Evaluating the Severity of Nonalcoholic Steatohepatitis With Superparamagnetic Iron Oxide-Enhanced Magnetic Resonance Imaging

被引:21
|
作者
Tornita, Kengo [1 ]
Tanimoto, Akihiro [2 ]
Irie, Rie [3 ]
Kikuchi, Masahiro [1 ]
Yokoyama, Hirokazu [4 ]
Teratani, Toshiaki [1 ]
Suzuki, Takahiro [1 ]
Taguchi, Takashi [1 ]
Noguchi, Masaaki [5 ]
Ohkura, Tamiko [5 ]
Hibi, Toshifumi [1 ]
机构
[1] Keio Univ, Dept Internal Med, Sch Med, Div Gastroenterol & Hepatol,Shinjuku Ku, 35 Shinanomachi, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo 1608582, Japan
[3] Keio Univ, Sch Med, Dept Diagnost Pathol, Tokyo 1608582, Japan
[4] Keio Univ, Sch Med, Ctr Hlth, Tokyo 1608582, Japan
[5] Keio Univ, Sch Med, Inst Adv Med Res, Tokyo 1608582, Japan
关键词
nonalcoholic steatohepatitis; nonalcoholic fatty liver disease; superparamagnetic iron oxide; magnetic resonance imaging;
D O I
10.1002/jmri.21596
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the utility of noninvasive assessment of human nonalcoholic fatty liver disease (NAFLD) patients using superparamagnetic iron oxide (SPIO)-enhanced MRI. Materials and Methods: Nineteen NAFLD patients underwent SPIO-enhanced MRI. The values of tau. a time constant for an exponential approximation. were calculated using gradient-echo echo-planar imaging, and the values of %T2, a marker of the T2 relaxation effect of SPIO, were calculated using T2-weighted fast spin-echo images. Correlations between these values and the histological NAFLD activity scores were evaluated. The study protocol was approved by our Institutional Review Board and all patients gave informed consent. Results: There was a statistically significant relationship between the NAFLD activity scores and the T values (r = 0.66, P = 0.002). The %T2 values were also significantly correlated with the NAFLD activity score (r = -0.58, P = 0.009). A Cutoff T value of 42.8 predicted "definitive NASH" (NAFLD activity score 5) with a specificity of 66.7% and a sensitivity of 99.9%, whereas a cutoff %T2 value of 32.5 predicted "definitive NASH" with a specificity of 72.7% and a sensitivity of 87.5%. Conclusion: Noninvasive SPIO-enhanced MRI may be helpful for identifying NASH patients among patients suspected of having NAFLD.
引用
收藏
页码:1444 / 1450
页数:7
相关论文
共 50 条
  • [1] Superparamagnetic iron oxide-enhanced magnetic resonance imaging of the liver in beagle dogs
    Chang, D
    Kim, B
    Yun, Y
    Hur, Y
    Lee, Y
    Choi, M
    Yoon, J
    Seong, J
    VETERINARY RADIOLOGY & ULTRASOUND, 2002, 43 (01) : 37 - 42
  • [2] Superparamagnetic Iron Oxide-Enhanced Magnetic Resonance Imaging in a Case of Spleen Hamartoma
    Bulakci, Mesut
    Yilmaz, Erdem
    Yahyayev, Aghakishi
    Bulakci, Betul Bozkurt
    Yekeler, Ensar
    MEDICAL PRINCIPLES AND PRACTICE, 2013, 22 (03) : 301 - 303
  • [3] Ultrasmall superparamagnetic iron oxide-enhanced magnetic resonance Imaging in experimental autoimmune encephalitis
    Bendszus, M
    Stoll, G
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (06) : 850 - 850
  • [4] Superparamagnetic iron oxide-enhanced magnetic resonance for imaging cardiac inflammation. A minireview
    Podrouzkova, Helena
    Feitova, Vera
    Panovsky, Roman
    Meluzin, Jaroslav
    Orban, Marek
    BIOMEDICAL PAPERS-OLOMOUC, 2015, 159 (03): : 378 - 381
  • [5] Focal nodular hyperplasia of the liver: usefulness of superparamagnetic iron oxide-enhanced magnetic resonance imaging
    Okada, T
    Sasaki, F
    Kamiyama, T
    Nakagawa, T
    Nakanishi, K
    Kobayashi, R
    Itoh, T
    Ota, S
    Todo, S
    JOURNAL OF PEDIATRIC SURGERY, 2005, 40 (03) : E21 - E25
  • [6] Superparamagnetic Iron Oxide-Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain
    Thorek, Daniel L. J.
    Weisshaar, Christine L.
    Czupryna, Julie C.
    Winkelstein, Beth A.
    Tsourkas, Andrew
    MOLECULAR IMAGING, 2011, 10 (03) : 206 - 214
  • [7] Intrathoracic splenosis: evaluation by superparamagnetic iron oxide-enhanced magnetic resonance imaging and radionuclide scintigraphy
    Ishibashi, Mana
    Tanabe, Yoshio
    Miyoshi, Hidenao
    Matusue, Eiji
    Kaminou, Toshio
    Ogawa, Toshihide
    JAPANESE JOURNAL OF RADIOLOGY, 2009, 27 (09) : 371 - 374
  • [8] Intrathoracic splenosis: evaluation by superparamagnetic iron oxide-enhanced magnetic resonance imaging and radionuclide scintigraphy
    Mana Ishibashi
    Yoshio Tanabe
    Hidenao Miyoshi
    Eiji Matusue
    Toshio Kaminou
    Toshihide Ogawa
    Japanese Journal of Radiology, 2009, 27 : 371 - 374
  • [9] Detection of small primary and secondary malignant hepatic tumors with superparamagnetic iron oxide-enhanced, magnetic resonance imaging
    Vajragapta, Laddawan
    Tumkosit, Monravee
    Pantongrag-Brown, Linda
    Wangsuphachart, Somjai
    ASIAN BIOMEDICINE, 2008, 2 (02) : 135 - 139
  • [10] Superparamagnetic Iron Oxide-enhanced Magnetic Resonance Imaging of Spontaneous Hepatic Neoplasia in a Cynomolgus Macaque (Macaca fascicularis)
    Fujishiro, Yasuyo Ito
    Koie, Hiroshi
    Nakayama, Shunya
    Shibata, Hiroaki
    Okabayashi, Sachi
    Katakai, Yuko
    Kanayama, Kiichi
    Yasutomi, Yasuhiro
    Ageyama, Naohide
    COMPARATIVE MEDICINE, 2018, 68 (03) : 233 - 238