Monte Carlo model of the scanning beam digital x-ray (SBDX) source

被引:6
作者
Bazalova, M. [1 ]
Weil, M. D. [2 ]
Wilfley, B. [3 ]
Graves, E. E. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Sirius Med LLC, Half Moon Bay, CA 94019 USA
[3] Triple Ring Technol, Newark, CA 94560 USA
关键词
SKIN INJURIES; RADIATION; TOMOSYNTHESIS; SIMULATIONS; EFFICIENCY; EXPOSURE;
D O I
10.1088/0031-9155/57/22/7381
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The scanning-beam digital x-ray (SBDX) system has been developed for fluoroscopic imaging using an inverse x-ray imaging geometry. The SBDX system consists of a large-area x-ray source with a multihole collimator and a small detector. The goal of this study was to build a Monte Carlo (MC) model of the SBDX source as a useful tool for optimization of the SBDX imaging system in terms of its hardware components and imaging parameters. The MC model of the source was built in the EGSnrc/BEAMnrc code and validated using the DOSXYZnrc code and Gafchromic film measurements for 80, 100, and 120 kV x-ray source voltages. The MC simulated depth dose curves agreed with measurements to within 5%, and beam profiles at three selected depths generally agreed within 5%. Exposure rates and half-value layers for three voltages were also calculated from the MC simulations. Patient skin-dose per unit detector-dose was quantified as a function of patient size for all three x-ray source voltages. The skin-dose to detector-dose ratio ranged from 5-10 for a 20 cm thick patient to 1 x 10(3)-1 x 10(5) for a 50 cm patient for the 120 and 80 kV beams, respectively. Simulations of imaging dose for a prostate patient using common imaging parameters revealed that skin-dose per frame was as low as 0.2 mGy.
引用
收藏
页码:7381 / 7394
页数:14
相关论文
共 50 条
[31]   Monte Carlo simulations for 20 MV X-ray spectrum reconstruction of a linear induction accelerator [J].
Wang Yi ;
Li Qin ;
Jiang Xiao-Guo .
CHINESE PHYSICS C, 2012, 36 (09) :861-866
[32]   Monte Carlo Semi-Empirical Model for Si(Li) X-Ray Detector: Differences between Nominal and Fitted Parameters [J].
Lopez-Pino, N. ;
Padilla-Cabal, F. ;
Garcia-Alvarez, J. A. ;
Vazquez, L. ;
D' Alessandro, K. ;
Correa-Alfonso, C. M. ;
Godoy, W. ;
Maidana, N. L. ;
Vanin, V. R. .
XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 :134-136
[33]   The influence of breast skin thickness variation with aging on the mammographic X-ray spectra: A Monte Carlo study [J].
Zadehrafi, M. .
INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (04) :971-978
[34]   Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens [J].
Freed, Melanie ;
Miller, Stuart ;
Tang, Katherine ;
Badano, Aldo .
MEDICAL PHYSICS, 2009, 36 (11) :4944-4956
[35]   Quantitative Elemental Microanalysis Of Individual Particles With Use Of X-Ray Fluorescence Method And Monte Carlo Simulation [J].
Czyzycki, Mateusz ;
Lankosz, Marek ;
Bielewski, Marek .
X-RAY OPTICS AND MICROANALYSIS, PROCEEDINGS, 2010, 1221 :98-100
[36]   Validation of the Geant4 Monte Carlo package for X-ray fluorescence spectroscopy in triaxial geometry [J].
Amaro, Pedro ;
Santos, Jose Paulo ;
Samouco, Ana ;
Adao, Ricardo ;
Martins, Luis Souto ;
Weber, Sebastian ;
Tashenov, Stanislav ;
Carvalho, Maria Luisa ;
Pessanha, Sofia .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 :60-66
[37]   Dosimetric validation of SmART-RAD Monte Carlo modelling for x-ray cabinet radiobiology irradiators [J].
Hill, Mark A. ;
Staut, Nick ;
Thompson, James M. ;
Verhaegen, Frank .
PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (09)
[38]   X-ray fluorescence spectroscopy and Monte Carlo simulation for quantitative characterization of Bolivianpre-Hispanicgolden artefacts [J].
Melquiades, Fabio L. ;
Santos, Sandro V. ;
Lopes, Fabio ;
Villanueva, Juan ;
Ticona, Jorge L. ;
Appoloni, Carlos R. .
X-RAY SPECTROMETRY, 2021, 50 (01) :53-67
[39]   Spectrum formation in X-ray pulsars at very low mass accretion rate: Monte Carlo approach [J].
Mushtukov, Alexander A. ;
Suleimanov, Valery F. ;
Tsygankov, Sergey S. ;
Zwart, Simon Portegies .
MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2021, 503 (04) :5193-5203
[40]   Monte Carlo calculated kilovoltage x-ray arc therapy plans for three lung cancer patients [J].
Breitkreutz, Dylan Yamabe ;
Renaud, Marc-Andre ;
Weil, Michael David ;
Zavgorodni, Sergei ;
Han, Jaeyoung ;
Baxter, Henry ;
Seuntjens, Jan ;
Song, Samuel ;
Boyd, Douglas ;
Bazalova-Carter, Magdalena .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (06)