Analytical Enzymatic Reactions in Microfluidic Chips

被引:9
作者
Lukyanenko, K. A. [1 ]
Denisov, I. A. [1 ]
Yakimov, A. S. [1 ]
Esimbekova, E. N. [1 ,2 ]
Belousov, K. I. [3 ]
Bukatin, A. S. [1 ]
Kukhtevich, I. V. [1 ]
Sorokin, V. V. [1 ]
Evstrapov, A. A. [3 ,4 ]
Belobrov, P. I. [1 ,2 ]
机构
[1] Siberian Fed Univ, Krasnoyarsk 660041, Russia
[2] Russian Acad Sci, Inst Biophys, Siberian Branch, Krasnoyarsk 660036, Russia
[3] St Petersburg Inst Fine Mech & Opt, St Petersburg 197101, Russia
[4] Inst Analyt Instrumentat, St Petersburg 198095, Russia
基金
俄罗斯科学基金会;
关键词
bioluminescence; luciferase; microfluidics; microfluidic chip; enzymatic bioassay; BIOAVAILABLE HEAVY-METALS; DEVICES; POINT; LAB;
D O I
10.1134/S0003683817070043
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A number of approaches have been proposed and tested to transfer enzymatic reactions into the functional elements of microfluidic chips on the example of the bienzyme bioluminescent reaction involving NAD(P)H:FMN-oxidoreductase and luciferase. Measurement of the catalytic activity of these enzymes (under the influence of pollutants) is the basis of enzymatic bioassay of various liquids. It was found that all of the components of the reaction must be placed in the same cell of the chip to improve the reproducibility of the measurements. The use of starch gel as a carrier for immobilization and gelatin as a scaffold in the reactor of the chip enables the preservation of enzyme activity in the course of sealing the chip at room temperature. It is shown that the components of the reaction should be vigorously stirred in a microfluidic chip reactor to improve the efficiency of the analysis. As a result of the studies, a prototype of microfluidic chip based on the enzymatic bioluminescent reaction is proposed. It is characterized by a detection limit of copper sulfate of 3 mu M that corresponds to the sensitivity of traditional lux-biosensors based on living cells. The analysis time is reduced to 1 min, and the analysis can be performed by individuals without special laboratory skills.
引用
收藏
页码:775 / 780
页数:6
相关论文
共 16 条
  • [1] Gelatin and starch as stabilizers of the coupled enzyme system of luminous bacteria NADH:FMN-oxidoreductase-luciferase
    Bezrukikh, Anna
    Esimbekova, Elena
    Nemtseva, Elena
    Kratasyuk, Valentina
    Shimomura, Osamu
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (23) : 5743 - 5747
  • [2] Microfluidic fabrication of microengineered hydrogels and their application in tissue engineering
    Chung, Bong Geun
    Lee, Kwang-Ho
    Khademhosseini, Ali
    Lee, Sang-Hoon
    [J]. LAB ON A CHIP, 2012, 12 (01) : 45 - 59
  • [3] Microfluidic chips for biological and medical research
    Evstrapov, A. A.
    [J]. RUSSIAN JOURNAL OF GENERAL CHEMISTRY, 2012, 82 (12) : 2132 - 2145
  • [4] Point of Care Diagnostics: Status and Future
    Gubala, Vladimir
    Harris, Leanne F.
    Ricco, Antonio J.
    Tan, Ming X.
    Williams, David E.
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (02) : 487 - 515
  • [5] Micromilling: a method for ultra-rapid prototyping of plastic microfluidic devices
    Guckenberger, David J.
    de Groot, Theodorus E.
    Wan, Alwin M. D.
    Beebe, David J.
    Young, Edmond W. K.
    [J]. LAB ON A CHIP, 2015, 15 (11) : 2364 - 2378
  • [6] Detection of bioavailable heavy metals in EILATox-Oregon samples using whole-cell luminescent bacterial sensors in suspension or immobilized onto fibre-optic tips
    Hakkila, K
    Green, T
    Leskinen, P
    Ivask, A
    Marks, R
    Virta, M
    [J]. JOURNAL OF APPLIED TOXICOLOGY, 2004, 24 (05) : 333 - 342
  • [7] Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
    Jung, Woos Eok
    Han, Jungyoup
    Choi, Jin-Woo
    Ahn, Chong H.
    [J]. MICROELECTRONIC ENGINEERING, 2015, 132 : 46 - 57
  • [8] Applications of Luminous Bacteria Enzymes in Toxicology
    Kratasyuk, Valentina A.
    Esimbekova, Elena N.
    [J]. COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2015, 18 (10) : 952 - 959
  • [9] Leth S, 2002, ELECTROANAL, V14, P35, DOI 10.1002/1521-4109(200201)14:1<35::AID-ELAN35>3.0.CO
  • [10] 2-W