Air ventilation impacts of the "wall effect" resulting from the alignment of high-rise buildings

被引:136
作者
Yim, S. H. L. [1 ]
Fung, J. C. H. [1 ,2 ]
Lau, A. K. H. [1 ]
Kot, S. C. [3 ]
机构
[1] Hong Kong Univ Sci & Technol, Inst Environm, Kowloon, Hong Kong, Peoples R China
[2] Hong Kong Univ Sci & Technol, Dept Math, Hong Kong, Hong Kong, Peoples R China
[3] Hong Kong Univ Sci & Technol, Dept Mech Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Air ventilation; Wall effect; Retention time; Velocity ratio; Pollutant dispersion; Urban air quality; PEDESTRIAN WIND ENVIRONMENT; URBAN STREET CANYONS; POLLUTANT DISPERSION; COOPERATIVE PROJECT; CFD PREDICTION; TUNNEL; MODEL; VALIDATION; SIMULATION; QUALITY;
D O I
10.1016/j.atmosenv.2009.07.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study is to investigate the air ventilation impacts of the so called "wall effect" caused by the alignment of high-rise buildings in complex building clusters. The research method employs the numerical algorithm of computational fluid dynamics (CFD - FLUENT) to simulate the steady-state wind field in a typical Hong Kong urban setting and investigate pollutant dispersion inside the street canyon utilizing a pollutant transport model. The model settings of validation study were accomplished by comparing the simulation wind field around a single building block to wind tunnel data. The results revealed that our model simulation is fairly close to the wind tunnel measurements. In this paper, a typical dense building distribution in Hong Kong with 2 incident wind directions (0 degrees and 22.5 degrees) is studied. Two performance indicators are used to quantify the air ventilation impacts, namely the velocity ratio (VR) and the retention time (T-r) of pollutants at the street level. The results indicated that the velocity ratio at 2 m above ground was reduced 40% and retention time of pollutants increased 80% inside the street canyon when high-rise buildings with 4 times height of the street canyon were aligned as a "wall" upstream. While this reduction of air ventilation was anticipated, the magnitude is significant and this result clearly has important implications for building and urban planning. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4982 / 4994
页数:13
相关论文
共 50 条
  • [1] The impacts of introducing voids combinations on indoor ventilation performance in high-rise residential buildings
    Laloui, Hamza
    Abdul Majid, Noor Hanita
    Sanusi, Aliyah Nur Zafirah
    ENGINEERING CONSTRUCTION AND ARCHITECTURAL MANAGEMENT, 2022, 29 (07) : 2736 - 2759
  • [2] Investigation of mechanical ventilation for cooling in high-rise buildings
    Sha, Haohan
    Qi, Dahai
    ENERGY AND BUILDINGS, 2020, 228
  • [3] Air pollutant dispersion around high-rise buildings due to roof emissions
    Guo, Guang Ze
    Yu, Yong
    Kwok, K. C. S.
    Zhang, Yu
    BUILDING AND ENVIRONMENT, 2022, 219
  • [4] Ventilation strategy and air change rates in idealized high-rise compact urban areas
    Hang, Jian
    Li, Yuguo
    BUILDING AND ENVIRONMENT, 2010, 45 (12) : 2754 - 2767
  • [5] Ventilation Systems to Prevent Food Odour Spread in High-rise Residential Buildings
    Kim, Taeyeon
    Park, Beung-Yong
    Cheong, Chang Heon
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (02) : 304 - 316
  • [6] Design optimization and field demonstration of natural ventilation for high-rise residential buildings
    Zhou, Chaobin
    Wang, Zhiqiang
    Chen, Qingyan
    Jiang, Yi
    Pei, Jingjing
    ENERGY AND BUILDINGS, 2014, 82 : 457 - 465
  • [7] Ventilation Strategies for Mitigating Indoor Air Pollutants in High-Rise Residential Buildings: A Case Study in Dubai
    Jung, Chuloh
    Mahmoud, Naglaa Sami Abdelaziz
    ATMOSPHERE, 2023, 14 (11)
  • [8] A study of the "wall effect" caused by proliferation of high-rise buildings using GIS techniques
    Wong, Man Sing
    Nichol, Janet
    Ng, Edward
    LANDSCAPE AND URBAN PLANNING, 2011, 102 (04) : 245 - 253
  • [9] Energy and Fire Safety Performance of Atrium Ventilation in High-rise Buildings
    Sha, Haohan
    Qi, Dahai
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4004 - 4009
  • [10] Influence of placement and height of high-rise buildings on wind pressure distribution and natural ventilation of low- and medium-rise buildings
    Kuznetsov, Sergey
    Butova, Alla
    Pospisil, Stanisla
    INTERNATIONAL JOURNAL OF VENTILATION, 2016, 15 (3-4) : 253 - 266