Monte Carlo model of the scanning beam digital x-ray (SBDX) source

被引:6
|
作者
Bazalova, M. [1 ]
Weil, M. D. [2 ]
Wilfley, B. [3 ]
Graves, E. E. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Sirius Med LLC, Half Moon Bay, CA 94019 USA
[3] Triple Ring Technol, Newark, CA 94560 USA
关键词
SKIN INJURIES; RADIATION; TOMOSYNTHESIS; SIMULATIONS; EFFICIENCY; EXPOSURE;
D O I
10.1088/0031-9155/57/22/7381
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The scanning-beam digital x-ray (SBDX) system has been developed for fluoroscopic imaging using an inverse x-ray imaging geometry. The SBDX system consists of a large-area x-ray source with a multihole collimator and a small detector. The goal of this study was to build a Monte Carlo (MC) model of the SBDX source as a useful tool for optimization of the SBDX imaging system in terms of its hardware components and imaging parameters. The MC model of the source was built in the EGSnrc/BEAMnrc code and validated using the DOSXYZnrc code and Gafchromic film measurements for 80, 100, and 120 kV x-ray source voltages. The MC simulated depth dose curves agreed with measurements to within 5%, and beam profiles at three selected depths generally agreed within 5%. Exposure rates and half-value layers for three voltages were also calculated from the MC simulations. Patient skin-dose per unit detector-dose was quantified as a function of patient size for all three x-ray source voltages. The skin-dose to detector-dose ratio ranged from 5-10 for a 20 cm thick patient to 1 x 10(3)-1 x 10(5) for a 50 cm patient for the 120 and 80 kV beams, respectively. Simulations of imaging dose for a prostate patient using common imaging parameters revealed that skin-dose per frame was as low as 0.2 mGy.
引用
收藏
页码:7381 / 7394
页数:14
相关论文
共 50 条
  • [1] Investigation of tomosynthetic perfusion measurements using the scanning-beam digital x-ray (SBDX) system
    Nett, B
    Chen, GH
    Van Lysel, M
    Betts, T
    Speidel, M
    Rowley, H
    Kienitz, BA
    Mistretta, CA
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 89 - 100
  • [2] Monte Carlo dosimetry of a cell culture irradiation model using a 6 MV X-ray beam
    Hernandez-Bojorquez, Mariana
    Trejo-Solis, Cristina
    Manuel Larraga-Gutierrez, Jose
    Martinez-Davalos, Arnulfo
    RADIATION PHYSICS AND CHEMISTRY, 2021, 180
  • [3] Towards standardization of x-ray beam filters in digital mammography and digital breast tomosynthesis: Monte Carlo simulations and analytical modelling
    Shrestha, Suman
    Vedantham, Srinivasan
    Karellas, Andrew
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05) : 1969 - 1993
  • [4] Optimization of x-ray spectra in digital mammography through Monte Carlo simulations
    Cunha, D. M.
    Tomal, A.
    Poletti, M. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07) : 1919 - 1935
  • [5] Monte Carlo simulation of x-ray scatter based on patient model from digital breast tomosynthesis
    Liu, Bob
    Wu, Tao
    Moore, Richard H.
    Kopans, Daniel B.
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [6] Monte Carlo simulation of an x-ray volume imaging cone beam CT unit
    Spezi, Emiliano
    Downes, Patrick
    Radu, Emil
    Jarvis, Richard
    MEDICAL PHYSICS, 2009, 36 (01) : 127 - 136
  • [7] Monte-Carlo dosimetry for intraoperative radiotherapy using a low energy x-ray source
    Bouzid, Dounia
    Bert, Julien
    Dupre, Pierre-Francois
    Benhalouche, Saadia
    Pradier, Olivier
    Boussion, Nicolas
    Visvikis, Dimitris
    ACTA ONCOLOGICA, 2015, 54 (10) : 1788 - 1795
  • [8] Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs
    Nelson, Geoff
    Yoon, Sungwon
    Krishna, Ganesh
    Wilfley, Brian
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2013, 40 (11)
  • [9] X-ray radiography of HPGe detectors for Monte Carlo simulations
    Pohuliai, Serhii
    Vlasenko, Andrey
    Malgin, Vladislav
    Kanapelka, Marina
    APPLIED RADIATION AND ISOTOPES, 2023, 198
  • [10] Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: A Monte Carlo study
    Manohar, Nivedh
    Jones, Bernard L.
    Cho, Sang Hyun
    MEDICAL PHYSICS, 2014, 41 (10)