Application of MFL on Girth-Weld Defect Detection of Oil and Gas Pipelines

被引:19
作者
Dai, L. S. [1 ]
Feng, Q. S. [2 ]
Sutherland, J. [3 ]
Wang, T. [2 ]
Sha, S. Y. [2 ]
Wang, F. X. [4 ]
Wang, D. P. [1 ]
机构
[1] Tianjin Univ, Sch Mat Sci & Engn, Tianjin 300072, Peoples R China
[2] PetroChina Pipeline Co, 408 Xinhua Rd, Langfang 065000, Peoples R China
[3] Baker Hughes, 17021 Aldine Westfield Rd, Houston, TX 77073 USA
[4] PetroChina Pipeline R&D Ctr, 51 Jinguang Rd, Langfang 065000, Peoples R China
关键词
Girth weld (GW); Defect; Magnetic flux leakage 4 (MFL4); Pull-through test; Excavation;
D O I
10.1061/(ASCE)PS.1949-1204.0000497
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Globally, the integrity of girth weld (GW) of oil and gas pipelines has increased as a concern due to failures with high consequences. A primary integrity issue to pipelines considers defects originating during field construction but over time may also be subject to external loads and stresses due to earth movement. GW defects in newly built pipelines are also assumed to exist but would be much smaller in size, and more difficult to detect, which motivated the investigation into minimum defect detection levels of the inspection technologies. Research objectives of this paper are to characterize and summarize the applicability of inline inspection (ILI) technology of magnetic flux leakage 4 (MFL4) for inspection of defects related to pipeline GWs. Pull-through test and infield site excavations of operational pipelines have been collected and used for detection, internal/external (int/ext) identification, and sizing quantification. It can be concluded that the MFL4 technique is generally sensitive to lack of fusion or penetration, deep undercut, local thinning with results of both pull test and field data; while not sensitive to closed or very narrow small dimension cracks (narrower than 1 mm, less than 2 mm deep) as was observed in this study. (c) 2020 American Society of Civil Engineers.
引用
收藏
页数:8
相关论文
共 18 条
[1]  
Amend B., 2010, VINTAGE GIRTH WELD D
[2]  
Bain A, 2010, P 22 PIP PIGG INT MA
[3]   Three-axial MFL inspection in pipelines for defect imaging using a hybrid inversion procedure [J].
Chen, Junjie .
Insight: Non-Destructive Testing and Condition Monitoring, 2016, 58 (06) :302-307
[4]   Literature Review: Theory and Application of In-Line Inspection Technologies for Oil and Gas Pipeline Girth Weld Defection [J].
Feng, Qingshan ;
Li, Rui ;
Nie, Baohua ;
Liu, Shucong ;
Zhao, Lianyu ;
Zhang, Hong .
SENSORS, 2017, 17 (01)
[5]  
Kim Y., 2019, P 2019 IEEE STUD C E
[6]   Sizing limits of metal loss anomalies using tri-axial MFL measurements: A model study [J].
Kopp, Gerhard ;
Willems, Herbert .
NDT & E INTERNATIONAL, 2013, 55 :75-81
[7]  
Li H., 2005, OIL GAS STORAGE TRAN, V24, P1, DOI [10.3969/j.issn.1000-8241-D.2005.z1.001, DOI 10.3969/J.ISSN.1000-8241-D.2005.Z1.001]
[8]  
Ma J., 2012, DEV VINTAGE GIRTH WE
[9]  
Martin P., 2011, VINTAGE WELD DEFECT
[10]  
PHMSA (Pipeline and Hazardous Materials Safety Administration), 2020, PIP INC FLAGG FIL