EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study

被引:104
作者
Kandel, Pujan [1 ]
Tranesh, Ghassan [2 ]
Nassar, Aziza [2 ]
Bingham, Russell [1 ]
Raimondo, Massimo [1 ]
Woodward, Timothy A. [1 ]
Gomez, Victoria [1 ]
Wallace, Michael B. [1 ]
机构
[1] Mayo Clin, Dept Gastroenterol & Hepatol, Jacksonville, FL 32224 USA
[2] Mayo Clin, Dept Pathol, Jacksonville, FL 32224 USA
关键词
SOLID PANCREATIC MASSES; TRUCUT NEEDLE; ENDOSCOPIC ULTRASONOGRAPHY; TISSUE ACQUISITION; ASPIRATION; FNA; DIAGNOSIS; LESIONS; LYMPHADENOPATHY; METAANALYSIS;
D O I
10.1016/j.gie.2016.03.1405
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: EUS-guided fine needle biopsy (FNB) sampling and FNA are important methods for obtaining core tissues and cytologic aspirates. To improve the specimen quality for pathologic evaluation, a novel EUS-FNB Shark Core (SC) needle has been designed to acquire core tissue during EUS procedures. We compared the histology yield of EUS-FNB sampling using the SC needle (EUS-FNB-SC) to EUS-FNA in patients who had solid pancreatic and nonpancreatic lesions. Methods: This was a retrospective case-control study design. Between July 2012 and July 2015 all patients who had EUS-FNB-SC and EUS-FNA were reviewed through a hospital EUS database. Consecutive samples from EUS-FNB-SCs were matched in a 1:3 ratio by lesion site (eg, pancreatic head) and needle gauge (ie, 19 gauge, 22 gauge, 25 gauge) to recent random samples of EUS-FNA. The procedures were performed with rapid onsite evaluation. For study purposes specimen slides were evaluated by 2 cytopathologists for histologic yield using a standard scoring system (0 = no material, 1-2 = cytologic, 3-5 = histologic). The main objectives were to assess the histologic yield of the samples and compare the median number of passes required to obtain core tissue by using EUS-FNB-SC and EUS-FNA needles. Results: Of the 156 patients included in study, 25% patients (n = 39) were in the EUS-FNB-SC group and 75% (n = 117) in the EUS-FNA group. According to standard scoring criteria for histology, the median histology score for EUS-FNA was 2 (sufficient for cytology but not histology) and for EUS-FNB-SC was 4 (sufficient for adequate histology). Ninety-five percent of the specimens obtained from the EUS-FNB-SC group were of sufficient size for histologic screening, compared with 59% from the EUS-FNA group (P = .01). The median number of passes required to achieve a sample was significantly lower in the EUS-FNB-SC group compared with the EUS-FNA group (2 passes vs 4 passes, P = .001). There was significant difference in the median number of passes to all lesion sites and needle gauges. Conclusions: The histology yield was significantly higher using the EUS-FNB-SC needle compared with the EUS-FNA needle. Additionally, fewer passes were required to obtain histology cores when using EUS-FNB-SC.
引用
收藏
页码:1034 / 1039
页数:6
相关论文
共 50 条
  • [21] Comparison of FNA and fine- needle biopsy for EUS-guided sampling of suspected GI stromal tumors
    El Chafic, Abdul Hamid
    Loren, David
    Siddiqui, Ali
    Mounzer, Rawad
    Cosgrove, Natalie
    Kowalski, Thomas
    GASTROINTESTINAL ENDOSCOPY, 2017, 86 (03) : 510 - 515
  • [22] The diagnostic and cellularity yield of reverse bevel versus fork-tip fine needle biopsy
    Abdelfatah, Mohamed M.
    Hamed, Ahmed
    Koutlas, Nicholas J.
    Aly, F. Zahra
    DIAGNOSTIC CYTOPATHOLOGY, 2018, 46 (08) : 649 - 655
  • [23] Prospective, multicenter, observational study of tissue acquisition through EUS-guided fine-needle biopsy using a 25G Franseen needle
    Sugiura, Ryo
    Kuwatani, Masaki
    Yane, Kei
    Taya, Yoko
    Ihara, Hideyuki
    Onodera, Manabu
    Eto, Kazunori
    Sano, Itsuki
    Kudo, Taiki
    Mitsuhashi, Tomoko
    Katanuma, Akio
    Sakamoto, Naoya
    ENDOSCOPIC ULTRASOUND, 2019, 8 (05) : 321 - 328
  • [24] EUS-guided needle biopsy for autoimmune pancreatitis
    Chhoda, Ankit
    Rustagi, Tarun
    CLINICAL JOURNAL OF GASTROENTEROLOGY, 2020, 13 (05) : 669 - 677
  • [25] Lymphadenopathy Tissue Sampling by EUS-Guided Fine-Needle Biopsy Contributes to Meeting the Conditions for Genomic Profiling
    Sugimoto, Mitsuru
    Takagi, Tadayuki
    Suzuki, Rei
    Konno, Naoki
    Asama, Hiroyuki
    Sato, Yuki
    Irie, Hiroki
    Nakamura, Jun
    Takasumi, Mika
    Hashimoto, Minami
    Kato, Tsunetaka
    Hashimoto, Yuko
    Hikichi, Takuto
    Ohira, Hiromasa
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2025, 59 (04) : 369 - 375
  • [26] EUS-Guided Biopsy with a Novel Puncture Biopsy Forceps Needle-Feasibility Study
    Litjens, Geke
    Gerges, Christian
    Shastri, Yogesh M.
    Somani, Piyush
    Beyna, Torsten
    Neuhaus, Horst
    van Laarhoven, Cornelis J. H. M.
    Prokop, Mathias
    Siersema, Peter D.
    Hermans, John J.
    van Geenen, Erwin J. M.
    DIAGNOSTICS, 2021, 11 (09)
  • [27] EUS-guided needle biopsy for autoimmune pancreatitis
    Ankit Chhoda
    Tarun Rustagi
    Clinical Journal of Gastroenterology, 2020, 13 : 669 - 677
  • [28] The impact of macroscopic on-site evaluation using filter paper in EUS-guided fine-needle biopsy
    Oh, Dongwook
    Seo, Dong-Wan
    Hong, Seung-Mo
    Song, Tae Jun
    Park, Do Hyun
    Lee, Sang Soo
    Lee, Sung Koo
    Kim, Myung-Hwan
    ENDOSCOPIC ULTRASOUND, 2019, 8 (05) : 342 - 347
  • [29] Novel fork-tip needles versus standard needles for EUS-guided tissue acquisition from solid masses of the upper GI tract: a matched cohort study
    Jovani, Manol
    Abidi, Wasif M.
    Lee, Linda S.
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2017, 52 (6-7) : 784 - 787
  • [30] Feasibility of a 20-gauge ProCore needle in EUS-guided subepithelial tumor sampling: a prospective multicenter study
    Kim, Do Hoon
    Kim, Gwang Ha
    Cho, Chang Min
    Park, Chang Hwan
    Na, Soo-Young
    Kim, Tae Hyeon
    Cho, Yu Kyung
    Kim, Ji Hyun
    Seo, Dong-Wan
    BMC GASTROENTEROLOGY, 2018, 18