Evaluating the Severity of Nonalcoholic Steatohepatitis With Superparamagnetic Iron Oxide-Enhanced Magnetic Resonance Imaging

被引:21
|
作者
Tornita, Kengo [1 ]
Tanimoto, Akihiro [2 ]
Irie, Rie [3 ]
Kikuchi, Masahiro [1 ]
Yokoyama, Hirokazu [4 ]
Teratani, Toshiaki [1 ]
Suzuki, Takahiro [1 ]
Taguchi, Takashi [1 ]
Noguchi, Masaaki [5 ]
Ohkura, Tamiko [5 ]
Hibi, Toshifumi [1 ]
机构
[1] Keio Univ, Dept Internal Med, Sch Med, Div Gastroenterol & Hepatol,Shinjuku Ku, 35 Shinanomachi, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo 1608582, Japan
[3] Keio Univ, Sch Med, Dept Diagnost Pathol, Tokyo 1608582, Japan
[4] Keio Univ, Sch Med, Ctr Hlth, Tokyo 1608582, Japan
[5] Keio Univ, Sch Med, Inst Adv Med Res, Tokyo 1608582, Japan
关键词
nonalcoholic steatohepatitis; nonalcoholic fatty liver disease; superparamagnetic iron oxide; magnetic resonance imaging;
D O I
10.1002/jmri.21596
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the utility of noninvasive assessment of human nonalcoholic fatty liver disease (NAFLD) patients using superparamagnetic iron oxide (SPIO)-enhanced MRI. Materials and Methods: Nineteen NAFLD patients underwent SPIO-enhanced MRI. The values of tau. a time constant for an exponential approximation. were calculated using gradient-echo echo-planar imaging, and the values of %T2, a marker of the T2 relaxation effect of SPIO, were calculated using T2-weighted fast spin-echo images. Correlations between these values and the histological NAFLD activity scores were evaluated. The study protocol was approved by our Institutional Review Board and all patients gave informed consent. Results: There was a statistically significant relationship between the NAFLD activity scores and the T values (r = 0.66, P = 0.002). The %T2 values were also significantly correlated with the NAFLD activity score (r = -0.58, P = 0.009). A Cutoff T value of 42.8 predicted "definitive NASH" (NAFLD activity score 5) with a specificity of 66.7% and a sensitivity of 99.9%, whereas a cutoff %T2 value of 32.5 predicted "definitive NASH" with a specificity of 72.7% and a sensitivity of 87.5%. Conclusion: Noninvasive SPIO-enhanced MRI may be helpful for identifying NASH patients among patients suspected of having NAFLD.
引用
收藏
页码:1444 / 1450
页数:7
相关论文
共 50 条
  • [21] Current status of superparamagnetic iron oxide contrast agents for liver magnetic resonance imaging
    Yi-Xiang J Wang
    World Journal of Gastroenterology, 2015, (47) : 13400 - 13402
  • [22] Predictability of FTY720 efficacy in experimental autoimmune encephalomyelitis by in vivo macrophage tracking: Clinical implications for ultrasmall superparamagnetic iron oxide-enhanced magnetic resonance imaging
    Rausch, M
    Hiestand, P
    Foster, CA
    Baumann, DR
    Cannet, C
    Rudin, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (01) : 16 - 24
  • [23] CD14 expression and Kupffer cell dysfunction in non-alcoholic steatohepatitis: Superparamagnetic iron oxide-magnetic resonance image and pathologic correlation
    Tonan, Tatsuyuki
    Fujimoto, Kiminori
    Qayyum, Aliya
    Morita, Yasuyo
    Nakashima, Osamu
    Ono, Noriyuki
    Kawahara, Akihiko
    Kage, Masayoshi
    Hayabuchi, Naofumi
    Ueno, Takato
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 (04) : 789 - 796
  • [24] Hepatic adenoma and focal nodular hyperplasia: MR findings with superparamagnetic iron oxide-enhanced MRI
    Beets-Tan, RGH
    Van Engelshoven, JMA
    Greve, JWM
    CLINICAL IMAGING, 1998, 22 (03) : 211 - 215
  • [25] Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles
    Schmitz, SA
    Taupitz, M
    Wagner, S
    Wolf, KJ
    Beyersdorff, D
    Hamm, B
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 355 - 361
  • [26] Detection and characterization of focal liver lesions using superparamagnetic iron oxide-enhanced magnetic resonance imaging: comparison between ferumoxides-enhanced T1-weighted imaging and delayed-phase gadolinium-enhanced T1-weighted imaging
    Takahama, K
    Amano, Y
    Hayashi, H
    Ishihara, M
    Kumazaki, T
    ABDOMINAL IMAGING, 2003, 28 (04) : 525 - 530
  • [27] Experimental Study of Ultrafine Superparamagnetic Iron Oxide-Enhanced MRI in an Atherosclerotic Plaque Mode
    Chen, Xinjian
    Li, Xia
    Chen, Qiong
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (12) : 7444 - 7450
  • [28] Study on ASTC-a-1 cells labeled with superparamagnetic iron oxide and its magnetic resonance imaging
    Yu, Ming-Xi
    Chen, Wen-Li
    Zhou, Quan
    Gao, Peng
    EXPERIMENTAL BIOLOGY AND MEDICINE, 2010, 235 (09) : 1053 - 1061
  • [29] Magnetic resonance imaging of ruptured plaques in the rabbit with ultrasmall superparamagnetic particles of iron oxide
    Durand, E.
    Raynaud, J. S.
    Bruneval, P.
    Brigger, I.
    Al Haj Zen, A.
    Mandet, C.
    Lancelot, E.
    Lafont, A.
    JOURNAL OF VASCULAR RESEARCH, 2007, 44 (02) : 119 - 128
  • [30] Superparamagnetic iron-oxide-enhanced diffusion-weighted magnetic resonance imaging for the diagnosis of intrapancreatic accessory spleen
    Ishigami, Kousei
    Nishie, Akihiro
    Nakayama, Tomohiro
    Asayama, Yoshiki
    Kakihara, Daisuke
    Fujita, Nobuhiro
    Ushijima, Yasuhiro
    Okamoto, Daisuke
    Ohtsuka, Takao
    Mori, Yasuhisa
    Ito, Tetsuhide
    Mochidome, Naoki
    Honda, Hiroshi
    ABDOMINAL RADIOLOGY, 2019, 44 (10) : 3325 - 3335