共 26 条
Sensitive troponin assays and N-terminal pro-B-type natriuretic peptide in acute coronary syndrome: Prediction of significant coronary lesions and long-term prognosis
被引:27
作者:
Gravning, Jorgen
[1
,2
,3
]
Smedsrud, Marit Kristine
[1
,2
,3
]
Omland, Torbjorn
[3
,4
]
Eek, Christian
[2
]
Skulstad, Helge
[2
]
Aaberge, Lars
[2
]
Bendz, Bjorn
[2
]
Kjekshus, John
[2
,3
]
Morkrid, Lars
[5
]
Edvardsen, Thor
[1
,2
,3
]
机构:
[1] Oslo Univ Hosp, Rikshosp, Inst Surg Res, N-0027 Oslo, Norway
[2] Oslo Univ Hosp, Rikshosp, Dept Cardiol, N-0027 Oslo, Norway
[3] Univ Oslo, Ctr Heart Failure Res, Oslo, Norway
[4] Akershus Univ Hosp, Div Med, Lorenskog, Norway
[5] Oslo Univ Hosp, Rikshosp, Dept Med Biochem, N-0027 Oslo, Norway
关键词:
CHEST-PAIN PATIENTS;
MYOCARDIAL-INFARCTION;
EARLY-DIAGNOSIS;
I ASSAY;
T CONCENTRATIONS;
PERFORMANCE;
MORTALITY;
DEATH;
D O I:
10.1016/j.ahj.2013.02.008
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background Sensitive troponin assays have substantially improved early diagnosis of myocardial infarction. However, the role of sensitive cardiac troponin (cTn) assays in prediction of significant coronary lesions and long-term prognosis in non-ST-elevation acute coronary syndrome (NSTE-ACS) remains unresolved. Methods This prospective study includes 458 consecutive patients with NSTE-ACS admitted for coronary angiography. Serum levels of 4 commercial available sensitive troponin assays were analyzed (Roche high-sensitive cTnT [hs-cTnT; Roche Diagnostics, Basel, Switzerland], Siemens cTnI Ultra [Siemens, Munich, Germany], Abbott-Architect cTnI [Abbott, Abbott Park, IL], Access Accu-cTnI [Beckman Coulter, Nyon, Switzerland]), as well as a standard assay (Roche cTnT) and N-terminal pro-Btype natriuretic peptide (NT-proBNP), before coronary angiography. Results The relationship between the analyzed biomarkers and significant coronary lesions on coronary angiography, as quantified by area under the receiver operating characteristic curve, was significantly higher with Roche hs-cTnT, Siemens cTnI Ultra, and Access Accu-cTnI as compared with standard troponin T assay (P < .001 for all comparisons). This difference was mainly caused by increased sensitivity below the 99th percentile. Also, NT-proBNP was associated with the presence of significant coronary lesions. Cardiac troponin values were correlated with cardiac death (primary end point) during 1373 (1257-1478) days of follow-up. In both univariate and multivariate Cox regression analyses, NT-proBNP was superior to both hs-cTnT and cTnI in prediction of cardiovascular mortality. Troponin values with all assays were correlated with the need for repeated revascularization (secondary end point) during follow-up. Conclusions Sensitive cTn assays are superior to standard cTnT assay in prediction of significant coronary lesions in patients with NSTE-ACS. However, this improvement is primary caused by increased sensitivity below the 99th percentile. N-terminal pro-B-type natriuretic peptide is superior to cTns in prediction of long-term mortality. (Am Heart J 2013;165:716-24.)
引用
收藏
页码:716 / 724
页数:9
相关论文