Single-stage balloon valvuloplasty for critical pulmonary valve stenosis in the neonate

被引:0
|
作者
Thanopoulos, B
Triposkiadis, F
Tsaousis, GS
机构
[1] Department of Pediatric Cardiology, Aghia Sophia Athens Children's Hosp., Goudi 11527, Athens
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1997年 / 40卷 / 03期
关键词
pulmonary stenosis; balloon dilation; neonate;
D O I
10.1002/(SICI)1097-0304(199703)40:3<322::AID-CCD25>3.0.CO;2-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Balloon valvuloplasty (BV) in neonates with critical pulmonary valve stenosis (CPVS) is limited by technical considerations, mainly the difficulty of traversing the stenotic valve, To simplify the procedure we used a 46 Cobra Type I catheter to cross the pulmonary valve (PV) without the aid of a guidewire, and performed single-stage BV, using low-profile balloons, in 12 neonates with CPVS, Procedure and total fluoroscopy times were 69+/-33 min (42-125 min) and 34+/-19 min (20-58 min), respectively, Following BV, right ventricular systolic pressure (RVSP) decreased from 102+/-17 mm Hg to 56+/-15 mm Hg (p <0.001); and the ratio of RVSP to aortic systolic pressure decreased from 1.39+/-0.22 to 0.73+/-0.21 (p <0.001). No significant complications were observed, BV failed in two patients, who subsequently had surgery, At follow-up (a mean of 19 months), Doppler gradient was 19+/-12 mm Hg (0-50 mm Hg). BV was repeated in one patient. We conclude that in neonates with CPVS, the use of the 4F Cobra type I catheter facilitates crossing of the PV and allows performance of BV in a single stage; this enhances safety and time-efficiency, and shortens exposure to radiation. (C) 1997 Wiley-Liss, Inc.
引用
收藏
页码:322 / 325
页数:4
相关论文
共 50 条
  • [1] Balloon valvuloplasty for critical pulmonary valve stenosis in newborn: A single center ten-year experience
    Alsawah, Gehan Attia
    Hafez, Mona M.
    Matter, Mohamed
    Abo-Haded, Hany M.
    Rakha, Shaimaa
    Almarsafawy, Hala
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2016, 43 : 127 - 131
  • [2] Device closure of an atrial septal defect following successful balloon valvuloplasty in a neonate with critical pulmonary valve stenosis and persistent cyanosis
    Nugent, AW
    Menahem, S
    Goh, TH
    Butt, W
    PEDIATRIC CARDIOLOGY, 2000, 21 (02) : 170 - 171
  • [3] Balloon pulmonary valvuloplasty in neonates with critical pulmonary stenosis: Jugular or femoral
    Hoetama, Erick
    Prakoso, Radityo
    Roebiono, Poppy Surwianti
    Sakidjan, Indriwanto
    Kurniawati, Yovi
    Siagian, Sisca Natalia
    Lelya, Olfi
    Rahajoe, Anna Ulfah
    Harimurti, Ganesja Moelia
    Lilyasari, Oktavia
    ANNALS OF PEDIATRIC CARDIOLOGY, 2020, 13 (01) : 11 - 15
  • [4] BALLOON VALVOPLASTY OF CRITICAL AORTIC AND PULMONARY STENOSIS IN THE PREMATURE NEONATE
    TOMETZKI, AJP
    GIBBS, JL
    WEIL, J
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1991, 30 (02) : 248 - 249
  • [5] Predictors for long-term outcome of pulmonary valve perforation and balloon valvuloplasty in neonates with critical pulmonary valve stenosis or pulmonary valve atresia with intact ventricular septum
    Abu-Tair, Tariq
    Willershausen, Ines
    Friedmann, Melanie
    Rubarth, Kai
    Weigelt, Annika
    Martin, Claudia
    Dittrich, Sven
    Kampmann, Christoph
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2025, 12
  • [6] Right Ventricular Functions in Patients Undergone Balloon Valvuloplasty for Isolated Pulmonary Valve Stenosis
    Katipoglu, Nagehan
    Kucuk, Mehmet
    Mese, Timur
    Ozdemir, Rahmi
    Yilmazer, Murat Muhtar
    Karaarslan, Utku
    IZMIR DR BEHCET UZ COCUK HASTANESI DERGISI, 2019, 9 (01): : 34 - 40
  • [7] Long-term results of percutaneous balloon valvuloplasty in neonatal critical pulmonary valve stenosis: a 20-year, single-centre experience
    Loureiro, Petra
    Cardoso, Barbara
    Gomes, Ines B.
    Martins, Jose F.
    Pinto, Fatima F.
    CARDIOLOGY IN THE YOUNG, 2017, 27 (07) : 1314 - 1322
  • [8] Pulmonary balloon valvuloplasty in a pregnant woman with severe pulmonary stenosis
    Sener, Yusuf Ziya
    Sahiner, Levent
    Oksul, Metin
    Kaya, Ergun Baris
    Aytemir, Kudret
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2019, 47 (07): : 619 - 621
  • [9] EFFICACY OF BALLOON VALVULOPLASTY IN TREATING MILD PULMONARY STENOSIS
    WANG, JK
    LUE, HC
    WU, MH
    YOUNG, ML
    ACTA CARDIOLOGICA, 1992, 47 (04) : 349 - 355
  • [10] Restenosis after balloon valvuloplasty in a dog with pulmonary stenosis
    Sunahara, Hiroshi
    Fujii, Yoko
    Sugimoto, Keisuke
    Aoki, Takuma
    Sugahara, Gou
    Shirota, Kinji
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2015, 77 (01) : 95 - 99