWEERA, GK ;
PETTY, JD ;
MACKAY, D ;
LEBO, JA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) :2489-2496