Monte Carlo model of the scanning beam digital x-ray (SBDX) source

被引:6
作者
Bazalova, M. [1 ]
Weil, M. D. [2 ]
Wilfley, B. [3 ]
Graves, E. E. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Sirius Med LLC, Half Moon Bay, CA 94019 USA
[3] Triple Ring Technol, Newark, CA 94560 USA
关键词
SKIN INJURIES; RADIATION; TOMOSYNTHESIS; SIMULATIONS; EFFICIENCY; EXPOSURE;
D O I
10.1088/0031-9155/57/22/7381
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The scanning-beam digital x-ray (SBDX) system has been developed for fluoroscopic imaging using an inverse x-ray imaging geometry. The SBDX system consists of a large-area x-ray source with a multihole collimator and a small detector. The goal of this study was to build a Monte Carlo (MC) model of the SBDX source as a useful tool for optimization of the SBDX imaging system in terms of its hardware components and imaging parameters. The MC model of the source was built in the EGSnrc/BEAMnrc code and validated using the DOSXYZnrc code and Gafchromic film measurements for 80, 100, and 120 kV x-ray source voltages. The MC simulated depth dose curves agreed with measurements to within 5%, and beam profiles at three selected depths generally agreed within 5%. Exposure rates and half-value layers for three voltages were also calculated from the MC simulations. Patient skin-dose per unit detector-dose was quantified as a function of patient size for all three x-ray source voltages. The skin-dose to detector-dose ratio ranged from 5-10 for a 20 cm thick patient to 1 x 10(3)-1 x 10(5) for a 50 cm patient for the 120 and 80 kV beams, respectively. Simulations of imaging dose for a prostate patient using common imaging parameters revealed that skin-dose per frame was as low as 0.2 mGy.
引用
收藏
页码:7381 / 7394
页数:14
相关论文
共 20 条
[1]   Efficiency improvements of x-ray simulations in EGSnrc user-codes using bremsstrahlung cross-section enhancement (BCSE) [J].
Ali, E. S. M. ;
Rogers, D. W. O. .
MEDICAL PHYSICS, 2007, 34 (06) :2143-2154
[2]   Monte Carlo Simulations of a Novel Kilovoltage Radiotherapy Source [J].
Bazalova, M. ;
Weil, M. ;
Graves, E. .
MEDICAL PHYSICS, 2011, 38 (06) :3767-+
[3]   The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy [J].
Bazalova, Magdalena ;
Graves, Edward E. .
MEDICAL PHYSICS, 2011, 38 (06) :3039-3049
[4]  
Berger M J., 1999, XCOM: photon cross sections database
[5]  
Bushberg JT, 2001, ESSENTIAL PHYS MED I
[6]   Fast tomosynthesis for lung cancer detection using the SBDX geometry [J].
Fahrig, R ;
Pineda, AR ;
Solomon, EG ;
Leung, AN ;
Pejc, NJ .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :371-378
[8]  
Hubbell JH., 1996, 5632 NIST ION RAD DI
[9]   Skin injuries from fluoroscopically guided procedures: part I, Characteristics of radiation injury [J].
Koenig, TR ;
Wolff, D ;
Mettler, FA ;
Wagner, LK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (01) :3-11
[10]   The AAPM/RSNA physics tutorial for residents - Fluoroscopy: Patient radiation exposure issues [J].
Mahesh, M .
RADIOGRAPHICS, 2001, 21 (04) :1033-1045