Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour Collars

被引:67
作者
Wang, Shunyi [1 ]
Wei, Kai [1 ]
Shen, Zhonghui [1 ]
Xiang, Qiqi [1 ]
机构
[1] Southwest Jiaotong Univ, Dept Bridge Engn, Chengdu 610031, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
cylindrical pier; local scour; anti-scour collar; bridge; experiment; scour protection; scour development; optimal design; FLOW-ALTERING COUNTERMEASURES; FOUNDATION GEOMETRY; PILE; REDUCTION;
D O I
10.3390/w11071515
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Local scour of bridge piers is one of the main threats responsible for bridge damage. Adopting scour countermeasures to protect bridge foundations from scour has become an important issue for the design and maintenance of bridges located in erodible sediment beds. This paper focuses on the protective effect of one active countermeasure named an anti-scour collar on local scour around the commonly used cylindrical bridge pier. A cylindrical pier model was set up in a current flume. River sand with a median particle size of 0.324 mm was selected and used as the sediment in the basin. A live-bed scour experimental program was carried out to study the protective effect of an anti-scour collar by comparing the local scour at a cylindrical bridge pier model with and without collar. The effects of three design parameters including collar installation height, collar external diameter and collar protection range, on the scour depth and scour development were investigated parametrically. According to the experimental results, it can be concluded that: the application of an anti-scour collar alleviates the local scour at the pier effectively; and the protection effect decreases with an increase in the collar installation height, but increases with an increase in the collar external diameter and the protection range. Design suggestions for improving the scour protective effect of the anti-scour collar are summarized and of great practical guiding significance to the development of anti-scour collars for bridge piers.
引用
收藏
页数:19
相关论文
共 47 条
[1]  
[Anonymous], 1997, OCEANOGR LIT REV
[2]   Experimental investigation of clear-water local scour at pile groups [J].
Ataie-Ashtiani, B. ;
Beheshti, A. A. .
JOURNAL OF HYDRAULIC ENGINEERING, 2006, 132 (10) :1100-1104
[3]   Local scour at abutments: A review [J].
Barbhuiya, AK ;
Dey, S .
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2004, 29 (5) :449-476
[4]   Bayesian neural networks for prediction of equilibrium and time-dependent scour depth around bridge piers [J].
Bateni, S. Mohyeddin ;
Jeng, Dong-Sheng ;
Melville, Bruce W. .
ADVANCES IN ENGINEERING SOFTWARE, 2007, 38 (02) :102-111
[5]   Quantitative Spatio-Temporal Characterization of Scour at the Base of a Cylinder [J].
Bouratsis, Pol ;
Diplas, Panayiotis ;
Dancey, Clinton L. ;
Apsilidis, Nikolaos .
WATER, 2017, 9 (03)
[6]  
CHEN SC, 2018, WATER-SUI, V10, DOI DOI 10.3390/w10091251
[7]  
[成兰艳 Cheng Lanyan], 2012, [水利水电科技进展, Advances in Science and Technology of Water Resources], V32, P14
[8]   SCOUR PROTECTION AT BRIDGE PIERS [J].
CHIEW, YM .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1992, 118 (09) :1260-1269
[9]  
Clopper P.E., 2007, 593 NCHRP
[10]  
Ettema R., 1980, Scour at bridge piers