Clinical outcome of the PAS-Port® proximal anastomosis system in off-pump coronary artery bypass grafting in 201 patients

被引:0
作者
Verberkmoes, N. J. [1 ]
Mokhles, M. M. [2 ]
Bramer, S. [1 ]
Van Straten, A. H. M. [1 ]
Ter Woorst, J. F. [1 ]
Maessen, J. G. [3 ]
Berreklouw, E. [1 ]
机构
[1] Catharina Hosp, Dept Cardiothorac Surg, Eindhoven, Netherlands
[2] Erasmus MC, Dept Cardiothorac Surg, Rotterdam, Netherlands
[3] MUMC, Cardiovasc Res Inst Maastricht CARIM, Dept Cardiothorac Surg, Maastricht, Netherlands
关键词
Outcome Assessment (Health Care); Surgical instruments; Coronary artery bypass; off-pump; RANDOMIZED-TRIAL; FOLLOW-UP; SURGERY; DEVICE; PATENCY; DISEASE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim. The PAS-Port (R) Proximal Anastomosis System (Cardica, Inc, Redwood City, CA, USA) has been used worldwide since March 2003. The objective of the present study was to evaluate the clinical outcome of the PAS-Port (R) Proximal Anastomosis System. Methods. All the patients who underwent off-pump coronary artery bypass grafting in the Catharina Hospital Eindhoven between August 2006 and April 2010 were included in a non-randomized retrospective case-control study, if they had at least one proximal vein graft anastomosis. Study end-points consisted of overall survival, coronary reintervention and postoperative stroke. Results. The study included 312 patients (201 cases, 111 controls). After 36 months of follow-up there was no difference in survival between cases and controls (92.2% vs. 93.7%, P=0.52). No significant difference could be detected between cases and controls with respect to overall coronary reintervention-free survival (93% vs. 96.4%, P=0.20) and freedom from coronary reintervention due to proximal vein graft failure (98% vs. 100% P=0.14). The use of the PAS-Port system could not be identified as an independent risk factor of coronary reintervention (p=0.21). Postoperative stroke rates of cases and controls (2% vs. 0.9%, P=0.42) were comparable. Conclusion. The clinical outcomes in patients treated with the PAS-Port (R) Proximal Anastomosis System were satisfactory compared with those treated with the conventional hand-sewing technique. The use of the PAS-Port system was not associated with higher adverse outcome in terms of overall survival, stroke, coronary reintervention-free survival and freedom from reintervention due to proximal vein graft failure.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 50 条
  • [1] Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial)
    Puskas, John D.
    Halkos, Michael E.
    Balkhy, Husam
    Caskey, Michael
    Connolly, Mark
    Crouch, John
    Diegeler, Anno
    Gummert, Jan
    Harringer, Wolfgang
    Subramanian, Valavanur
    Sutter, Francis
    Matschke, Klaus
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (01) : 125 - 132
  • [2] HEARTSTRING enabled no-touch proximal anastomosis for off-pump coronary artery bypass grafting: current evidence and technique
    Emmert, Maximilian Y.
    Gruenenfelder, Juerg
    Scherman, Jacques
    Cocchieri, Riccardo
    van Boven, Wim-Jan P.
    Falk, Volkmar
    Salzberg, Sacha P.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (03) : 538 - 541
  • [3] Novel Surgical Method of Proximal Anastomosis in Off-Pump Coronary Artery Bypass Grafting
    Chen, Xin
    Chen, Xujun
    Shi, Kaihui
    Xu, Ming
    Wang, Liming
    Jiang, Yingshuo
    CIRCULATION JOURNAL, 2009, 73 (07) : 1342 - 1343
  • [4] Off-Pump Versus On-Pump Coronary Artery Bypass Grafting
    Moller, Christian H.
    Steinbruechel, Daniel A.
    CURRENT CARDIOLOGY REPORTS, 2014, 16 (03)
  • [5] Anaortic off-pump versus clampless off-pump using the PAS-Port device versus conventional coronary artery bypass grafting: mid-term results from a matched propensity score analysis of 5422 unselected patients
    Furukawa, Nobuyuki
    Kuss, Oliver
    Preindl, Konstantin
    Renner, Andre
    Aboud, Anas
    Hakim-Meibodi, Kavous
    Benzinger, Michael
    Puehler, Thomas
    Ensminger, Stephan
    Fujita, Buntaro
    Becker, Tobias
    Gummert, Jan F.
    Boergermann, Jochen
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (04) : 760 - 767
  • [6] Long-Term Clinical Outcome of the Symmetry Aortic Connector System in Off-Pump Coronary Artery Bypass Grafting
    Verberkmoes, Niels J.
    Mokhles, M. Mostafa
    Bramer, Sander
    van Straten, Albert H. M.
    ter Woorst, Joost F.
    Maessen, Jos G.
    Berreklouw, Eric
    THORACIC AND CARDIOVASCULAR SURGEON, 2013, 61 (08) : 669 - 675
  • [7] Off-Pump Coronary Artery Bypass Grafting is Overutilized
    Razavi, Allen A.
    Malas, Jad
    Salam, Aminah
    Emerson, Dominic A.
    Bowdish, Michael E.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2025, 37 (01) : 43 - 47
  • [8] Early angiographic evaluation after off-pump coronary artery bypass grafting
    Nakano, Jota
    Okabayashi, Hitoshi
    Noma, Hisashi
    Sato, Tosiya
    Sakata, Ryuzo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (05) : 1119 - 1125
  • [9] CONVERSIONS IN OFF-PUMP CORONARY ARTERY BYPASS GRAFTING: ANALYSIS AND OUTCOME
    Hussain, Raheel
    Soomro, Tariq Ishaq
    PAKISTAN HEART JOURNAL, 2008, 41 (1-2): : 5 - 9
  • [10] Off-Pump Versus On-Pump Coronary Artery Bypass Grafting
    Halkos, Michael E.
    Puskas, John D.
    SURGICAL CLINICS OF NORTH AMERICA, 2009, 89 (04) : 913 - +