Retrieval analysis of squeaking ceramic implants: Are there related specific features?

被引:22
作者
Chevillotte, C. [1 ,2 ]
Trousdale, R. T. [3 ]
An, K. -N. [4 ]
Padgette, D. [5 ]
Wright, T. [5 ]
机构
[1] Hop Edouard Herriot, Dept Orthopaed Surg, F-69437 Lyon 03, France
[2] Univ Lyon 1, LBMC INRETS URMT 9406, Shocks Biomech Res Lab, F-69365 Lyon, France
[3] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55902 USA
[4] Mayo Clin, Biomech Lab, Rochester, MN 55902 USA
[5] Hosp Special Surg, New York, NY 10021 USA
关键词
Squeaking; Total hip arthroplasty; Ceramic; Surface bearing; Metal transfer; Stripe wear; TOTAL HIP-REPLACEMENT; BEARINGS;
D O I
10.1016/j.otsr.2011.12.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Ceramic-on-ceramic total hip arthroplasty is routinely used for young and active patients with end stage of hip osteoarthritis. However, squeaking noise is a recently identified problem with such bearing surface. Many in vivo and in vitro studies have been conducted trying to find the potential causes of this phenomenon. However, we are not aware of any study analyzing retrieved ceramic implants for squeaking. Hypothesis: Our primary hypothesis was that the surface analysis of retrieved ceramic implants with squeaking would present interesting deteriorations that could explain the squeaking noise. Materials and methods: Nine retrieved squeaking implants from ceramic-on-ceramic total hip arthroplasty that were retrieved for various reasons (two exclusively for squeaking, four for recurrent dislocation, one for aseptic loosening and two for instability) were analyzed. Implant positioning was calculated, macroscopic damages were noticed and microscopic roughness was analyzed. The retrieved implants were then tested on a hip simulator reproducing flexion/extension motions in several situations in lubricated and non-lubricated conditions in order to reproduce squeaking. Results: Five cups were considered with borderline insufficient anteversion. Gross impingement damage was visible on seven implants. All the retrieved heads had visible metal transfer on their surface. Eight implants had visible stripe wear. Microscopic analysis showed roughness higher than six microns on the retrieved heads. Squeaking was reproduced in vitro in dry conditions. In lubricated conditions, squeaking did not occur for the retrieved hips. Discussion: This retrieval analysis suggests that problems of cup orientation and design which can lead to impingement can generate lubrication problems because of metal transfer plus/minus stripe wear which is a common theme in ceramic-on-ceramic bearings that squeak. Level of evidence: Level IV, retrospective study. (c) 2012 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 24 条
[1]   ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]   Early results of primary Birmingham hip resurfacings - An independent prospective study of the first 230 hips [J].
Back, DL ;
Dalziel, R ;
Young, D ;
Shimmin, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (03) :324-329
[3]   Concerns about ceramics in THA [J].
Barrack, RL ;
Barak, C ;
Skinner, HB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :73-79
[4]   The 2009 Frank Stinchfield Award "Hip Squeaking'' A Biomechanical Study of Ceramic-on-ceramic Bearing Surfaces [J].
Chevillotte, Christophe ;
Trousdale, Robert T. ;
Chen, Qingshan ;
Guyen, Olivier ;
An, Kai-Nan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :345-350
[5]   A titanium-encased alumina ceramic bearing for total hip arthroplasty - 3-to 5-year results [J].
D'Antonio, JA ;
Capello, WN ;
Manley, MT ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :151-158
[6]  
D'Antonio JA, 2011, CLIN ORTHOP RELAT RE
[7]  
DORLOT JM, 1992, CLIN ORTHOP RELAT R, P47
[8]   Squeaking in total hip replacement: No cause fop concern [J].
Ecker, T. M. ;
Robbins, C. ;
van Flandern, G. ;
Patch, D. ;
Steppacher, S. D. ;
Bierbaum, B. ;
Murphy, Stephen B. .
ORTHOPEDICS, 2008, 31 (09) :875-+
[9]   The Squeaking Hip: A Phenomenon of Ceramic-on-Ceramic Total Hip Arthroplasty [J].
Jarrett, Christopher A. ;
Ranawat, Amar S. ;
Bruzzone, Matteo ;
Blum, Yossef C. ;
Rodriguez, Jose A. ;
Ranawat, Chitranjan S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06) :1344-1349
[10]   High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings [J].
Keurentjes, J. C. ;
Kuipers, R. M. ;
Wever, D. J. ;
Schreurs, B. W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (06) :1438-1443