Accuracy of full guided vs. half-guided implant surgery

被引:81
作者
Kuehl, S. [1 ]
Zuercher, S. [1 ]
Mahid, T. [2 ]
Mueller-Gerbl, M. [3 ]
Filippi, A. [1 ]
Cattin, P. [2 ]
机构
[1] Univ Basel, Sch Dent Med, Dept Oral Surg Oral Radiol & Oral Med, CH-4056 Basel, Switzerland
[2] Univ Basel, Univ Basel Hosp, Med Image Anal Ctr, CH-4056 Basel, Switzerland
[3] Univ Basel, Inst Anat, CH-4056 Basel, Switzerland
关键词
dental implants; guidance; templates; SURGICAL GUIDES; DENTISTRY; SYSTEMS; TECHNOLOGY; PLACEMENT;
D O I
10.1111/j.1600-0501.2012.02484.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The benefit in terms of higher accuracy for full guided implant surgery (template based guided cavity preparation and guided implant insertion) compared with half-guided surgery (template based guided cavity preparation and free-handed, manual implant insertion) has not been proved till now. Material and methods A total of 38 identical implants were inserted into five human cadaver jaws, after virtual implant planning with the coDiagnostiX device. All cavities were drilled using templates equipped with tubes for guidance. At random, 19 implants were inserted in a free handed way (half-guided), whereas 19 implants were inserted in a guided way through the templates tubes (full guided). Postoperative cone beam computer tomographies (CBCT) were performed, and based on image fusion the total deviations between the virtual implant positions at the implants base and tip were determined and compared between both implantation modi. Results The mean difference in accuracy between both implantation modalities at the implants bases was 0.72mm (range: 0.16-1.17mm, SD: 0.45). The mean difference in accuracy between both modalities at the implants tips was 0.46mm (range: 0.16-1.23mm. SD: 0.49). Although full guided implantation showed a generally higher accuracy (mean tip: 1.54mm, range: 0.33-3.64mm; mean base: 1.52mm, range: 0.4-3.54mm) than half-guided implantation (mean tip: 1.84mm, range: 0.84-3.22mm; mean base: 1.56mm, range: 0.49-3.43mm), the differences were not statistically significant. Conclusions The accuracy of half-guided implant surgery is comparable with full guided implant surgery.
引用
收藏
页码:763 / 769
页数:7
相关论文
共 20 条
[1]   Accuracy of Two Stereolithographic Guide Systems for Computer-Aided Implant Placement: A Computed Tomography-Based Clinical Comparative Study [J].
Arisan, Volkan ;
Karabuda, Z. Cuneyt ;
Ozdemir, Tayfun .
JOURNAL OF PERIODONTOLOGY, 2010, 81 (01) :43-51
[2]   Accuracy and Complications Using Computer-Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature [J].
D'haese, Jan ;
Van De Velde, Tommie ;
Komiyama, Ai ;
Hultin, Margaretha ;
De Bruyn, Hugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (03) :321-335
[3]   Basic research and 12 years of clinical experience in computer-assisted navigation technology: a review [J].
Ewers, R ;
Schicho, K ;
Undt, G ;
Wanschitz, F ;
Truppe, M ;
Seemann, R ;
Wagner, A .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (01) :1-8
[4]  
Fortin T., 2007, INT J ORAL MAXILLOF, V65, P393
[5]  
Hämmerle CHF, 2009, INT J ORAL MAX IMPL, V24, P126
[6]  
Jabero Marvin, 2006, Implant Dent, V15, P135, DOI 10.1097/01.id.0000217790.68814.1e
[7]  
Jolliffe I., 2002, Principal Component Analysis, P78, DOI [DOI 10.1007/0-387-22440-8_5, DOI 10.1007/0-387-22440-85]
[8]  
Jung RE, 2009, INT J ORAL MAX IMPL, V24, P92
[9]   Prosthetically Driven, Computer-Guided Implant Planning for the Edentulous Maxilla: A Model Study [J].
Katsoulis, Joannis ;
Pazera, Pawel ;
Mericske-Stern, Regina .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (03) :238-245
[10]  
Miller Robert J, 2006, Implant Dent, V15, P41, DOI 10.1097/01.id.0000202637.61180.2b