共 39 条
Hemocompatible Control of Sulfobetaine-Grafted Polypropylene Fibrous Membranes in Human Whole Blood via Plasma-Induced Surface Zwitterionization
被引:74
作者:
Chen, Sheng-Han
[1
,2
]
Chang, Yung
[1
,2
]
Lee, Kueir-Rarn
[1
,2
]
Wei, Ta-Chin
[1
,2
]
Higuchi, Akon
[3
]
Ho, Feng-Ming
[4
]
Tsou, Chia-Chun
[5
]
Ho, Hsin-Tsung
[5
,6
]
Lai, Juin-Yih
[1
,2
]
机构:
[1] Chung Yuan Christian Univ, R&D Ctr Membrane Technol, Tao Yuan 320, Taiwan
[2] Chung Yuan Christian Univ, Dept Chem Engn, Tao Yuan 320, Taiwan
[3] Natl Cent Univ, Dept Chem & Mat Engn, Tao Yuan 320, Taiwan
[4] Tao Yuan Gen Hosp, Dept Hlth, Tao Yuan 320, Taiwan
[5] Mackay Mem Hosp, Taipei 104, Taiwan
[6] Mackay Med Coll, New Taipei City 252, Taiwan
来源:
关键词:
SELF-ASSEMBLED MONOLAYERS;
VON-WILLEBRAND-FACTOR;
PROTEIN ADSORPTION;
PLATELET-ADHESION;
POLYMER NETWORKS;
CARBOXYBETAINE;
FIBRINOGEN;
COMPATIBILITY;
RESISTANCE;
HYDROGELS;
D O I:
10.1021/la3036902
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
In this work, the hemocompatibility of zwitterionic polypropylene (PP) fibrous membranes with varying grafting coverage of poly(sulfobetaine methacrylate) (PSBMA) via plasma-induced surface polymerization was studied. Charge neutrality of PSBMA-grafted layers on PP membrane surfaces was controlled by the low-pressure and atmospheric plasma treatment in this study. The effects of grafting composition, surface hydrophilicity, and hydration capability on blood compatibility of the membranes were determined. Protein adsorption onto the different PSBMA-grafted PP membranes from human fibrinogen solutions was measured by enzyme-linked immunosorbent assay (ELISA) with monoclonal antibodies. Blood platelet adhesion and plasma clotting time measurements from a recalcified platelet-rich plasma solution were used to determine if platelet activation depends on the charge bias of the grafted PSBMA layer. The charge bias of PSBMA layer deviated from the electrical balance of positively and negatively charged moieties can be well-controlled via atmospheric plasma-induced interfacial zwitterionization and was further tested with human whole blood. The optimized PSBMA surface graft layer in overall charge neutrality has a high hydration capability and keeps its original blood-inert property of antifouling, anticoagulant, and antithrmbogenic activities when it comes into contact with human blood. This work suggests that the hemocompatible nature of grafted PSBMA polymers by controlling grafting quality via atmospheric plasma treatment gives a great potential in the surface zwitterionization of hydrophobic membranes for use in human whole blood.
引用
收藏
页码:17733 / 17742
页数:10
相关论文