Intracranial aneurysms:: Detection with gadolinium-enhanced dynamic three-dimensional MR angiography -: Initial results

被引:72
作者
Metens, T [1 ]
Rio, F [1 ]
Balériaux, D [1 ]
Roger, T [1 ]
David, P [1 ]
Rodesch, G [1 ]
机构
[1] Free Univ Brussels, Hop Erasme, Unite RMN, Dept Radiol, B-1070 Brussels, Belgium
关键词
aneurysm; intracranial; MR; cerebral blood vessels; magnetic resonance (MR); angiography; three-dimensional;
D O I
10.1148/radiology.216.1.r00jl1139
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the clinical utility and accuracy of contrast material-enhanced dynamic three-dimensional (3D) T1-weighted magnetic resonance (MR) angiography in the detection of unruptured intracranial aneurysms. MATERIALS AND METHODS: A prospective blinded comparison of 3D contrast-enhanced T1-weighted MR angiography with 3D inflow magnetization transfer and tilted optimized nonsaturating excitation (MT TONE) imaging, phase-contrast MR angiography, and conventional digital subtraction angiography (DSA) was performed in 32 consecutive patients. The first dynamic 3D contrast-enhanced T1-weighted acquisition was individually timed after injection of a bolus of gadolinium-based contrast agent to obtain an arterial phase image followed by two sequential venous phase images (three 18-second acquisitions). Two readers independently interpreted and graded the MR images for diagnostic confidence and depiction of aneurysms and subsequently compared them with DSA images. RESULTS: Three-dimensional contrast-enhanced T1-weighted MR angiograms depicted all 23 aneurysms detected in 17 patients at DSA (mean size, 6 mm; range, 2-21 mm) with one false-positive result by one reader (sensitivity, 100%; specificity, 94%). MT TONE and phase-contrast images failed to depict one and seven aneurysms, respectively (MT TONE sensitivity of 96% and specificity of 100%, phase-contrast sensitivity of 70% and specificity of 100%). Aneurysm depiction at 3D contrast-enhanced T1-weighted MR angiography was significantly better than that at MT TONE imaging (P < .012), and that with both was significantly superior to that of phase-contrast imaging (P < .001). Differences in diagnostic confidence in the presence of an aneurysm were not significant between 3D contrast-enhanced T1-weighted and MT TONE imaging (P = .076). CONCLUSION: Dynamic 3D contrast-enhanced T1-weighted MR angiography is a fast, efficient, and minimally invasive imaging method with which to diagnose intracranial aneurysms.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 50 条
[1]   Three-dimensional gadolinium-enhanced MR angiography: Applications for abdominal imaging [J].
Glockner, JF .
RADIOGRAPHICS, 2001, 21 (02) :357-370
[2]   Pulmonary arteriovenous malformations: Three-dimensional gadolinium-enhanced MR angiography - Initial experience [J].
Maki, DD ;
Siegelman, ES ;
Roberts, DA ;
Baum, RA ;
Gefter, WB .
RADIOLOGY, 2001, 219 (01) :243-246
[3]   Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography [J].
Davis, CP ;
Hany, TF ;
Wildermuth, S ;
Schmidt, M ;
Debatin, JF .
RADIOGRAPHICS, 1997, 17 (05) :1061-1077
[4]   Gadolinium-enhanced three-dimensional MR angiography of Takayasu arteritis [J].
Nastri, MV ;
Baptista, LPS ;
Baroni, RH ;
Blasbalg, R ;
de Avila, LF ;
Leite, CC ;
de Castro, CC ;
Cerri, GG .
RADIOGRAPHICS, 2004, 24 (03) :773-786
[5]   Gadolinium-enhanced three-dimensional MR angiography in jugular phlebectasia and aneurysm [J].
Fitoz, S ;
Atasoy, Ç ;
Yagmurlu, A ;
Erden, I ;
Akyar, S .
CLINICAL IMAGING, 2001, 25 (05) :323-326
[6]   Thoracic aorta: Comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging [J].
Krinsky, GA ;
Rofsky, NM ;
DeCorato, DR ;
Weinreb, JC ;
Earls, JP ;
Flyer, MA ;
Galloway, AC ;
Colvin, SB .
RADIOLOGY, 1997, 202 (01) :183-193
[7]   Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography [J].
Goldfarb, JW ;
Edelman, RR .
RADIOLOGY, 1998, 206 (03) :830-834
[8]   Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation [J].
Earls, JP ;
DeSena, S ;
Bluemke, DA .
RADIOLOGY, 1998, 209 (03) :844-849
[9]   Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography [J].
DeCobelli, F ;
Vanzulli, A ;
Sironi, S ;
Mellone, R ;
Angeli, E ;
Venturini, M ;
Garancini, MP ;
Quartagno, R ;
Bianchi, G ;
DelMaschio, A .
RADIOLOGY, 1997, 205 (03) :689-695
[10]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280