Energetic and exergetic analysis of solar-powered lithium bromide-water absorption cooling system

被引:64
作者
Kerme, Esa Dube [1 ]
Chafidz, Achmad [2 ]
Agboola, O. Philips [1 ]
Orfi, Jamel [1 ]
Fakeeha, Anis H. [3 ]
Al-Fatesh, Ahmed S. [3 ]
机构
[1] King Saud Univ, Dept Mech Engn, Coll Engn, POB 800, Riyadh 11421, Saudi Arabia
[2] Univ Negeri Semarang, Dept Chem Engn, Semarang 50229, Indonesia
[3] King Saud Univ, Dept Chem Engn, Coll Engn, POB 800, Riyadh 11421, Saudi Arabia
关键词
Absorption cooling; Solar collector; Coefficient of performance; Exergetic efficiency; Exergy destruction; Fuel depletion ratio; Improvement potential; MEMBRANE DISTILLATION; PERFORMANCE; SIMULATION; RADIATION; DESIGN; SINGLE;
D O I
10.1016/j.jclepro.2017.03.060
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a comprehensive thermodynamic modeling of the solar-powered lithium bromide-water (LiBr-H2O) absorption chiller system. The study examined the influence of the solar collector types on the collector efficiency and the useful heat gain by the collector for the best performance. The study also analyzed the effects of generator inlet temperature, effectiveness of the solution heat exchanger and the pump mass flow rate on the energetic and exergetic performance of the chiller system. The examined performance parameters were coefficient of performance, exergetic efficiency, exergy destruction, fuel depletion ratio and improvement potential. The study revealed that 'evacuated selective surface' collector type has resulted in higher efficiency and more useful heat gain than the single and double glazed collector types. Additionally, the increase in the heat exchanger effectiveness improved the system performance, while the increase in the pump mass flow rate reduced the chiller performance. Furthermore, the result also indicated that the main source of the exergy destruction is the solar collector. In the solar collector, 71.9% of the input exergy was destroyed which accounted for 84% of the total exergy loss. Additionally, 7.1% of the inlet exergy was lost in the generator which was equivalent to 8.3% of the total exergy loss. The overall exergetic improvement potential of the system was approximately 84.7%. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:60 / 73
页数:14
相关论文
共 37 条
  • [1] Adjustment factors for the ASHRAE clear-sky model based on solar-radiation measurements in Riyadh
    Al-Sanea, SA
    Zedan, MF
    Al-Ajlan, SA
    [J]. APPLIED ENERGY, 2004, 79 (02) : 215 - 237
  • [2] [Anonymous], 2013, SOLAR ENERGY ENG PRO, DOI DOI 10.1016/B978-0-12-374501-9.00014-5
  • [3] Feasibility of solar absorption air conditioning in Tunisia
    Balghouthi, M.
    Chahbani, M. H.
    Guizani, A.
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (09) : 1459 - 1470
  • [4] Bejan A, 1996, Thermal Design and Optimization
  • [5] Design and fabrication of a portable and hybrid solar-powered membrane distillation system
    Chafidz, Achmad
    Kerme, Esa D.
    Wazeer, Irfan
    Khalid, Yasir
    Ajbar, Abdelhamid
    Al-Zahrani, Saeed M.
    [J]. JOURNAL OF CLEANER PRODUCTION, 2016, 133 : 631 - 647
  • [6] Portable and integrated solar-driven desalination system using membrane distillation for arid remote areas in Saudi Arabia
    Chafidz, Achmad
    Al-Zahrani, Saeed
    Al-Otaibi, Mansour N.
    Hoong, Choo F.
    Lai, Tan F.
    Prabu, Manoharan
    [J]. DESALINATION, 2014, 345 : 36 - 49
  • [7] ABSORPTION OF RADIATION IN SOLAR STILLS
    COOPER, PI
    [J]. SOLAR ENERGY, 1969, 12 (03) : 333 - &
  • [8] Design and performance of solar powered absorption cooling systems in office buildings
    Eicker, Ursula
    Pietruschka, Dirk
    [J]. ENERGY AND BUILDINGS, 2009, 41 (01) : 81 - 91
  • [9] Economical comparison between a solar-powered vapour absorption air-conditioning system and a vapour compression system in the Middle East
    Elsafty, A
    Al-Daini, AJ
    [J]. RENEWABLE ENERGY, 2002, 25 (04) : 569 - 583
  • [10] Ergul E., 1991, SIMULATION SOLAR AID