Performance analysis of megahertz-band transformer taking account of displacement current

被引:0
|
作者
Mitsutake, Yoshio [1 ]
Hirata, Katsuhiro [1 ]
Niwa, Kota [1 ]
Ishihara, Yoshiyuki [1 ]
机构
[1] Osaka Univ, Osaka, Japan
关键词
transformer; finite element method; displacement current;
D O I
10.1002/eej.20490
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In designing power electronics devices, it is very important to have accurate waveforms of input/output voltage and current in order to estimate the efficiency and the power factor. Therefore, it is useful to study the effective dynamic analysis method through a numerical approach. In these computations, the displacement current is ignored because the frequency range is lower than the megahertz range, and the necessity of taking into account the displacement current is thought to be uncertain when the transformer is operated at a frequency exceeding I MHz. This paper describes the effect of the displacement current on dynamic performances of a megahertz-band transformer. It is found that the influence of displacement current on output power is about 2% based on the results of computation, and becomes stronger as the frequency increases. The validity of the computation is verified through a comparison with the measured results. (c) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:60 / 67
页数:8
相关论文
共 6 条
  • [1] Numerical modelling of magnetic characteristics of ferrite core taking account of both eddy current and displacement current
    Ghosh, Mohendro Kumar
    Gao, Yanhui
    Dozono, Hiroshi
    Muramatsu, Kazuhiro
    Guan, Weimin
    Yuan, Jiaxin
    Tian, Cuihua
    Chen, Baichao
    HELIYON, 2019, 5 (08)
  • [2] Analysis of the Mutual Inductance in Current Transformers Taking Primary Conductors Eccentricity Into Account
    Faria, J. Brandao
    Machado, V. Malo
    Neves, M. Guerreiro
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (06) : 1719 - 1725
  • [3] Method of nonlinear magnetic field analysis taking into account eddy current in laminated core
    Muramatsu, K
    Okitsu, T
    Fujitsu, H
    Shimanoe, F
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (02) : 896 - 899
  • [4] Analysis of magnetic characteristics of permanent magnet assembly for MRI devices taking account of hysteresis and eddy current
    Miyata, K
    Ohashi, K
    Takahashi, N
    Ukita, H
    IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) : 3556 - 3559
  • [5] Analysis of transformer differential protection performance under geomagnetically induced current conditions
    Ahmadzadeh-Shooshtari, Babak
    Rezaei-Zare, Afshin
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 194
  • [6] The no-load performance of 3-phase transformer bank under direct-current bias based on the 3D transient analysis
    Yao, YY
    Xie, DX
    Bai, BD
    Zeng, LS
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 281 - 284