Magnetically controlled fluorescence aptasensor for simultaneous determination of ochratoxin A and aflatoxin B1

被引:83
|
作者
Qian, Jing [1 ]
Ren, Chanchan [1 ]
Wang, Chengquan [2 ]
Chen, Wei [1 ]
Lu, Xiaoting [1 ]
Li, Henan [1 ]
Liu, Qian [1 ]
Hao, Nan [1 ]
Li, Huaming [1 ]
Wang, Kun [1 ]
机构
[1] Jiangsu Univ, Sch Chem & Chem Engn, Zhenjiang 212013, Peoples R China
[2] Jiangsu Univ, Sch Food & Biol Engn, Zhenjiang 212013, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Fluorescence aptasensor; Magnetic separation; Simultaneous determination; Ochratoxin A; Aflatoxins B1; UP-CONVERSION NANOPARTICLES; CDTE QUANTUM DOTS; RESONANCE ENERGY-TRANSFER; NECROSIS-FACTOR-ALPHA; ELECTROCHEMICAL APTASENSOR; ULTRASENSITIVE DETECTION; SILICA NANOSPHERE; GRAPHENE OXIDE; FUMONISIN B1; B-1;
D O I
10.1016/j.aca.2018.02.063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Development of an efficient method for the simultaneous detection of two highly concerning mycotoxins, ochratoxin A (OTA) and aflatoxin B1 (AFB1), is of great significance on food safety monitoring. Herein, a magnetically controlled fluorescence aptasensor for simultaneous determination of OTA and AFB1 has been successfully developed. The working principle of the aptasensor is based on the specific aptamer-mycotoxin recognition and further leads to the partial release of two distinguishable fluorescence labels from the magnetic carriers. Through the magnetic separation, the reporter probes in the supernatant solution can be collected and converted into a sensitive fluorescence signal with dual emission peaks. This aptasensor provided a wide detection range of 2 pg mL(-1) - 5 ng mL(-1) for OTA and 5 pg mL(-1) - 10 ng mL(-1) for AFB1. The new easy-to-wash and simple-to-use approach offers a simultaneous and high selective detection with high sensitivity (limits of detection of 0.67 and 1.70 pg mL(-1) for OTA and AFB1, respectively). Remarkable accuracy (relative standard deviation <5.6%) during the mycotoxins determination as well as excellent quantitative recoveries (95-108%) during the analysis of the spiked corn samples were also achieved. This simple aptasensing scheme provides a new avenue for high throughput screen of dual mycotoxins due to its simple manipulation, short assay times, high selectivity and sensitivity. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:119 / 127
页数:9
相关论文
共 50 条
  • [1] Exonuclease III assisted electrochemical aptasensor simultaneous detection of aflatoxin B1 and ochratoxin a in grains
    Liu, Xiaoran
    Zhang, Yunzhe
    Wang, Yu
    Xu, Hui
    Lu, Xin
    Ma, Xiaoyan
    Zhang, Wei
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2024, 201
  • [2] Acoustic Aptasensor for Aflatoxin B1 Determination
    Spinella, Katia
    Mosiello, Lucia
    Poturnayova, Alexandra
    Sneyedarkova, Maya
    Hianik, Tibor
    SENSORS, 2015, 319 : 71 - 75
  • [3] Potential hazard of simultaneous occurrence of aflatoxin B1 and ochratoxin A
    Sedmíková, M
    Reisnerová, H
    Dufková, Z
    Barta, I
    Jílek, F
    VETERINARNI MEDICINA, 2001, 46 (06) : 169 - 174
  • [4] Simultaneous Determination of Aflatoxin B1 and Ochratoxin A in Cereals by a Novel Electrochemical Aptasensor Using Metal-Organic Framework as Signal Carrier
    Xu, Yiwei
    Jia, Xupeng
    Yang, Sennan
    Cao, Mengrui
    He, Baoshan
    Ren, Wenjie
    Suo, Zhiguang
    FOODS, 2024, 13 (14)
  • [5] An ultrasensitive electrochemical aptasensor based on different oxidation nanoprobes for single or simultaneous detection of aflatoxin B1 and ochratoxin A
    Liu, Yongxin
    Chen, Pengsheng
    Lin, Kaiyu
    Zhou, Qing
    Zhou, Lin
    Zhai, Haiyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 432
  • [6] Magnetically controlled fluorescence biosensor for simultaneous detection of aflatoxin B1 and its toxin-producing gene aflD
    Li, Yaqi
    Peng, Shuangfeng
    Chen, Xin
    Sun, Danni
    Zuo, Xiang
    Liu, Chang
    Zhang, Qi
    Li, Shijie
    Ye, Hua
    Kong, Dezhao
    FOOD BIOSCIENCE, 2025, 64
  • [7] Simultaneous determination of aflatoxin B1 and ochratoxin A and their natural occurrence in Mediterranean virgin olive oil
    Ferracane, R.
    Tafuri, A.
    Logieco, A.
    Galvano, F.
    Balzano, D.
    Ritieni, A.
    FOOD ADDITIVES AND CONTAMINANTS, 2007, 24 (02): : 173 - 180
  • [8] Simultaneous Detection of Ochratoxin A and Aflatoxin B1 Based on Stable Tuning Fork-shaped DNA Fluorescent Aptasensor
    Wang, Mengyao
    Lv, Zeping
    Liu, Yong
    Wei, Min
    JOURNAL OF FLUORESCENCE, 2024,
  • [9] A Novel Fluorescent Aptasensor Based on Dual-labeled DNA Nanostructure for Simultaneous Detection of Ochratoxin A and Aflatoxin B1
    Luyang Zhao
    Xiujun Liang
    Yong Liu
    Min Wei
    Huali Jin
    Journal of Fluorescence, 2023, 33 : 1641 - 1650
  • [10] A Novel Fluorescent Aptasensor Based on Dual-labeled DNA Nanostructure for Simultaneous Detection of Ochratoxin A and Aflatoxin B1
    Zhao, Luyang
    Liang, Xiujun
    Liu, Yong
    Wei, Min
    Jin, Huali
    JOURNAL OF FLUORESCENCE, 2023, 33 (04) : 1641 - 1650